Security Escort Technical Reference Manual 3.0 System Menus | EN 45 | |
and Screens | ||
|
| Off |
| Status Screen |
|
| When clicked, the checked |
|
|
|
|
|
|
| |
| green LED and |
|
|
|
| are turned off for the selected point |
|
|
|
| on the selected transponder. If the |
|
|
|
| output does not change, click On Output |
|
|
|
| Command and click Off again. |
|
|
|
| On Output Command |
|
|
|
| When clicked, the checked |
|
|
|
| green LED, and |
|
|
|
| are turned on for the selected point on |
|
|
|
| the selected transponder. If the output |
|
|
|
| does not change, click Off and then |
|
|
|
| click On Output Command again. |
|
|
|
| Transponder |
|
|
|
| Selects the transponder you desire to |
|
|
|
|
| Transponder | ||
| communicate with. |
| ||
| Previous |
| Selects the transponder you want to see | |
| Returns to the previous transponder. |
| the status of. | |
|
| Total Alarms Received | ||
| Next |
| ||
|
| The total number of alarm messages | ||
| Advances to the next transponder. |
| ||
|
| received by the central console from | ||
| Bus X Point Y |
| ||
|
| this transponder since the data was | ||
| This field displays the current bus |
| last reset (using the Reset Transponder | |
|
| Troubles button). | ||
| number and point number. The actual |
| ||
|
|
|
| |
| point number may be entered in the |
| Total Tests Received | |
| field to the right. |
| The total number of test messages | |
? |
| |||
| received by the central console from | |||
| Opens up the Select Point Screen. |
| this transponder since the data was | |
|
| last reset (using the Reset Transponder | ||
+ |
| |||
| Troubles button). | |||
|
|
| ||
| Advances to the next point. |
| Total Troubles Processed | |
|
|
| ||
- |
| The total number of trouble messages | ||
|
|
| ||
| Returns to the previous point. |
| received by the central console from | |
| Unlimited Retries |
| the transponder and processed (see | |
|
| Total Troubles Shed) since the data was | ||
| When this box is checked, the central |
| ||
|
| last reset (using the Reset Transponder | ||
| console continues trying to send |
| Troubles button). | |
| commands to a transponder even if the |
| ||
|
| Total Troubles Shed | ||
| commands are not being acknowledged. |
| ||
|
|
|
| |
| (Normally, the central console would |
| During certain rare occurrences, the | |
| cease after six retries and declare a |
| communication traffic on the | |
| communication failure.) When this |
| transponder links becomes excessive and | |
| screen is closed, the system reverts to |
| threatens to increase the system | |
| the normal six retries. |
| response time to tests and alarms. This | |
| 3.3.10 Transponder Current Status |
| can happen if faults are reported at a | |
|
| very high rate. To avoid slow response | ||
| Screen |
| ||
|
| in such situations, the central console | ||
| This screen, accessible from the Main |
| ||
|
| may go into a load shedding mode in | ||
| Menu under the Setup selection, |
| which it ceases to record and display | |
| provides a history of communications |
| Trouble Reports until the | |
| involving the transponder selected in |
| communications traffic subsides. The | |
| the transponder box. It also provides |
| Total Troubles Shed box indicates the | |
| several buttons, that can be used to |
| number of trouble messages that were | |
| diagnose problems with the transponder |
| not processed since the last reset | |
| and any of its receivers or alert |
| (using Reset Transponder Troubles | |
| units. |
| button). | |
| Figure 433: Transponder Current |
|
|
|
|
|
|
|
|
Bosch Security Systems 6/12 38947D |
|
|
|