Connection type 2

IP address

Set the IP address designated by your network administrator.

 

 

However, the setting is not required if DHCP is used in an

 

 

intranet.

 

 

 

 

Subnet mask

Set the subnet mask designated by your network administra-

 

 

tor.

 

 

However, the setting is not required if DHCP is used in an

 

 

intranet.

 

 

 

 

Default gateway

Set the IP address of the default gateway designated by your

 

 

network administrator.

 

 

However, the setting is not required if DHCP is used in an

 

 

intranet.

 

 

 

 

Network speed

Set the network speed.

 

 

Use the default setting “auto” for the network speed.

 

 

Selectable parameters: auto (default setting), 100 Mbps (full

 

 

duplex), 100 Mbps (half duplex), 10 Mbps (full duplex), 10

 

 

Mbps (half duplex)

 

 

 

 

HTTP port

Use the default setting “80” for the HTTP port.

 

 

 

 

Host name

Refer to your network administrator and set the designated

 

 

host name if required.

 

 

 

 

DNS

Set to ON when using the DNS server.

 

 

 

 

Primary server

No setting required

 

 

 

 

Secondary server

Set the IP address of DNS when using the DNS server.

 

 

Refer to your Internet service provider for the IP address of

 

 

DNS. Primary and secondary IP addresses can be set for the

 

 

DNS.

 

 

 

 

DHCP

Set to ON if the intranet uses DHCP.

 

 

 

Connection type 3

IP address

Set the IP address designated by your Internet service

 

 

provider.

 

 

However, the setting is not required if your Internet service

 

 

provider uses a DHCP server (the DHCP server assigns an

 

 

IP address to the camera automatically).

 

 

 

 

Subnet mask

Set the subnet mask designated by your Internet service

 

 

provider.

 

 

However, the setting is not required if your Internet service

 

 

provider uses a DHCP server (the DHCP server assigns an

 

 

IP address to the camera automatically).

 

 

 

 

Default gateway

Set the default gateway designated by your Internet service

 

 

provider.

 

 

 

 

Network speed

Set the network speed.

 

 

Use the default setting “auto” for the network speed.

 

 

Selectable parameters: auto (default setting), 100 Mbps (full

 

 

duplex), 100 Mbps (half duplex), 10 Mbps (full duplex), 10

 

 

Mbps (half duplex)

 

 

 

 

HTTP port

Use the default setting “80” for the HTTP port.

 

 

 

 

Host name

Refer to your Internet service provider and set the designated

 

 

host name if required.

 

 

 

 

DNS

Set to ON when using the DNS server.

 

 

 

 

Primary server

No setting required

 

 

 

-26-

Image 26
Contents Operating Instructions Risk of Electric Shock Do not Open Contents Preface TCP/IP, HTTP, FTP, SMTP, DNS, DhcpHandle the camera with care PrecautionsClean the CCD faceplate with care Never face the camera toward the sunMajor Operating Controls and Their Functions Mounting the Lens Notes InstallationsReplacement of Auto Iris Lens Connector Mounting from the Top Flange-back AdjustmentMounting from the Bottom Pictures Upside-downControl Terminal Connections Power-in ConnectionsConnections Video Cable ConnectionsConnection to Intranet Type Connection to Internet TypeOperating the Camera Access from the PCPreliminary Setup Function Comparison / PC Network vs. Camera site Access from the Camera/System DeviceNetwork Speed Select a speed Camera Setup Menus Prior to SET UPButtons Used for Setup Menus ¡From the PC¡From the Camera Setting Procedures Camera Identification Camera ID SettingLight Control Setting ALC/ELC ALC Mode with SUPER-D2 onALC Mode with SUPER-D2 OFF and ELC Mode Shutter Speed Setting ShutterGain Control Setting AGC on DNR-H, DNR-L/OFF Electronic Sensitivity Enhancement Sens UP White Balance Setting White BALAuto-Tracing White Balance Mode ATW ATW1 Auto-Tracing White BalanceDate Display Clock Setting Motion Detector Setting Motion DETLens Drive Signal Selection Lens Drive Manual Fine Adjustment for AWC ATWSpecial Menu To reset to the factory settings Camera Reset Http Port NumberConnection to Internet Type SET UP from the PCConnections Connection to Intranet TypeNetwork Setup of the PC Network Setup of the Camera DNS Network Setup Parameters vs. Connection TypeConnection type Description of the parameter DhcpSet to on when using the DNS server Set to on if your internet Internet service provider uses a Set to on if the router uses Dhcp Reset button ALL Reset Setup Menu buttonDay & Night Mode Setup buttons ON/OFF/AUTO Return buttonCamera Setup Menus Image Capture Size pixels 752x568*, 752x280, 368x280 PC Oriented SET UPAlarm Setup Image Setup FTP Client Setup User Setup Host Setup System SetupInitializing the Camera Menu Initializing the Setup MenuInitializing Initializing Html FilesImage Capture Size pixels 752x568 Viewing PicturesImage Quality Selection Monochrome Mode Transferring Picture Files Alarm FunctionsWhen an Alarm Arises Detection Area Setup Canceling Alarm DisplayVMD Setup EnterReviewing Alarm Pictures Resetting Alarm Auxiliary Output Control Auxiliary Output ControlTroubleshooting Network Section SpecificationsGeneral Camera SectionStandard Accessories Optional Accessories2003