JVC GY-DV5000 manual Troubleshooting, Symptoms Remedy, Type

Page 93

13. OTHERS

13-2 Troubleshooting

Symptoms

Remedy

 

 

Power cannot be switched ON.

Is power supply connected correctly?

 

Is battery pack recharged?

 

Was the power turned ON immediately after being turned OFF?

 

Wait at least 5 seconds before turning the power ON again once it has been

 

turned OFF.

 

 

Recording is not possible.

Is the switch on cassette set to “REC”? If it is set to “SAVE”, set it to “REC”.

 

The Camera mode has not been selected. (The CAM indicator does not light.)

 

While the VTR indicator lights, press the MODE switch upward to turn on the

 

CAM indicator.

 

 

Camera image does not appear on LCD

The Camera mode has not been selected. (The CAM indicator does not light.)

monitor or in viewfinder.

While the VTR indicator lights, camera image will not be output. Press the

 

MODE switch upward to turn on the CAM indicator.

 

 

Image shown on LCD monitor or in

Adjust the brightness of the LCD monitor or viewfinder screen.

viewfinder is dark or blurred.

Is the colour temperature conversion filter knob set to 5600K+ND?

 

Is the iris closed?

 

Is the shutter speed too fast?

 

Is the viewfinder cable correctly connected?

 

 

Playback does not start when the play

In the Camera mode, is “STOP” indicated as the VTR operation mode indicator?

button is pressed.

When “STBY” is indicated, press the STOP button to display “STOP”.

 

 

DV signal cannot be input.

The VTR mode has not been selected. (The VTR indicator does not light.)

(GY-DV5001 only)

 

 

 

Noise interferes with playback video.

Video head may be clogged with dirt. Clean head with the special head cleaning

 

tape. (See “Precautions for Use of Head Cleaning Tape” on page 7.)

 

 

Sound is not output during playback.

Is the AUDIO SELECT item on the AUDIO menu screen set to CH3/4.

 

To output the sound of the recording, set to CH1/2.

 

 

Noise appears when playing back a tape

When a tape recorded on another unit is played back or used for recording, this

recorded on another unit.

phenomenon may occur due to tracking errors.

 

 

The transient section between scenes

 

recorded on other units and those

 

recorded on the GY-DV5000 may appear

 

disturbed.

 

 

 

The front section’s audio level control

Is the CH1 FRONT VR item on the AUDIO menu screen set to “DISABLE”? If

doesn’t work.

so, set to “ENABLE”.

 

 

The front section’s audio level control

The front section’s audio level control cannot be used to change the audio level

doesn’t change the audio level of the

of the sound input to CH2. Use the side section’s CH2 audio level control for this

sound input to CH2.

purpose.

 

 

Remaining battery power display is

The OTHERS (2/2) menu screen’s BATTERY TYPE item may not be set

incorrect.

correctly in accordance with the type of battery in use. If the menu item setting is

 

incorrect, set it correctly using the OTHERS (2/2) menu screen’s item BATTERY

 

Battery alarm is displayed and the GY-

TYPE.

DV5000 enters the non-operating mode

Is the battery old?

even when a fully charged battery is

 

used.

 

 

 

Cassette cannot be ejected after the

The capacity of the power supply may be insufficient. Check the power voltage.

power is turned ON.

 

 

 

Time code or user’s bits data not

Is the TC/UB item on the LCD/VF menu screen set to OFF? If so, set to ON.

displayed.

 

 

 

The date and time are not displayed or

Is the DISPLAY item on the TIME/DATE menu screen set to OFF? Set to ON

recorded.

when the data should be displayed and recorded.

 

To record the data, set the DATE REC item as well.

 

Is the date and time setting made?

 

See “Setting, Displaying and Recording the Date and Time” on page 41-43.

