Bosch Appliances MIC412 Communications Testing, MIC Comms, Cam Comms, Alarms, Detect All MICs

Page 43

MIC412TI and MIC412TF Camera Installation and Operation Manual

EN 43

Communications Testing

Communications Testing enables the user to test the quality of the communications link to the MIC. This does require 2 way comms for any of the below options. Use the Cancel button at any time to stop the testing process.

MIC Comms

To initiate, select the MIC Comms radio button and press Test. This will repeatedly query the MIC for a set response the number of times of which is defined by the Test Repetitions input box. If the response is valid and within the correct time frame then it is logged as a pass. No response or a late response is flagged as a time out and short or incorrect data is classed as a fail. The results of this are continually displayed in the small window directly below the Test button. Any faults along the length of the comms lines will normally result in fails or timeouts dependant on the severity of the problem.

Cam Comms

Starting this is as with MIC Comms but by selecting the Sony Cam Comms radio instead. So long as the MIC Comms are 100% reliable this will return the reliability of the comms to the Sony Module inside the MIC, again returning passes, fails and time outs in the same frame. If these are intermittent, please contact Forward Vision for advice.

Alarms

This test monitors the state of the 8 alarm inputs if applicable, printing if they are turned On or Off continually throughout the test in the larger of the 2 results windows. The test is started by selecting Alarms from the options and pressing Test.

Detect All MICs

This sends out a request to each MIC address for its Software Version printing the Response and the respective address in the large results box. This can be used in conjunction with setting a site of multiple MICs all to address 0 (random address) to then find what address each is on and therefore regain control.

Bosch Security Systems

Issue 8

Image 43
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Appendices Glossary of TermsIntroduction MIC412 Camera Versions MIC 412 Power Supply Unit Versions and OptionsWiper FeaturesPackaging Contents MIC 412 OptionsInstallation Environment Bosch Security Systems Issue Key to MIC-PMB drawing Associated Equipment and Typical InstallationsInstallation Instructions Hardware InstallationLightning Protection Earthing of the MIC 412 cameraElectrical Connections PCB Earth Link MIC 412TI and MIC 412TF Power Supply UnitsPower Supply Layout and Connections MIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-ULTable D -Telemetry Connections to HD3, HD4 and HD5 HD3Rating for 115v Primary Terminal Box ConnectorTerminal Box ID Marking Fuse Fuse function Rating for 240v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the KK systems K2-ADE RS232 to RS485/422 Adaptor Connecting the MIC 412 to the PCConnecting the Greenwich Adaptor Table G Connecting the Greenwich AdaptorConnecting the MIC-USB485CVTR, USB to RS485 Converter Table I Camera Interface Control Settings DIP SwitchCamset Tabs Wire RS485 Wire RS422 HD4 or HD5 MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls Boot MessagesMIC Settings Commissioning the MIC412 through Universal CamsetCamset Settings Manual Control Pan, Tilt and Zoom Controls Auxiliaries Preset PositionsIris Controls Focus ControlsTour Controls Preset ToursPattern Tours Clear MIC SetupsSoft Stops and Non Dwell Zones Non-Dwell ZoneGeneral Settings Other controls Auto Home ControlsDefault Settings Relay State, Activation and Re-arm Multi Alarm SettingsLearn Alarm Positions Frame Integration SettingsPrivacy Controls Privacy and CaptionsPrivacy Calibration Captions Gain and Auto Gain Modes FFC Mode and SettingsThermal Shutter Open/CloseClear All Statistics Advanced SettingsTemperature and Humidity TimersUpload Eeprom From File Eeprom CopierOnly Download Eeprom To FileMatrix Controls Manual and Preset / Goto ControlsPOT Test Menu Controls Panasonic OnlyVisible Traces Pot Test ControlsPot Test Results CommsMouse Point Values Send Direct Command Cam Comms Communications TestingAlarms MIC CommsSonySet Controls Get Preset from MICSend Preset to MIC Sony SetClear Table Execute this PresetLoad Table from File to MIC Save Table from MIC to FileTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Learning a preset Help MIC412 Preset Codes for the Thermal ImagerBosch Protocol Aux Number Aux On Function Aux Off Function Go to a preset36x optical zoom module MIC412TI and TF Dual Optical/Thermal PTZ CameraConnectivity Dimension Drawings Appendix a Sonyset Camera CommandsMIC 412 models Upright 90 Dimension Drawings Pelco Appendix B Protocol Preset CodesWashwipeonpreset Washwipeoffpreset Vision Special Setup PresetsAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Bosch Security Systems Inc Contact AmericasEurope, Middle East, Africa Asia-PacificBosch Security Systems, Inc