Panasonic WV-NW470S, WV-NW474SE Network Setup of the Camera, Using Panasonic IP Setup Software

Page 16

7.Click the "Use the following IP address" radio button and enter the IP address and the subnet mask as follows.

IP address

: 192.168.0.9

Subnet mask

: 255.255.255.0

8.Click the [OK] button, and the window dialog box closes.

Note: Use a small sized picture when a blue picture appears instead of the live picture due to Internet traffic congestion.

Network Setup of the Camera

Using Panasonic IP Setup Software

Set up the network of the camera using the "Panasonic IP Setup" software included on the CD-ROM provided with the camera.

Notes:

Do not access this menu through HTML or con- trollers during the Panasonic IP Setup procedure.

Only one administrator is required.

If a firewall (including software) exists, allow access to all UDP ports. Otherwise, it is impossible to use the "Panasonic IP Setup" software.

Double-click IP setup.exe.

The "Panasonic IP Setup" starts up.

The MAC address and the IP address of the connected camera will be displayed. (Click the [REFRESH] button if they are not displayed.)

1.Click the MAC ADDRESS/IP ADDRESS of the cam- era to be set up.

2.Click the [NETWORK SETUP] button. The setup window appears.

Notes:

When two or more cameras are connected, the MAC addresses and the IP addresses of all the connected cameras will be displayed.

The "Panasonic IP Setup" software can recognize only those cameras in the same subnet.

Pressing the [REFRESH] button will display the updated MAC addresses and IP addresses of all the connected cameras that are in the same sub- net.

3. Set parameters for each item.

"IP Address"

"Subnet Mask" "Default Gateway" "HTTP Port"

4.Input the parameters for your environment. "DHCP" "DNS"

-16-

Image 16
Contents WV-NW474SE Risk of Electric Shock Do not Open Contents Features PrefaceSystem Requirements TrademarksDocument Convention Precautions Handle the camera with careNever face the camera towards the sun Do not aim the camera at the same object for a long timeMajor Operating Controls & Their Functions 8DIP switch @3Control connector@4Power cable @2Video output connectorInstallation Installation Plans & PreparationsInstallation space ProcurementMounting the Camera Optional Heater UnitPower Connection Wire colours & functions AC TypeCable length and wire gauge 24 V AC Type ConnectionsImage Adjustment Control ConnectorVideo Output Connection Network Port ConnectionWaterproof Process Network Connection Types Direct Connection to PC TypeConnection to Intranet Type Connection to Internet TypeNetwork Setup of Your PC Preparations for Network ConnectionsNetwork Setup of the Camera Using Panasonic IP Setup SoftwareDhcp DNS DdnsPage Prior to Camera Setup Buttons Used for SetupCamera Setup Menus ALL Reset button¡From the Camera Setup Menu Tree Setting Procedures Setup SelectionCamera Setup Menu CAM Camera Identification Camera ID SettingLight Control Setting ALC Command UsageTo edit the Camera ID To replace a specific character in the Camera IDShutter Speed Setting Shutter Gain Control Setting AGC on DNR-L, DNR-H/OFFElectronic Sensitivity Enhancement Sens UP White Balance Setting White BAL Synchronization Setting SyncATW1 Auto-Tracing White Balance Motion Detector Setting Motion DET Automatic White Balance Control Mode AWCManual Fine Adjustment for AWC ATW Push SWMenu/DIP SW Selection Special Menu SpecialTo reset to the factory settings Camera Reset 10-6. BWNetwork Setup Network Setup Http Port NumberInitializing the Setup Menu InitializingInitializing the Camera Menu Initializing Html FilesTroubleshooting Specifications TCP/IP, HTTP, FTP, SMTP, DNS, DDNS, DHCP, ARP, BOOTP, NTPPrevention of Blooming and Smear Network SectionStandard Accessories Optional AccessoriesGeneral WV-NW474SEAppendix Optional Heater Unit WV-CW3HE在日本印刷