Bosch Appliances MIC412 HD4 or HD5, MIC-USB485CVTR and Universal Camset Software Installation

Page 22

MIC412TI and MIC412TF Camera Installation and Operation Manual

The table overleaf shows how the screw terminal connections on the MIC- USB485CVTR connect to the MIC power supply depending upon the protocol and selected communication mode you may only need a 2 wire configuration.

CAUTION: Should be taken to avoid earth loops when connecting 0v from the converter to GND terminal in the MIC

Table J – MIC-USB485CVTR Connection Table and Diagram

 

 

 

 

 

 

 

 

 

 

 

 

Converter Output

 

 

MIC Power Supply

 

 

Communication Mode

 

 

 

 

 

 

Telemetry Header

 

 

 

 

 

 

 

 

 

(HD4 or HD5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RxB / Rx -

 

 

TxB

 

 

Full Duplex (4-wire only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RxA / Rx +

 

 

TxA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND / 0V

 

 

GND

 

 

Shield (always)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TxA / Tx -

 

 

RxA

 

 

Simplex

 

 

 

 

 

 

 

 

 

Half Duplex (2-wire)

 

 

 

 

 

 

 

 

 

Full Duplex (4-wire)

 

 

 

TxB / Tx +

 

 

RxB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 22

MIC-USB485CVTR and Universal Camset Software Installation

Universal Camset comes with WHQL certified drivers for the MIC-USB485CVTR that must be installed prior to connecting the converter to the PC.

To install the drivers please do the following:-

1.Locate the USB DRIVERS.EXE in the Universal Camset Folder, double click to begin and follow the on screen instructions to install; these are the required drivers for using the MIC-USB485CTR.

2.Locate the CAMSET INSTALLER.MSI and then double click to begin, follow the on screen instructions to install.

3.Once installed a Universal Camset Icon will appear on your PC Desktop.

4.When opened the Universal Camset will display the Standard Controls Tab as shown overleaf.

Providing the USB drivers have been installed successfully, you can then plug the MIC-USB485CVTR into a PC via the USB port. If your converter is being plugged in for the first time your system should recognise the device and inform you that the hardware has been installed successfully.

The MIC-USB485CVTR should appear in the Comm Port selection list as USB and as a virtual Comm Port, e.g “comm2” (for legacy support). Universal Camset has been optimised to work with this converter in USB mode; therefore users should select “USB” for maximum functionality and reliability.

The MIC-USB485CVTR has a status LED indicating its current state, by sending a manual command e.g Left or Right; you should see the LED flash. Transmitted data from the converter is indicated by a red flashing LED flash and upon receiving data a green LED will flash.

Bosch Security Systems

Issue 8

Image 22
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsMIC 412 Options FeaturesPackaging Contents WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsLightning Protection Earthing of the MIC 412 cameraElectrical Connections MIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL MIC 412TI and MIC 412TF Power Supply UnitsPower Supply Layout and Connections PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Rating for 240v Primary Terminal Box ConnectorTerminal Box ID Marking Fuse Fuse function Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Table G Connecting the Greenwich Adaptor Connecting the MIC 412 to the PCConnecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorConnecting the MIC-USB485CVTR, USB to RS485 Converter Table I Camera Interface Control Settings DIP SwitchCamset Tabs Wire RS485 Wire RS422 MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Commissioning the MIC412 through Universal Camset Boot MessagesMIC Settings Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Focus Controls Preset PositionsIris Controls AuxiliariesTour Controls Preset ToursPattern Tours Non-Dwell Zone MIC SetupsSoft Stops and Non Dwell Zones ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Frame Integration Settings Multi Alarm SettingsLearn Alarm Positions Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions Shutter Open/Close FFC Mode and SettingsThermal Gain and Auto Gain ModesTimers Advanced SettingsTemperature and Humidity Clear All StatisticsDownload Eeprom To File Eeprom CopierOnly Upload Eeprom From FileMenu Controls Panasonic Only Manual and Preset / Goto ControlsPOT Test Matrix ControlsPot Test Controls Visible TracesPot Test Results CommsMouse Point Values Send Direct Command MIC Comms Communications TestingAlarms Cam CommsSony Set Get Preset from MICSend Preset to MIC SonySet ControlsSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity Dimension Drawings Appendix a Sonyset Camera CommandsMIC 412 models Upright 90 Dimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncBosch Security Systems, Inc