Panasonic WV-NW470S, WV-NW474SE Setting Procedures, Setup Selection, Camera Setup Menu CAM

Page 22

SETTING PROCEDURES

The following pages describe setting operations from the camera.

For accessing from the PC, interpret these instructions as follows.

Function

From the Camera

From the PC

Opening the camera setup menu

Hold down the [SET] button for 2 seconds.

Click the Camera Setup button in the

 

 

main page to display the menu control

 

 

buttons.

 

 

Click the [MENU ON] button.

Closing the camera setup menu

Press the [SET] button while the cursor is

Click the [MENU OFF] button.

 

at END.

 

 

 

 

Opening a more detailed setup

Press the [SET] button while the cursor is

Click the [SET] button while the cursor is

menu

at an item tailed with O mark.

at the item tailed with O mark.

Returning to the previous menu

Press the [SET] button while the cursor is

Click the [SET] button while the cursor is

 

at RET.

at RET or simply clock the [ESC] button.

 

 

 

Opening the special menu

Hold down the [Left] and [Right] buttons

Click the [RESET/SPECIAL] button while

 

simultaneously while the cursor is at END

the cursor is at END in CAM SETUP.

 

in CAM SETUP.

 

Resetting the parameter of an item

Hold down the [Left] and [Right] buttons

Click the [RESET/SPECIAL] button while

 

simultaneously while the cursor is at the

the cursor is at the item.

 

item.

 

Resetting all the settings

Hold down the [Left], [Right], and [SET]

Click the [ALL RESET] button while the

 

buttons simultaneously while the cursor is

cursor is at CAMERA RESET.

 

at CAMERA RESET.

 

Selecting an item

Press the [Up] or [Down] button.

Click the [D] or [C] button.

Selecting a parameter

Press the [Left] and [Right] button.

Click the [A] or [B] button.

Validating the selection

Press the [SET] button.

Click the [SET] button.

 

 

 

Escaping from the VMD mask setup

Hold down the [SET] button for 2 seconds.

Click the [ESC] button.

etc.

 

 

Setup Selection

**SET UP **

CAMERA

NETWORK

 

END

SET UP DISABLE

1.

Move the cursor to CAMERA or NETWORK, and

 

press [SET] to open the desired setup menu.

 

CAMERAN: Opens the CAMERA SETUP menu.

 

NETWORKN: Opens the NETWORK SETUP menu.

2.

Move the cursor to END, and press [SET] to return

 

to camera image screen.

Camera Setup Menu (CAM

SETUP)

** CAM SET UP **

CAMERA ID

OFF

 

ALC

ALC

SHUTTER

---

 

 

AGC

ON(DNR-H)

SENS UP

OFF

 

 

SYNC

INT

 

 

WHITE BAL

ATW1

MOTION DET

OFF

 

 

MENU

RET END

1. Camera Identification (CAMERA ID) Setting

You can assign a name to the camera. The camera ID consists of up to 16 alphanumeric characters. The camera ID display can be switched on and off on the monitor screen.

Note: When SETUP DISABLE appears in the bot-

tom line you cannot change the currently active

settings. This disablement is designed to pre- vent accidental setting change. Refer to the pre- vious page to change it to ENABLE.

Character Cursor

0123456789 ABCDEFGHIJKLM NOPQRSTUVWXYZ ().,'":;&#!?= +-*/%$ÄÜÖÆÑÅ

SPACE

POSI RET END RESET

................

Cursor

Character

Area

Command

Editing

Area

CAMERA ID menu

-22-

Image 22
Contents WV-NW474SE Risk of Electric Shock Do not Open Contents System Requirements FeaturesPreface TrademarksDocument Convention Never face the camera towards the sun PrecautionsHandle the camera with care Do not aim the camera at the same object for a long timeMajor Operating Controls & Their Functions @4Power cable 8DIP switch@3Control connector @2Video output connectorInstallation space InstallationInstallation Plans & Preparations ProcurementMounting the Camera Optional Heater UnitCable length and wire gauge 24 V AC Type Power ConnectionWire colours & functions AC Type ConnectionsVideo Output Connection Image AdjustmentControl Connector Network Port ConnectionWaterproof Process Connection to Intranet Type Network Connection TypesDirect Connection to PC Type Connection to Internet TypeNetwork Setup of Your PC Preparations for Network ConnectionsNetwork Setup of the Camera Using Panasonic IP Setup SoftwareDhcp DNS DdnsPage Camera Setup Menus Prior to Camera SetupButtons Used for Setup ALL Reset button¡From the Camera Setup Menu Tree Camera Setup Menu CAM Setting ProceduresSetup Selection Camera Identification Camera ID SettingTo edit the Camera ID Light Control Setting ALCCommand Usage To replace a specific character in the Camera IDShutter Speed Setting Shutter Gain Control Setting AGC on DNR-L, DNR-H/OFFElectronic Sensitivity Enhancement Sens UP White Balance Setting White BAL Synchronization Setting SyncATW1 Auto-Tracing White Balance Manual Fine Adjustment for AWC ATW Motion Detector Setting Motion DETAutomatic White Balance Control Mode AWC Push SWMenu/DIP SW Selection Special Menu SpecialTo reset to the factory settings Camera Reset 10-6. BWNetwork Setup Network Setup Http Port NumberInitializing the Camera Menu Initializing the Setup MenuInitializing Initializing Html FilesTroubleshooting Prevention of Blooming and Smear SpecificationsTCP/IP, HTTP, FTP, SMTP, DNS, DDNS, DHCP, ARP, BOOTP, NTP Network SectionGeneral Standard AccessoriesOptional Accessories WV-NW474SEAppendix Optional Heater Unit WV-CW3HE在日本印刷