To reset to the factory settings (CAMERA RESET)
1.Move the cursor to CAMERA RESET. PUSH SW is highlighted.
2.While holding down L and M, hold down I for 2 seconds or more. The camera is reset to the factory settings.
NETWORK SET UP
Set up network parameters when connecting the 10/100BASE jack with a network.
Notes:
•Access the setup menu from the PC to use the DHCP or DNS server, because these settings are not included in this window.
•Ask your system administrator or ISP (Internet Service Provider) about available IP address, sub- net mask, and gateway, prior to setup.
•The assigned address should be a global type when connecting via the Internet. Ask your ISP whether it is.
** NETWORK SET UP **
IP ADDRESS
192.168. 0. 10
NETMASK
255.255.255. 0
GATEWAY
192.168. 0. 1
HTTP PORT NO. 80
RET END
1.Move the cursor to NETWORK SET UP in the SET UP menu window and press I. The NETWORK SET UP menu opens.
The factory default settings are as follows. IP ADDRESS: 192.168.0.10 NETMASK: 255.255.255.0 GATEWAY: 192.168.0.1
HTTP Port Number: 80
2.Move the cursor to the line you wish to edit, and press I.
Parameters become editable.
3.Select a digit using J or K.
4.Select a number in the digit using L or M.
5.Repeat steps 2, 3 and 4 above appropriately until all parameters are set.
6.Move the cursor to END and press I to close the setup menu and store new settings, or select RET to go back to the SET UP menu.
Note: The port number assigned to the camera is exclusive, and any other usage is not allowed.