Bosch Appliances MIC412 operation manual Table K Sonyset Commands Value

Page 46

MIC412TI and MIC412TF Camera Installation and Operation Manual

If only a few commands are utilised on the list then the rest should be set to "End" which will display "N/A" in the option column.

Below is a list of the available SonySet Commands and their corresponding Values or valid value ranges:

Table K – Sonyset Commands

Command

 

Value

EN 46

Iris Set

 

0 to 19

 

 

 

Gain Control

 

Reset / Plus 1 / Minus 1

 

 

 

Gain Set

 

0 to 19

 

 

 

Bright Control

 

Reset / Plus 1 / Minus 1

 

 

 

Bright Set

 

0 to 19

 

 

 

Exposure Comp Control

 

Reset / Plus 1 / Minus 1

 

 

 

Exposure Comp Set

 

0 to 14

 

 

 

Exposure Comp Mode

 

On / Off

Camera Power

Zoom Set

Digital Zoom

Focus Set

Focus Mode

Focus Control

AF Sensitivity

Focus Near Limit

White Balance Mode

On / Off

0 to 28672

On / Off

4096 to 49152

Auto / Manual

One Push Trigger / Force Infinity

High / Low 4096 to 49152

Auto / Indoor / Outdoor / One Push / Auto Tracing / Manual

Backlight

 

On / Off

 

 

 

Aperture Control

 

Reset / Plus 1 / Minus 1

 

 

 

Aperture Set

 

0 to 19

 

 

 

Low Lux

 

On / Off

 

 

 

Hi Resolution

 

On / Off

 

 

 

Image Flip Horiz

 

On / Off

 

 

 

Freeze Frame

 

Off / Negative / Black & White

 

 

 

On Screen Data

 

On / Off

 

 

 

Caption Display

 

On / Off

White Balance Control

Red Gain Control

Red Gain Set

Blue Gain Control

Blue Gain Set

Exposure Mode

Slow Shutter Mode

Shutter Control

Shutter Set

Iris Control

One Push Trigger

Reset / Plus 1 / Minus 1

0 to 255

Reset / Plus 1 / Minus 1 0 to 255

Auto / Manual / Shutter Priority / Iris Priority / Gain Priority / Bright / Shutter Auto / Iris Auto / Gain Auto

Auto / Manual

Reset / Plus 1 / Minus 1

0 to 19

Reset / Plus 1 / Minus 1

Auto IR

 

On / Off

 

 

 

Camera Initialise

 

Lens Recal / Bad Pixel Correction

 

 

 

Image Flip

 

On / Off

 

 

 

End

 

N/A

 

 

 

Invalid

 

N/A

Bosch Security Systems

Issue 8

Image 46
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsMIC 412 Options FeaturesPackaging Contents WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsLightning Protection Earthing of the MIC 412 cameraElectrical Connections MIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL MIC 412TI and MIC 412TF Power Supply UnitsPower Supply Layout and Connections PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Rating for 240v Primary Terminal Box ConnectorTerminal Box ID Marking Fuse Fuse function Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Table G Connecting the Greenwich Adaptor Connecting the MIC 412 to the PCConnecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorConnecting the MIC-USB485CVTR, USB to RS485 Converter Table I Camera Interface Control Settings DIP SwitchCamset Tabs Wire RS485 Wire RS422 MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Commissioning the MIC412 through Universal Camset Boot MessagesMIC Settings Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Focus Controls Preset PositionsIris Controls AuxiliariesTour Controls Preset ToursPattern Tours Non-Dwell Zone MIC SetupsSoft Stops and Non Dwell Zones ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Frame Integration Settings Multi Alarm SettingsLearn Alarm Positions Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions Shutter Open/Close FFC Mode and SettingsThermal Gain and Auto Gain ModesTimers Advanced SettingsTemperature and Humidity Clear All StatisticsDownload Eeprom To File Eeprom CopierOnly Upload Eeprom From FileMenu Controls Panasonic Only Manual and Preset / Goto ControlsPOT Test Matrix ControlsPot Test Controls Visible TracesPot Test Results CommsMouse Point Values Send Direct Command MIC Comms Communications TestingAlarms Cam CommsSony Set Get Preset from MICSend Preset to MIC SonySet ControlsSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity Dimension Drawings Appendix a Sonyset Camera CommandsMIC 412 models Upright 90 Dimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncBosch Security Systems, Inc