CHAPTER 5 Technical Specifications

MIC412TI and TF Dual Optical/Thermal PTZ Camera

CAMERA MODULE (OPTICAL)

 

Image sensor

1/4” EXview CCD

Picture elements

380K NTSC / 440K PAL (WIDE)

Horizontal resolution

WDR 36x modules 530 TVL NTSC / PAL

Filter

Automatic mechanical IR cut filter

Focus system

Auto or manual

Iris

Auto or manual with slow shutter integration

 

modes

Synchronisation

Internal / External (V-Lock)

Signal/Noise ratio

50 dB or more

Back Light Compensation (BLC)

On/Off

White balance

Automatic

Automatic Gain Control (AGC)

-3 to -28 dB, 2dB steps

Aperture control

16 Steps

36x optical zoom module

 

Lens

F=3.4 mm (WIDE) to 122.4 mm (TELE),

 

F1.6 to F4.5

Zoom

36x optical (12x digital)

Angle of view

57.8º (WIDE end) to 1.7º (TELE end)

Minimum illumination

1.4 lux (1/60s NTSC, 1/50s PAL, F1.6,

 

50 IRE),

 

0.1 lux (1/4s NTSC, 1/3s PAL, F1.6,

 

50 IRE)

 

0.01 lux (1/4s NTSC, 1/3s PAL, ICR ON)

Shutter speed

NTSC: 1/4 to 1/10,000s (22 steps)

 

PAL: 1/3 to 1/10,000s (20 steps)

 

1/10,000s (20 steps) PAL

 

EN 51

CAMERA MODULE (THERMAL)

 

Lens

50mm

Image sensor

Focal Plane Array (FPA), un-cooled

 

Vanadium Oxide microbolometer

 

(MIC412TI: 7.5Hz NTSC, 8.3Hz PAL)

 

(MIC412TF: US export licence required:

 

30Hz NTSC, 25Hz PAL)

Picture elements

324 (H) x 256 (V)

Spatial resolution

0.760 mrad with 50 mm lens

Field of view

14° (H) x 11° (V) with 50 mm lens

Focus

Factory-set at infinity focus

Detection range

Human: 780 m (2559 ft)

 

Object : 2.2 km (7218 ft)

Spectral response

7.5 to 13.5μm

Thermal sensitivity

<85 mK at F1.6

Features

White hot, black hot and false colour

OPERATIONAL*

 

E-flip

Yes

Manual flip

Yes

Presets

64 telemetry presets accurate to less than

 

0.1° utilising resolver technology (using FV

 

protocol, 10 camera set-up presets to allow

 

ANPR, colour correction etc.)

Preset tours

6 tours, each with up to 32 presets

Sector titles

Yes (64 sectors), 20 characters per title

Preset titles

20 character caption for each of the 64

 

presets

Home position

Yes (preset 1 or tour)

COMMUNICATION & PROTOCOLS

 

Communication

RS485 / RS422

Control Protocol

Refer to protocol list on datasheet

Bosch Security Systems

Issue 8

Image 51
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Appendices Glossary of TermsIntroduction MIC412 Camera Versions MIC 412 Power Supply Unit Versions and OptionsWiper FeaturesPackaging Contents MIC 412 OptionsInstallation Environment Bosch Security Systems Issue Key to MIC-PMB drawing Associated Equipment and Typical InstallationsInstallation Instructions Hardware InstallationEarthing of the MIC 412 camera Lightning ProtectionElectrical Connections PCB Earth Link MIC 412TI and MIC 412TF Power Supply UnitsPower Supply Layout and Connections MIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-ULTable D -Telemetry Connections to HD3, HD4 and HD5 HD3Rating for 115v Primary Terminal Box ConnectorTerminal Box ID Marking Fuse Fuse function Rating for 240v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the KK systems K2-ADE RS232 to RS485/422 Adaptor Connecting the MIC 412 to the PCConnecting the Greenwich Adaptor Table G Connecting the Greenwich AdaptorTable I Camera Interface Control Settings DIP Switch Connecting the MIC-USB485CVTR, USB to RS485 ConverterCamset Tabs Wire RS485 Wire RS422 HD4 or HD5 MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls Boot MessagesMIC Settings Commissioning the MIC412 through Universal CamsetCamset Settings Manual Control Pan, Tilt and Zoom Controls Auxiliaries Preset PositionsIris Controls Focus ControlsPreset Tours Tour ControlsPattern Tours Clear MIC SetupsSoft Stops and Non Dwell Zones Non-Dwell ZoneGeneral Settings Other controls Auto Home ControlsDefault Settings Relay State, Activation and Re-arm Multi Alarm SettingsLearn Alarm Positions Frame Integration SettingsPrivacy Controls Privacy and CaptionsPrivacy Calibration Captions Gain and Auto Gain Modes FFC Mode and SettingsThermal Shutter Open/CloseClear All Statistics Advanced SettingsTemperature and Humidity TimersUpload Eeprom From File Eeprom CopierOnly Download Eeprom To FileMatrix Controls Manual and Preset / Goto ControlsPOT Test Menu Controls Panasonic OnlyVisible Traces Pot Test ControlsComms Pot Test ResultsMouse Point Values Send Direct Command Cam Comms Communications TestingAlarms MIC CommsSonySet Controls Get Preset from MICSend Preset to MIC Sony SetClear Table Execute this PresetLoad Table from File to MIC Save Table from MIC to FileTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Learning a preset Help MIC412 Preset Codes for the Thermal ImagerBosch Protocol Aux Number Aux On Function Aux Off Function Go to a preset36x optical zoom module MIC412TI and TF Dual Optical/Thermal PTZ CameraConnectivity Appendix a Sonyset Camera Commands Dimension DrawingsMIC 412 models Upright 90 Dimension Drawings Pelco Appendix B Protocol Preset CodesWashwipeonpreset Washwipeoffpreset Vision Special Setup PresetsAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Bosch Security Systems Inc Contact AmericasEurope, Middle East, Africa Asia-PacificBosch Security Systems, Inc