 

 

E-93

Image 93
Contents LWT0074-001C-H GY-DV5001MANUEL D’INSTRUCTIONS Instrucciones IstruzioniDV signal input is possible with the GY-DV5001E Port Cable LengthThese instructions are for the GY-DV5000E and GY-DV5001E Rating plate serial number plate is on the top frame Main Features Connecting a Video Component with DV Connector Main FeaturesAC Operation Battery Pack Operation Optional 11-11Introduction Precautions for Proper UsePrecautions for Use of Head Cleaning Tape Routine and Periodical MaintenanceHead cleaner Tape guides & rollers Time managementUse JVC’s videocassette tapes marked with the or Symbol Battery Pack to be UsedVideocassette to be Used For recording and storing videotapes in the best conditionCondensation Characteristic CCD PhenomenaSmear and Blooming Moire or AliasingFront Section CONTROLS, Indicators and ConnectorsFilter Colour temperature conversion filter control knob Auto WHITE/ACCU Focus switchLens mounting ring/Lens lock lever White BalanceRight Side Section CAM Camera mode indicator Black Black stretch/black compression switchVTR VTR mode indicator Power Power ON/OFF switchRight Side Section Cont’d @ Monitor Select Audio monitor selector switch CH-1/CH-2 Audio Input CH-1/CH-2 audio input selector switch# Counter Counter display switch $ TC GENE. Time code generator setting switchCH1/CH2 Line OUT CH1/CH2 line output connector RCA Monitor OUT Monitor output connector BNCC OUT Y/C output connector 4-pin Left Side SectionTop Section Rear Section Battery holder DV connectorBattery holder lock release knob Breaker Breaker buttonVTR mode Example of display Camera mode Example of displayIndications on the LCD Monitor and in the Viewfinder Status ScreensStatus Screens in the Camera Mode Indications on the LCD Monitor and in the Viewfinder Cont’d Status Screen in VTR Mode Magnified Status Indications on the LCD Monitor Head Cleaning Required Cleaning TapeNtsc Inhibit REC InhibitSafety Zone Indication Camera mode only Auto White Balance Indication Camera mode onlyMenu Setting Screen TOP Menu screen Camera modeS14 x 7.3B12U Zoom Lens OptionalVF-P115B 1.5-Inch Viewfinder OptionalBasic System Basic System Connections and AdjustmentsAttaching the Viewfinder Attaching the Zoom LensPin Hole ViewfinderAttaching the Microphone Using KA-A50U Attaching the Microphone ProvidedAttaching the Microphone Optional Attaching the Tripod Base Provided Front mount clip Safety lever Lock leverTripod mounting holes Front base mountBattery Pack Operation Optional Power SupplyFlat shape type battery pack Anton-Bauer battery pack AC OperationUsing a Flat Shape Type Battery Pack optional Battery Pack Operation Optional Cont’dUsing an Anton-Bauer Battery Pack Attaching the Battery PackDetaching the Battery Pack Battery Pack Continuous Operating Time at 25 ˚C Operating Time with Battery PackRecharging SonyTurning the Power OFF Turning the Power onMode Operation PreparationsLoading the Cassette Cassette Loading and UnloadingREC Save VTRUnloading the Cassette Open knobCassette cover Eject button Viewing the LCD Monitor Adjusting the LCD monitorOpening the LCD monitor Changing the orientation and angle of the LCD monitorSetting the Date and Time Setting, Displaying and Recording the Date and TimeDial MenuClock Adjust menu screen Date Year/Month/Day Setting, Displaying and Recording the Date and Time Cont’dRecording the Date and Time Data Displaying the Time and Date on the ScreenCharging the Built-in Battery How to chargeAC outlet AA-P250 DC cable Screen Size 43/LETTER Mode Selection Camera SettingsFilter Suitable LocationExternal Monitor Adjustment Viewfinder AdjustmentAdjust the position and angle of the viewfinder Colour video monitorAccu Focus can also be