■Connections
Cautions:
•This product should be installed and connected in conformity with local codes by qualified service personnel or system installers.
•See page 2 for mains lead connection.
•Do not use a transformer with a capacity of more than 20 V A.
•Use a class 2 power supply.
•To prevent fire or electric shock hazard, use a UL listed cable
•Be sure to connect the GND (grounding) lead of the camera and grounding terminal of the power supply.
Network
To network
Adapter (supplied)
Video output
BNC
BNC
To Video IN (CAMERA IN)
Control cable
Power 24 V AC
|
|
|
|
|
| To peripherals | ||
Adapter (supplied) |
|
|
| |||||
| Brown (Live) |
|
|
| ||||
|
|
|
| |||||
| Blue (Neutral) |
|
|
| ||||
| Green/Yellow (GND) |
|
|
| ||||
| ||||||||
| Black (Live) |
|
|
| For optional heater |
| ||
| Grey (Neutral) |
|
|
|
|
|
| |
|
|
|
|
|
Power 220 V - 240 V AC | Brown (Live) |
| Blue (Neutral) |
| Green/Yellow (GND) |
●Power Connection
Use individual power sources for the camera and optional heater unit.
• Wire colours & functions
24 V AC Type |
|
|
|
Wire colour |
| Function | Note |
|
|
|
|
Brown | 24 | V AC Live | For camera |
Blue | 24 | V AC Neutral | 8.6 W |
Green/Yellow | GND |
| |
Black | 24 | V AC Live | For optional heater |
Grey | 24 | V AC Neutral | 12.1 W |
220 V - 240 V AC Type |
| ||
Wire colour | Function | Note | |
|
|
| |
Brown | 220 V - 240 V AC | 9.9 W (camera) | |
Live | |||
|
| ||
|
|
| |
Blue | 220 V - 240 V AC | 18.9 W (with heater) | |
Neutral | |||
|
|
Green/Yellow GND
•Cable length and wire gauge 24 V AC Type
The recommended cable length and thickness are shown in the table for reference. The voltage sup- plied to the power terminals of the camera should be between 19.5 V AC and 28 V AC.
Copper wire size | #24 | #22 | #20 | #18 | ||
(AWG) |
| (0.22mm2) | (0.33mm2) | (0.52mm2) | (0.83mm2) | |
|
|
|
|
|
| |
Length | (m) | 20 | 30 | 45 | 75 | |
of cable |
|
|
|
|
| |
(ft) | 65 | 100 | 160 | 260 | ||
(approx.) | ||||||
|
|
|
|
|
|