Bosch Appliances MIC412 operation manual Connectivity

Page 52

MIC412TI and MIC412TF Camera Installation and Operation Manual

 

 

EN 52

CONNECTIVITY

 

Dimensions (W x H x D)

267 x 445 x 200 mm, including 4-in. PCD

 

 

 

 

base

Video

Single coaxial via composite cable

 

 

(10.51 x 17.52 x 7.87 ft)

Telemetry

Twisted pair. Simplex, half and full duplex

Weight

9.5 kg (20.94 lb), including 4-in. PCD base

 

operation via composite cable

 

 

 

Power

Via composite cable

ENVIRONMENTAL

 

ALARMS

 

Operational temperature

-40°C to +50°C (-40°F to +122°F)

Alarm inputs

1 x tamper input (additional inputs possible

Weather proofing

IP68 (1 m submission for 24 hrs)

 

 

 

 

with optional alarm card in PSU)

ELECTRICAL

 

Alarm communication

Tamper switch (ground connection)

Input voltage (dual voltage)

18 VAC, ±10%, 50/60 Hz

 

 

 

 

Input current

Camera: 2 A

 

 

 

 

Heater: 1 A

MECHANICAL

 

AVAILABLE OPTIONS

 

Drive unit

Brushless Integral pan/tilt motor drive

Configuration

Upright mount or inverted mount options

Pan angle

360° continuous rotation

Camera module (optical)

36 x camera module

Pan speed

Up to 72° per second (variable)

Camera colour system

NTSC or PAL

Tilt angle

260°

Installed protocol

Choose from current protocol list

Tilt speed

0.2° to 90° per second variable

Telemetry control card

Supplied as standard

Speed control

Closed loop electronics

Window wiper

Supplied as standard

Preset accuracy

±30° (typical)

Alarm card

Optional (In PSU), factory fit

Proportional P/T to Zoom

Yes

Washer

Optional (washer bracket only)

PHYSICAL

 

ACCESSORIES

 

Construction material

Machined aluminium

Power supply

Choice of 24 VAC, 115 VAC, or 230 VAC

Viewing window glass

Tempered flat glass (optical) & germanium

Mounting hardware

Compatible with all MIC series bracketry

 

covering (thermal)

Cabling

Optional, Choose from 2 m, 10 m, 20 m or

Standard colours

Black (RAL9005), Grey (RAL7001) or

 

 

25 m versions

 

White (RAL9003)

 

 

 

Standard finish

Alocrom 1200 surface treatment with

 

 

 

 

powder coat paint

 

 

 

Window Wiper

Standard, long-life silicon

 

 

 

Bosch Security Systems

Issue 8

Image 52
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsFeatures Packaging ContentsMIC 412 Options WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsLightning Protection Earthing of the MIC 412 cameraElectrical Connections MIC 412TI and MIC 412TF Power Supply Units Power Supply Layout and ConnectionsMIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Terminal Box Connector Terminal Box ID Marking Fuse Fuse functionRating for 240v Primary Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the MIC 412 to the PC Connecting the Greenwich AdaptorTable G Connecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorConnecting the MIC-USB485CVTR, USB to RS485 Converter Table I Camera Interface Control Settings DIP SwitchCamset Tabs Wire RS485 Wire RS422 MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Boot Messages MIC SettingsCommissioning the MIC412 through Universal Camset Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Preset Positions Iris ControlsFocus Controls AuxiliariesTour Controls Preset ToursPattern Tours MIC Setups Soft Stops and Non Dwell ZonesNon-Dwell Zone ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Multi Alarm Settings Learn Alarm PositionsFrame Integration Settings Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions FFC Mode and Settings ThermalShutter Open/Close Gain and Auto Gain ModesAdvanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier OnlyDownload Eeprom To File Upload Eeprom From FileManual and Preset / Goto Controls POT TestMenu Controls Panasonic Only Matrix ControlsPot Test Controls Visible TracesPot Test Results CommsMouse Point Values Send Direct Command Communications Testing AlarmsMIC Comms Cam CommsGet Preset from MIC Send Preset to MICSony Set SonySet ControlsExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity Dimension Drawings Appendix a Sonyset Camera CommandsMIC 412 models Upright 90 Dimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncBosch Security Systems, Inc