Panasonic WV-NW470S, WV-NW474SE operating instructions Precautions, Handle the camera with care

Page 6

PRECAUTIONS

1.This product should be installed and connected in conformity with local codes by qualified serv- ice personnel or system installers.

2.Use a class 2 power source supplying 24 V AC.

3.To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) to connect the power supply to the camera.

4.Be sure to use a ceiling board/wall having enough strength to support this camera.

5.Do not attempt to disassemble the camera.

To prevent electric shock, do not remove screws or covers.

There are no user-serviceable parts inside. Ask a qualified service personnel for servicing.

6.Handle the camera with care.

Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage.

7.Do not use strong or abrasive detergents when cleaning the camera body.

Use a dry cloth to clean the camera when it is dirty. When the dirt is hard to remove, use a mild deter- gent and wipe gently. Care should be taken not to scratch the dome cover when wiping it.

Wipe off any remaining detergent in it with a dry cloth.

8.Never face the camera towards the sun.

Whether the camera is in use or not, never aim it at the sun or other extremely bright objects. Otherwise, blooming or smear may be caused.

9.Never aim the camera at strong light sources for an extended period of time.

A light source such as a spot light causes burn-in on the display screen. Failure to observe this may cause the image to become discoloured due to deterioration of the colour filter in the CCD.

10.Do not operate the camera beyond the specified temperature, humidity or power source ratings. Do not use the camera in an extreme environment where high temperature or high humidity exists. Do not place the camera near heat sources such as radiators, stoves or other units that produce heat. Use the camera under conditions where tempera- tures are between –10 °C and +50 °C (14 °F to 122 °F) and humidity is below 90 %.

The input power source is 24 V AC 50 Hz for WV- NW474SE or 220 V - 240 V AC 50 Hz for WV-NW 470S.

-6-

11.Do not install the camera near the air outlet of an air conditioner.

The lens may become cloudy due to condensation if the camera is used under the following conditions.

Rapid temperature fluctuations by switching the air conditioner on and off.

Rapid temperature fluctuations due to frequent opening and closing of a door.

Use in an environment where eyeglasses become foggy.

Use in a room filled with cigarette smoke or dust. If the lens becomes cloudy due to condensation, remove the dome cover and wipe all moist surfaces with a soft cloth.

When installing, be sure to wipe off water drops and splashes inside the camera. Failure to do so may cause condensation.

12.Do not aim the camera at the same object for a long time.

Burn-in of an image may be caused on the fluores- cent screen of the CRT.

Matsushita Electric Industrial Co., Ltd. herewith declares that it will not be liable for any damage, whether direct or indirect, caused by using the product for business transactions or security, or malfunctioning of this product.

Image 6
Contents WV-NW474SE Risk of Electric Shock Do not Open Contents System Requirements FeaturesPreface TrademarksDocument Convention Never face the camera towards the sun PrecautionsHandle the camera with care Do not aim the camera at the same object for a long timeMajor Operating Controls & Their Functions @4Power cable 8DIP switch@3Control connector @2Video output connectorInstallation space InstallationInstallation Plans & Preparations ProcurementMounting the Camera Optional Heater UnitCable length and wire gauge 24 V AC Type Power ConnectionWire colours & functions AC Type ConnectionsVideo Output Connection Image AdjustmentControl Connector Network Port ConnectionWaterproof Process Connection to Intranet Type Network Connection TypesDirect Connection to PC Type Connection to Internet TypeNetwork Setup of Your PC Preparations for Network ConnectionsNetwork Setup of the Camera Using Panasonic IP Setup SoftwareDhcp DNS DdnsPage Camera Setup Menus Prior to Camera SetupButtons Used for Setup ALL Reset button¡From the Camera Setup Menu Tree Camera Setup Menu CAM Setting ProceduresSetup Selection Camera Identification Camera ID SettingTo edit the Camera ID Light Control Setting ALCCommand Usage To replace a specific character in the Camera IDGain Control Setting AGC on DNR-L, DNR-H/OFF Shutter Speed Setting ShutterElectronic Sensitivity Enhancement Sens UP Synchronization Setting Sync White Balance Setting White BALATW1 Auto-Tracing White Balance Manual Fine Adjustment for AWC ATW Motion Detector Setting Motion DETAutomatic White Balance Control Mode AWC Push SWMenu/DIP SW Selection Special Menu SpecialTo reset to the factory settings Camera Reset 10-6. BWNetwork Setup Network Setup Http Port NumberInitializing the Camera Menu Initializing the Setup MenuInitializing Initializing Html FilesTroubleshooting Prevention of Blooming and Smear SpecificationsTCP/IP, HTTP, FTP, SMTP, DNS, DDNS, DHCP, ARP, BOOTP, NTP Network SectionGeneral Standard AccessoriesOptional Accessories WV-NW474SEAppendix Optional Heater Unit WV-CW3HE在日本印刷