Panasonic WV-NW470S, WV-NW474SE Initializing the Camera Menu, Initializing the Setup Menu

Page 30

INITIALIZING

You can reset the following data back to the factory default settings.

Camera Setup

Setup Menu (PC oriented) HTML files

Initializing the Camera Menu

Move the cursor to CAMERA RESET.

Hold down [Left], [Right], and [SET] buttons simulta- neously for 2 seconds on the camera, or click the All Reset button on your computer display.

Initializing the Setup Menu

In the power-on state, press the [Up] and [Down] buttons simultaneously while holding down the but- ton A.

Hold down the button A for 15 seconds. It will take about 10 seconds to complete the initializing. Be sure to continue supplying power to the camera while initializing.

Notes:

Clock calibration is required even after initializing the setup menu.

Try again if the previous initializing failed.

Initializing HTML Files

In the power-on state, press the side panel buttons, [Up] and [Down] simultaneously while holding down the button B.

Hold down the button B for 15 seconds. It will take about 10 seconds to complete the initializing. Be sure to continue supplying power to the camera while initializing.

Notes:

Never press both the buttons A and B at a time.

Try again if the previous initializing failed.

-30-

Image 30
Contents WV-NW474SE Risk of Electric Shock Do not Open Contents System Requirements FeaturesPreface TrademarksDocument Convention Never face the camera towards the sun PrecautionsHandle the camera with care Do not aim the camera at the same object for a long timeMajor Operating Controls & Their Functions @4Power cable 8DIP switch@3Control connector @2Video output connectorInstallation space InstallationInstallation Plans & Preparations ProcurementMounting the Camera Optional Heater UnitCable length and wire gauge 24 V AC Type Power ConnectionWire colours & functions AC Type ConnectionsVideo Output Connection Image AdjustmentControl Connector Network Port ConnectionWaterproof Process Connection to Intranet Type Network Connection TypesDirect Connection to PC Type Connection to Internet TypeNetwork Setup of Your PC Preparations for Network ConnectionsNetwork Setup of the Camera Using Panasonic IP Setup SoftwareDhcp DNS DdnsPage Camera Setup Menus Prior to Camera SetupButtons Used for Setup ALL Reset button¡From the Camera Setup Menu Tree Camera Setup Menu CAM Setting ProceduresSetup Selection Camera Identification Camera ID SettingTo edit the Camera ID Light Control Setting ALCCommand Usage To replace a specific character in the Camera IDGain Control Setting AGC on DNR-L, DNR-H/OFF Shutter Speed Setting ShutterElectronic Sensitivity Enhancement Sens UP Synchronization Setting Sync White Balance Setting White BALATW1 Auto-Tracing White Balance Manual Fine Adjustment for AWC ATW Motion Detector Setting Motion DETAutomatic White Balance Control Mode AWC Push SWMenu/DIP SW Selection Special Menu SpecialTo reset to the factory settings Camera Reset 10-6. BWNetwork Setup Network Setup Http Port NumberInitializing the Camera Menu Initializing the Setup MenuInitializing Initializing Html FilesTroubleshooting Prevention of Blooming and Smear SpecificationsTCP/IP, HTTP, FTP, SMTP, DNS, DDNS, DHCP, ARP, BOOTP, NTP Network SectionGeneral Standard AccessoriesOptional Accessories WV-NW474SEAppendix Optional Heater Unit WV-CW3HE在日本印刷