Bosch Appliances MIC412 operation manual General Settings

Page 29

MIC412TI and MIC412TF Camera Installation and Operation Manual

General Settings

Pan Reverse

This will invert the pan rotation of the MIC compared to the commands from the controller. This would be used if a MIC was inverted to regain logical control.

Tilt Reverse

This will invert the tilt rotation of the MIC compared to the commands from the controller.

Image Flip

This manually inverts the image from the camera module, which may be used on an inverted camera where the head cannot be rotated through 180 degrees. Inverting the image would normally also require some modification of the control directions.

EN 29

Wash Wipe

If Wash Wipe is On then, when the Wash auxiliary is set the MIC will return to a preset Wash Position activate the washer relay in the PSU and turn on the wiper. When the auxiliary is turned off again, the MIC will return to its prior position and turn the wiper off. If Wash Wipe is Off then when the aux is activated the MIC will simply close the washer relay and remain in its current position.

Auto Alarm

This is used for both single or multi alarm functionality. With Auto Alarm on and Multi Alarm off, the MIC will monitor the tamper switch line, moving to the programmable Alarm Position when the connection is grounded. If Auto Alarm is turned off the MIC will ignore any change in status of the tamper line.

Multi Alarm

With this the user can setup a separate position for each of the 8 alarm inputs. Any given alarm input will trigger the MIC to move to the position with which it is associated. To get this functionality working both Auto Alarm and Multi Alarm should be turned on.

Photocell IR

This mode enables the user to attach an external photocell to the power supply to control the IR lamps. The device is connected to alarm input 4, meaning that when the light levels drop sufficiently alarm 4 is triggered, and instead of moving the MIC detects this as an activation signal for the lamps. When the light levels pick up again, the alarm will deactivate and the lamps will be turned off. This mode can enable the user to hide the sensor away from any large external lighting which may cause the camera to flick in and out of IR mode under Auto conditions.

Camera Power

This can be used to turn the camera module inside the MIC off as required.

Digital Zoom

This is an override for the Digital Zoom Auxiliary, meaning that if On this will allow digital zoom to be controlled by the aux state, but if off, will never allow digital zoom no matter what the state of the aux.

Bosch Security Systems

Issue 8

Image 29
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Appendices Glossary of TermsIntroduction MIC412 Camera Versions MIC 412 Power Supply Unit Versions and OptionsPackaging Contents FeaturesMIC 412 Options WiperInstallation Environment Bosch Security Systems Issue Key to MIC-PMB drawing Associated Equipment and Typical InstallationsInstallation Instructions Hardware InstallationElectrical Connections Earthing of the MIC 412 cameraLightning Protection Power Supply Layout and Connections MIC 412TI and MIC 412TF Power Supply UnitsMIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL PCB Earth LinkTable D -Telemetry Connections to HD3, HD4 and HD5 HD3Terminal Box ID Marking Fuse Fuse function Terminal Box ConnectorRating for 240v Primary Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the Greenwich Adaptor Connecting the MIC 412 to the PCTable G Connecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorCamset Tabs Wire RS485 Wire RS422 Table I Camera Interface Control Settings DIP SwitchConnecting the MIC-USB485CVTR, USB to RS485 Converter HD4 or HD5 MIC-USB485CVTR and Universal Camset Software InstallationMIC Settings Boot MessagesCommissioning the MIC412 through Universal Camset Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Iris Controls Preset PositionsFocus Controls AuxiliariesPattern Tours Preset ToursTour Controls Soft Stops and Non Dwell Zones MIC SetupsNon-Dwell Zone ClearGeneral Settings Other controls Auto Home ControlsDefault Settings Learn Alarm Positions Multi Alarm SettingsFrame Integration Settings Relay State, Activation and Re-armPrivacy Controls Privacy and CaptionsPrivacy Calibration Captions Thermal FFC Mode and SettingsShutter Open/Close Gain and Auto Gain ModesTemperature and Humidity Advanced SettingsTimers Clear All StatisticsOnly Eeprom CopierDownload Eeprom To File Upload Eeprom From FilePOT Test Manual and Preset / Goto ControlsMenu Controls Panasonic Only Matrix ControlsVisible Traces Pot Test ControlsMouse Point Values CommsPot Test Results Send Direct Command Alarms Communications TestingMIC Comms Cam CommsSend Preset to MIC Get Preset from MICSony Set SonySet ControlsLoad Table from File to MIC Execute this PresetSave Table from MIC to File Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Learning a preset Help MIC412 Preset Codes for the Thermal ImagerBosch Protocol Aux Number Aux On Function Aux Off Function Go to a preset36x optical zoom module MIC412TI and TF Dual Optical/Thermal PTZ CameraConnectivity MIC 412 models Upright 90 Dimension Drawings Appendix a Sonyset Camera CommandsDimension Drawings Pelco Appendix B Protocol Preset CodesWashwipeonpreset Washwipeoffpreset Vision Special Setup PresetsAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Europe, Middle East, Africa Contact AmericasAsia-Pacific Bosch Security Systems IncBosch Security Systems, Inc