Bosch Appliances MIC412 operation manual Auto Home Controls, Other controls

Page 30

MIC412TI and MIC412TF Camera Installation and Operation Manual

Auto Flip

With this enabled the MIC will pan through 180 degrees as it reaches the vertical position so the user can then tilt down the other side meaning the MIC video is never inverted. Once the rotation is complete the controls are reversed until a stop command is received, at which point they are returned to normal.

Auto IR

In this mode the camera module is monitored for its current IR state, as soon as the light drops sufficiently, the module will automatically put the cut filter in place and switch to black and white, at which point the MIC will turn on the IR lamps.

Auto Lowlight

If this is turned on, the MIC will decrease its shutter speed as the light levels drop, rather than increasing the gain. Motion blur on the video can occur if the frame rate drops sufficiently low, which may not be ideal for a camera which is continually moving. However if motionless, the images will not have the grain associated with lowlight conditions. The gain at which a change is made and the lowest frame rate can be controlled under the Frame Integration section.

Auto Home Controls

After a programmable time with no manual control the MIC can be configured to either, move to the home position (Preset 1) or start tour / pattern 1. With Auto Home turned off the MIC will simply remain stationary until the next user input. The amount of time before this takes place can be set using the input boxes and the Set Time button.

EN 30

Other controls

Learn Wash Position

This is the position that the MIC will return to when the Washer Auxiliary is activated and Wash Wipe is turned on. This should point towards the washer jet nozzle.

Learn Alarm Position

This is the alarm position for the tamper switch. The MIC will return to this position if Auto Alarm is turned on, Multi Alarm is turned off and the tamper line in the PSU is pulled to ground.

Find End Stops

This will get the MIC to rotate in the tilt axis first down then up to its mechanical limit stops. It will then store a "soft" limit a few units back from these for normal use. During this process manual control is not available.

Show Boot Message

This will display the boot message that appears on the video for a few seconds, this may be helpful to determine the current software of the MIC, without having to do a full reboot.

Bosch Security Systems

Issue 8

Image 30
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsMIC 412 Options FeaturesPackaging Contents WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsEarthing of the MIC 412 camera Lightning ProtectionElectrical Connections MIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL MIC 412TI and MIC 412TF Power Supply UnitsPower Supply Layout and Connections PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Rating for 240v Primary Terminal Box ConnectorTerminal Box ID Marking Fuse Fuse function Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Table G Connecting the Greenwich Adaptor Connecting the MIC 412 to the PCConnecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorTable I Camera Interface Control Settings DIP Switch Connecting the MIC-USB485CVTR, USB to RS485 ConverterCamset Tabs Wire RS485 Wire RS422 MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Commissioning the MIC412 through Universal Camset Boot MessagesMIC Settings Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Focus Controls Preset PositionsIris Controls AuxiliariesPreset Tours Tour ControlsPattern Tours Non-Dwell Zone MIC SetupsSoft Stops and Non Dwell Zones ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Frame Integration Settings Multi Alarm SettingsLearn Alarm Positions Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions Shutter Open/Close FFC Mode and SettingsThermal Gain and Auto Gain ModesTimers Advanced SettingsTemperature and Humidity Clear All StatisticsDownload Eeprom To File Eeprom CopierOnly Upload Eeprom From FileMenu Controls Panasonic Only Manual and Preset / Goto ControlsPOT Test Matrix ControlsPot Test Controls Visible TracesComms Pot Test ResultsMouse Point Values Send Direct Command MIC Comms Communications TestingAlarms Cam CommsSony Set Get Preset from MICSend Preset to MIC SonySet ControlsSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity Appendix a Sonyset Camera Commands Dimension DrawingsMIC 412 models Upright 90 Dimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncBosch Security Systems, Inc