Security Escort Technical Reference Manual 3.0 System Menus
and Screens
EN 16
Enable Reed Switch
If checked, the reed switch input of this transmitter is enabled and causes an alarm. Otherwise, the reed switch input is disabled. The alarm group this transmitter is assigned to must be armed, for this input to cause an alarm, which is displayed. If no alarm group is assigned, the transmitter is always armed. To enable this option, the transmitter’s class must be set to point type.
Optional Text
This is optional text that can be added to the location text when this input reports an alarm. To enable this option, the transmitter’s class must be set to point type.
Disable Shorted Loop
If selected, a shorted loop on this transmitter does not cause an alarm or trouble report to display. To enable this option, the transmitter’s class must be set to point type.
Alarm on Shorted Loop
If selected and the alarm group this transmitter is assigned to is armed, a shorted loop on this transmitter causes an Alarm Report to display. For this input to cause an alarm, the alarm group this transmitter is assigned to must be armed, which is displayed. If no alarm group is assigned, the transmitter is always armed. To enable this option, the transmitter’s class must be set to point type.
Trouble on Shorted Loop
If selected, a shorted loop on this transmitter causes a Trouble Report to display. To enable this option, the transmitter’s class must be set to point type.
Alarm When Armed, Trouble When Disarmed on Shorted Loop
If selected and the alarm group this transmitter is assigned to is armed, a shorted loop on this transmitter causes an Alarm Report to display. If selected and the alarm group this transmitter is assigned to is disarmed, then a shorted loop on this transmitter causes a Trouble Report to display. If no alarm group is assigned, the transmitter is always armed. To enable this option, the transmitter’s class must be set to point type.
Disable Open Loop
If selected, an open loop on this transmitter does not cause an Alarm or Trouble Report to display. To enable this option, the transmitter’s class must be set to point type.
Alarm on Open Loop
If selected and the alarm group this transmitter is assigned to is armed, an open loop on this transmitter causes an Alarm Report to display. The alarm group this transmitter is assigned to must be armed for this input to cause an alarm, which is displayed. If no alarm group is assigned, the transmitter is always armed. To enable this option, the transmitter’s class must be set to point type.
Trouble on Open Loop
If selected, an open loop on this transmitter causes a Trouble Report to display. To enable this option, the transmitter’s class must be set to point type.
Alarm When Armed, Trouble When Disarmed on Open Loop
If selected and the alarm group this transmitter is assigned to is armed, an open loop on this transmitter causes an Alarm Report to display. If selected and the alarm group this transmitter is assigned to is disarmed, an open loop on this transmitter causes a Trouble Report to display. If no alarm group is assigned, the transmitter is always armed. To enable this option, the transmitter’s class must be set to point type.
Fixed Location and Pager Text
This is the text that displays as the location of the alarm for fixed location transmitters and on pagers reporting this alarm.
Transponder Name
Select the transponder with the area that defines the area for a wandering (virtual fence) alarm. Refer to Transponder Area for the operation and setup of the wandering alarm (virtual fence alarm).
Bosch Security Systems 6/12 38947D