used in the above step Back Focus AdjustmentWhite Balance Adjustment Audio Input Signal Selection LineMIC Recording Level Adjustment Auto mode is selected in the Full Auto shooting modeUsing the audio input level control on the front section Monitoring Audio during Recording Monitor Select switchBasic Recording Operation Shooting OperationWhen the power should be turned off When it is required to unload the videocassetteAbout the Quick REC Start Mode Tally lampEdit Search Searching for Recorded Scenes Edit SearchScreen indications during Edit Search Searching the tape in forward directionSetting the time before the tape protection mode is Engaged If the Record-Standby Mode ContinuesHeader REC menu screen contents Header REC FunctionDescription How to set the Header REC menu screen Executing the Header REC FunctionDuring Header REC Output switch Colour bar signal of the built-in signal generatorRecording the Colour Bars Playback Procedure Playback ModePower switch Mode switch Display of time codeFast-Forward, Rewind SearchBlank Search VTR indicator SettingOutputting CH-3, CH-4 Channel Audio Shutter dial Status button TOP Menu screenUsing External Components Connecting a Video Component with DV ConnectorDV connector DV cable VC-VDV204 4P-4P, VC-VDV206 4P- 6P Operation Connections SettingsDate and time data Data transmitted from the playback unit is recordedTC GENE. switch Presetting and Recording of Time CodeTime Code Operation Displaying Time CodeTime code hour, min, sec, frame Zero-resetting the Time Code or User’s Bit DataTC Gene switch Set the TC Gene switch inside the cover on the side toReproducing Time Codes RegenMenu Screens 11-1Menu Screen ConfigurationStatus button 11-2Setting Menu ScreensShutter STA Termenu dial Cursor Menu screenReading Out a Menu Settings File Storing Setting ValuesResetting the Menu Settings to the Factory Settings 11-3FILE Manage Menu Screen11-4TOP Menu Screen 11-5CAMERA Operation Menu Screen 11-6CAMERA Process Menu Screen 11-7ADVANCED Process Screen 11-8SKIN Color Adjust Screen11-9AUDIO Menu Screen 11-10 LCD/VF Menu Screen 11-10 LCD/VF Menu Screen Cont’d 11-11 TC/UB/CLOCK Menu Screen Header REC Menu Screen TIME/DATE Menu Screen Others Menu Screen Battery Alarm VRType FrontSetting procedure Features of the Camera SectionWHT.BAL switch Full-Time Auto White Balance FAWAutomatic adjustment Iris Brightness AdjustmentManual adjustment Temporary auto iris adjustmentOperation Adjusting the Shutter SpeedShutter STA TER Set the Shutter item on the Camera Operation menu screen Variable Scan V.SCAN Shooting the Screen Image on a Computer MonitorBand Video monitor Basic operationGain switch Gain Sensitivity AdjustmentSwitch Position Factory-Set Gain Relationship between gain, iris and shutterAutomatic Setting Contents Switch Setup According to Illumination and SubjectSetting the Color and Range of the Skin Detail Function How to Use Skin DetailDetection AreaUsing the Skin Detail Function StatusDisplay Others Alarm Indications and Actions Screen indications on the LCD monitor and in the Viewfinder Indication Condition RemedyError Code Error Details GY-DV5000 Operation Remedy Blinking Pattern Remaining Battery/TapeTally lamp Camera to operate REC/ALARM lamp Battery lamp Alarm Indications and Actions Cont’dAlarm Sound Viewfinder Warning LampsSymptoms Remedy TroubleshootingTape. See Precautions for Use of Head Cleaning Tape on TypeShutter dial Status button Hour Meter DisplayOthers 2/2 menu screen Accumulated drum running timeSpecifications External Dimensions unit mm Specifications Cont’dViewfinder VF-P115B, VF-P116 Power zoom lens YH16 ⋅ 7K12U, YH19 ⋅ 6.7K12U CanonGY-DV5000/GY-DV5001 DV Camcorder
Related manuals
Manual 49 pages 20.81 Kb