Maximum Low Battery Messages
This value is the maximum number of transmitters with low batteries yet to be displayed. If displayed in yellow, more than 50% of the queue was in use.
Maximum Test Strobe Messages
This value is the maximum number of test strobes in use at one time. If displayed in yellow, more than 50% of the queue was in use.
Max Man Down Messages
This value is the maximum number of transmitters timing man down events, at one time. If displayed in yellow, more than 50% of the queue was in use.
Supervision Monitors
This value is the current number of transmitters being monitored for supervision transmissions.
Max Spooler Bytes
This value is the maximum number of bytes spooled for the printer at one time. If displayed in yellow, more than 50% of the queue was in use.
Max Report Spooler Bytes
This value is the maximum number of bytes spooled for the printer for Guard Tour Reports at one time. If displayed in yellow, more than 50% of the queue was in use.
Max Receiver Buffer
This value is the maximum number of bytes received from transponders on this serial port, but not yet processed by the system. If displayed in yellow, more than 50% of the queue was in use.
Max Transmit Buffer
This value is the maximum number of bytes processed by the system, but not yet transmitted to the transponders on this serial port. If displayed in yellow, more than 50% of the queue was in use.
Hardware Overrun
This is the number of times a byte was lost by the hardware for a serial port because it was not fast enough to process the byte into the input buffer.
Buffer Overflow Count
This is the number of times a byte was lost by the software for a serial port because the input buffer overflowed.
Bytes were placed into the input buffer faster than the system could process them.
Overload Level
This is a measure of the amount of time peak traffic on this serial port was greater than the system’s ability to handle it. The system automatically sheds
Overload Count
This is a measure of the number of times peak traffic on this serial port was greater than the system’s ability to handle it. The system automatically sheds
Reset Status
Pressing this button resets all values in this shown in this screen.
Refresh Data
Pressing this button refreshes all values shown in this screen. The values are not automatically updated when the screen is left open.
3.3.17 System Preferences Screen
The Set System Preferences Screen under the Setup Menu contains a number of settings that govern the behavior of the Security Escort System.
Figure 52: System Preferences Screen
Force Map Background Erase
Use this checkbox to erase the map screen. It should only be checked if there are problems with icons not being cleared properly from the screen; otherwise, it causes the screen to flicker.