Panasonic WV-NW470S, WV-NW474SE operating instructions Appendix, Optional Heater Unit WV-CW3HE

Page 34

APPENDIX

Optional Heater Unit WV-CW3HE

Introduction

Installing this heater unit enables the camera to operate under in a low-temperature environment of –30 °C (–22 °F). The heater turns on automatically when the temperature inside the camera drops below +10 °C (50 °F) and turns off when it rises.

A small fan inside the unit will minimize condensation on the surface of the dome cover caused by changes in ambi- ent temperature unless temperatures change too rapidly. The fan will stop when there is no possibility of condensa- tion.

Precautions

This product should be installed and connected by qualified service personnel or system installers.

Do not use the same 24 V AC power source supplying the power to the camera for the heater unit. Connect anoth- er 24 V AC power source to the heater unit. If the same power source is used, turning the heater on and off may disturb the camera images.

When servicing, pay attention to high temperature on the surface of the unit. Disconnect the harness and wait until it cools.

When you install the camera in a low-temperature location and start operating it, it may take time (around 30 min- utes) for the inside of the camera to warm up. Cut power once then supply power again.

Installation

1.

Open the dome cover. (See Disassembling the camera.)

2.

Place the heater unit in the camera and fix it with the sup-

Adhesive tape

 

plied screw.

3.

Insert the harness into the heater unit connector of the

 

camera.

4.

Fold the desiccant pack in half, and attach it with adhe-

 

sive tape to point "A" shown in the figure.

 

Note: Attach the desiccant pack so that it does not block

 

ventilation holes or hang over the top of the wall.

5.

Attach the dome cover while paying attention not to pinch

 

the harness cable.

Fold

Supplied screw

Harness

6. Connect the heater power cable of the camera. (See

Connection.)

Point "A" (wall)

Specifications

Required power:

24 V AC, 50

Hz

Power consumption:

12.1

W maximum

Dimensions:

29 mm (H) x 83 mm (W) x 89.5 mm (D)

 

[1-1/8" (H) x

3-1/4" (W) x 3-1/2" (D)]

Weights:

45 g

(0.1 lbs)

Accessories

Fixing screw (M3 x 12)

1 pc.

Desiccant pack

1 pc.

-34-

Image 34
Contents WV-NW474SE Risk of Electric Shock Do not Open Contents System Requirements FeaturesPreface TrademarksDocument Convention Never face the camera towards the sun PrecautionsHandle the camera with care Do not aim the camera at the same object for a long timeMajor Operating Controls & Their Functions @4Power cable 8DIP switch@3Control connector @2Video output connectorInstallation space InstallationInstallation Plans & Preparations ProcurementMounting the Camera Optional Heater UnitCable length and wire gauge 24 V AC Type Power ConnectionWire colours & functions AC Type ConnectionsVideo Output Connection Image AdjustmentControl Connector Network Port ConnectionWaterproof Process Connection to Intranet Type Network Connection TypesDirect Connection to PC Type Connection to Internet TypeNetwork Setup of Your PC Preparations for Network ConnectionsNetwork Setup of the Camera Using Panasonic IP Setup SoftwareDhcp DNS DdnsPage Camera Setup Menus Prior to Camera SetupButtons Used for Setup ALL Reset button¡From the Camera Setup Menu Tree Camera Setup Menu CAM Setting ProceduresSetup Selection Camera Identification Camera ID SettingTo edit the Camera ID Light Control Setting ALCCommand Usage To replace a specific character in the Camera IDShutter Speed Setting Shutter Gain Control Setting AGC on DNR-L, DNR-H/OFFElectronic Sensitivity Enhancement Sens UP White Balance Setting White BAL Synchronization Setting SyncATW1 Auto-Tracing White Balance Manual Fine Adjustment for AWC ATW Motion Detector Setting Motion DETAutomatic White Balance Control Mode AWC Push SWMenu/DIP SW Selection Special Menu SpecialTo reset to the factory settings Camera Reset 10-6. BWNetwork Setup Network Setup Http Port NumberInitializing the Camera Menu Initializing the Setup MenuInitializing Initializing Html FilesTroubleshooting Prevention of Blooming and Smear SpecificationsTCP/IP, HTTP, FTP, SMTP, DNS, DDNS, DHCP, ARP, BOOTP, NTP Network SectionGeneral Standard AccessoriesOptional Accessories WV-NW474SEAppendix Optional Heater Unit WV-CW3HE在日本印刷