Multi Alarm Settings

Learn Alarm Positions

Simply point the MIC400 at the position you would like it to cover when each numbered alarm is triggered and press Learn Alarm Position to set this.

Relay State, Activation and Re-arm

This function is available only to MIC-400’s with the MIC-ALM card fitted or the MIC400IR Power Supply which has Four (4) Alarm Inputs built in.

The MIC-ALM multi alarm card provides 2 output relays which can be configured to close or open on given alarm inputs. Relay 1 can be activated from either alarm inputs 1 to 4 or 1 to 8 and relay 2 with alarm inputs 5 to 8 or 1 to 8.

EN 32

The re-arm time is a time in seconds before the MIC returns to its current position and returns the relay to its prior state. The options for this are 1, 5, 10 or 60 seconds. To send the settings to the MIC select the desired options and then press Set Relays.

Lens Recalibration and Frame Integration

This section defines when and how often the Sony Optical Camera block should perform a recalibration process. The first field Inactivity defines how long in hours it should be after the last manual control command before the first recalibration should take place, and the second is a time in days between each successive recalibration from then on.

To set these enter the appropriate values in the text boxes provided and press Apply. Alternatively the Recall Now button will perform a manual recalibration.

Frame Integration Settings

This section defines the Max Gain and Min Shutter Speed parameters used by the MIC when in Auto Lowlight mode. The drop down lists provides the actual settings available in dB for gain and FPS for shutter speed. The On Screen Data auxiliary command will indicate the current frame rate if required. The values are set by simply selecting the desired option from the drop down lists.

Bosch Security Systems

Issue 8

Image 32
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsFeatures Packaging ContentsMIC 412 Options WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsElectrical Connections Earthing of the MIC 412 cameraLightning Protection MIC 412TI and MIC 412TF Power Supply Units Power Supply Layout and ConnectionsMIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Terminal Box Connector Terminal Box ID Marking Fuse Fuse functionRating for 240v Primary Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the MIC 412 to the PC Connecting the Greenwich AdaptorTable G Connecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorCamset Tabs Wire RS485 Wire RS422 Table I Camera Interface Control Settings DIP SwitchConnecting the MIC-USB485CVTR, USB to RS485 Converter MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Boot Messages MIC SettingsCommissioning the MIC412 through Universal Camset Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Preset Positions Iris ControlsFocus Controls AuxiliariesPattern Tours Preset ToursTour Controls MIC Setups Soft Stops and Non Dwell ZonesNon-Dwell Zone ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Multi Alarm Settings Learn Alarm PositionsFrame Integration Settings Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions FFC Mode and Settings ThermalShutter Open/Close Gain and Auto Gain ModesAdvanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier OnlyDownload Eeprom To File Upload Eeprom From FileManual and Preset / Goto Controls POT TestMenu Controls Panasonic Only Matrix ControlsPot Test Controls Visible TracesMouse Point Values CommsPot Test Results Send Direct Command Communications Testing AlarmsMIC Comms Cam CommsGet Preset from MIC Send Preset to MICSony Set SonySet ControlsExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity MIC 412 models Upright 90 Dimension Drawings Appendix a Sonyset Camera CommandsDimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncBosch Security Systems, Inc