Parts and their functions
9PRESET/LIMIT button
This is used to register the settings in the preset memories or set or release the limiters.
When a preset memory call button is pressed while the PRESET/LIMIT button is held down, the information on the unit’s current direction and other settings is registered in the call button.
Preset memory call buttons [1] to [12] correspond to the unit’s No.1 to No.12 preset memories.
Furthermore, the pan and tilt movement range limits (limiters) are set and released by operating the PRESET/ LIMIT button and the pan/tilt buttons ([], [], [] and []). For details, refer to “Setting/releasing the limiters” (page 54).
Pan-tilt buttons and menu operation buttons [] [] [] [] []
These are used to change the unit’s direction.
The unit is tilted in the up/down direction using the [] and [] buttons and panned in the left/right direction using the [] and [] buttons.
The [] button does not work during tilting and panning. When the [] or [] and [] or [] buttons are pressed at the same time, the unit moves diagonally.
The buttons are used for menu operations when the unit displays the menus.
The menu items are selected using the [] and [] buttons, and the values for the menu items are changed using the [] and [] buttons.
When a selected item has a
Bear in mind, however, that if the [] button is pressed when it is possible to change a value, the value will be changed by the button.
FOCUS buttons [F] [N]
These are used to adjust the lens focus manually when the manual setting is established for the lens focus.
The focus is adjusted in the far using the [F] button and in the near using the [N] button.
A/FOCUS button
This is used when automatically adjusting the lens focus.
M/FOCUS button
This is used when manually adjusting the lens focus. The FOCUS buttons ([F] and [N]) are used when performing the actual adjustment.
OPT buttons [ON] [OFF]
These are used for future expansion of the functions. They are not used at the present time.
HOME button
When this is pressed for two seconds, the unit’s direction (panning or tilting) returns to the reference position.
ZOOM buttons [T] [W]
These are used to adjust the lens zoom.
The zoom is adjusted in the
FAST button
This is used to change the movement speed at which the panning, tilting, zooming and focusing operations are performed to the high speed.
The same applies for the movement speeds of panning and tilting when the information in a preset memory has been called.
SLOW button
This is used to change the movement speed at which the panning, tilting, zooming and focusing operations are performed to the low speed.
The same applies for the movement speeds of panning and tilting when the information in a preset memory has been called.
A/IRIS button
This establishes the setting for adjusting the lens iris automatically in line with the light quantity.
M/IRIS button
This establishes the setting for adjusting the lens iris manually.
The IRIS+ and IRIS– buttons are used when performing the actual adjustment.
IRIS+ button
This is used to adjust the lens iris in the opening direction.
IRIS– button
This is used to adjust the lens iris in the closing direction.
Notes
The iris is automatically changed to the automatic adjustment if the gain is set to the automatic adjustment while the iris is at the manual adjustment setting.
If the gain is later returned to the manual adjustment setting, the iris is also returned to its original value.
The gain is automatically changed back to its previous value if the iris is set to the manual adjustment while the gain is at the automatic adjustment setting.