Panasonic WV-NW474SE Connections, Power Connection, Wire colours & functions AC Type, V AC Type

Page 11

Connections

Cautions:

This product should be installed and connected in conformity with local codes by qualified service personnel or system installers.

See page 2 for mains lead connection.

Do not use a transformer with a capacity of more than 20 V A.

Use a class 2 power supply.

To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for 24 V AC connections.

Be sure to connect the GND (grounding) lead of the camera and grounding terminal of the power supply.

Network

To network

Adapter (supplied)

Video output

BNC

BNC

To Video IN (CAMERA IN)

Control cable

Power 24 V AC

 

 

 

 

 

 

To peripherals

Adapter (supplied)

 

 

 

 

Brown (Live)

 

 

 

 

 

 

 

 

Blue (Neutral)

 

 

 

 

Green/Yellow (GND)

 

 

WV-NW474SE

 

 

Black (Live)

 

 

 

For optional heater

 

 

Grey (Neutral)

 

 

 

 

 

 

 

 

 

 

 

Power 220 V - 240 V AC

Brown (Live)

 

Blue (Neutral)

 

Green/Yellow (GND)

WV-NW470S

Power Connection

Use individual power sources for the camera and optional heater unit.

• Wire colours & functions

24 V AC Type

 

 

 

Wire colour

 

Function

Note

 

 

 

 

Brown

24

V AC Live

For camera

Blue

24

V AC Neutral

8.6 W

Green/Yellow

GND

 

Black

24

V AC Live

For optional heater

Grey

24

V AC Neutral

12.1 W

220 V - 240 V AC Type

 

Wire colour

Function

Note

 

 

 

Brown

220 V - 240 V AC

9.9 W (camera)

Live

 

 

 

 

 

Blue

220 V - 240 V AC

18.9 W (with heater)

Neutral

 

 

Green/Yellow GND

Cable length and wire gauge 24 V AC Type

The recommended cable length and thickness are shown in the table for reference. The voltage sup- plied to the power terminals of the camera should be between 19.5 V AC and 28 V AC.

Copper wire size

#24

#22

#20

#18

(AWG)

 

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

 

 

 

 

 

 

Length

(m)

20

30

45

75

of cable

 

 

 

 

 

(ft)

65

100

160

260

(approx.)

 

 

 

 

 

 

-11-

Image 11
Contents WV-NW474SE Risk of Electric Shock Do not Open Contents Trademarks FeaturesPreface System RequirementsDocument Convention Do not aim the camera at the same object for a long time PrecautionsHandle the camera with care Never face the camera towards the sunMajor Operating Controls & Their Functions @2Video output connector 8DIP switch@3Control connector @4Power cableProcurement InstallationInstallation Plans & Preparations Installation spaceOptional Heater Unit Mounting the CameraConnections Power ConnectionWire colours & functions AC Type Cable length and wire gauge 24 V AC TypeNetwork Port Connection Image AdjustmentControl Connector Video Output ConnectionWaterproof Process Connection to Internet Type Network Connection TypesDirect Connection to PC Type Connection to Intranet TypePreparations for Network Connections Network Setup of Your PCUsing Panasonic IP Setup Software Network Setup of the CameraDdns Dhcp DNSPage ALL Reset button Prior to Camera SetupButtons Used for Setup Camera Setup Menus¡From the Camera Setup Menu Tree Camera Identification Camera ID Setting Setting ProceduresSetup Selection Camera Setup Menu CAMTo replace a specific character in the Camera ID Light Control Setting ALCCommand Usage To edit the Camera IDElectronic Sensitivity Enhancement Sens UP Gain Control Setting AGC on DNR-L, DNR-H/OFFShutter Speed Setting Shutter ATW1 Auto-Tracing White Balance Synchronization Setting SyncWhite Balance Setting White BAL Push SW Motion Detector Setting Motion DETAutomatic White Balance Control Mode AWC Manual Fine Adjustment for AWC ATWSpecial Menu Special Menu/DIP SW Selection10-6. BW To reset to the factory settings Camera ResetHttp Port Number Network Setup Network SetupInitializing Html Files Initializing the Setup MenuInitializing Initializing the Camera MenuTroubleshooting Network Section SpecificationsTCP/IP, HTTP, FTP, SMTP, DNS, DDNS, DHCP, ARP, BOOTP, NTP Prevention of Blooming and SmearWV-NW474SE Standard AccessoriesOptional Accessories GeneralOptional Heater Unit WV-CW3HE Appendix在日本印刷