Panasonic WV-CS854B operating instructions Zoom →PUSH SET RET

Page 24

This determines the starting point and the cursor moves to END.

** AUTO PAN **

 

 

START

 

POSITION

 

 

SPEED

END

••••

••••

 

 

L

H

ENDLESS

OFF

 

DWELL TIME

1S

 

PAN LIMIT

OFF

 

ZOOM LIMIT

OFF

 

RET

(3)Move the joystick to select a panning endpoint and press the CAM (SET) key.

This determines the endpoint and the cursor moves to POSITION.

4.To set a panning speed

Move the cursor to SPEED, and set a panning speed with the joystick.

** AUTO PAN **

 

POSITION

START

 

SPEED

END

 

••••••••

 

L

H

ENDLESS

OFF

 

DWELL TIME

1S

 

PAN LIMIT

OFF

 

ZOOM LIMIT

OFF

 

RET

The panning speed increases when the joystick is moved to the right, and decreases when it is moved to the left.

Caution: If the panning range is changed after the camera has not panned for a long time or has been panning in the same panning range, the picture may not be clear or noise may appear. In such cases, pan the camera fully several times.

If this does not eliminate the problem, refer servicing to qualified service personnel.

5.To set ENDLESS to ON/OFF

Move the cursor to ENDLESS, and select ON or OFF with the joystick.

** AUTO PAN **

 

POSITION

START

 

 

END

 

SPEED

••••••••

 

L

H

ENDLESS

ON

 

 

DWELL TIME

1S

 

PAN LIMIT

OFF

 

ZOOM LIMIT

OFF

 

RET

ON: The camera pans from the starting point to the endpoint, and keeps rotating in the same direction to return to the starting point. Set PAN LIMIT to OFF before ENDLESS is set to ON.

OFF: The camera pans from the starting point to the endpoint, and rotates backward to the starting point.

This movement is repeated over and over.

6.To set a dwell time

Move the cursor to DWELL TIME and select a dwell time with the joystick.

** AUTO PAN **

 

POSITION

START

 

 

END

 

SPEED

••••••••

 

L

H

ENDLESS

OFF

 

DWELL TIME

1S

 

 

PAN LIMIT

OFF

 

ZOOM LIMIT

OFF

 

RET

Dwell time changes as follows:

0S 1S 2S 3S

30S20S 10S 5S

7.To set pan limit ON/OFF

Move the cursor to PAN LIMIT and select ON or OFF with the joystick.

The factory default setting is OFF.

ON: Manual pan is limited from the starting point to the endpoint specified by position setting. Set ENDLESS to OFF before PAN LIMIT is set to ON.

OFF: Manual pan is not limited.

Note: When ON is selected for PAN LIMIT, manual pan moves the camera away from the other side (PAN LIMIT) of the start-end range.

8.To set zoom limit ON/OFF

Move the cursor to ZOOM LIMIT and select ON or OFF with the joystick.

 

** ZOOM LIMIT **

ZOOM

 

 

 

PUSH SET

RET

ON: Limits the manual zoom operation by following the procedure below.

(1)Move the cursor to ZOOM LIMIT, select ON and press the CAM (SET) key.

The ZOOM LIMIT setting menu appears.

-24-

Image 24
Contents Color Cctv Camera English Version Important Safety Instructions EnglishPage Contents Features PrefaceDigital Flip Operation Precautions Camera CleaningPreset Data Uploading or Down Loading Consumables Do not aim the camera at the same object for a long timeSelf-diagnosis Function Prevention of blooming and smearConstruction Setup Setup MenuAUTO/ON/OFF P Preset ID MON ESC CAM SETWV-CU161C WV-RM70 Prog SWSetup Menu Description Camera Shutter Speed Shutter Gain Control AGCSynchronization Sync Important NoticesAuto Focus AF Mode RS485 Communication10Special 2 Menu SPECIAL2 11Self-diagnosis FunctionSetting Procedures Setup Menu DisplayMenu Display Submenu DisplayPreset Menu Preset Menu DisplayPosition Setting Position SET To Set Panning/Tilting PositionsPan Offset To Set the Lens Zoom and Focus PositionsPreset Identification Setting Preset ID Light Control Setting ALC/MANUAL Scene File Setting Scene FileTo Return to the Preset Setting Menu Dwell Time Dwell TimeDeleting Preset Positions Preset Speed Setting Preset SpeedTo Return to the Preset Number Set Menu To Return to the Setup MenuHome Position Setting Home Self Return Setting SelfAuto Mode Selection Auto OFF SEQ Sort Auto PAN PatrolZoom →PUSH SET RET Auto Pan Key Setting Auto PAN KEY Digital Flip Setting Digital FlipSEQ Sort Patrol New Password Password VerificationSpecial 1 Menu Setting Special Privacy Zone Privacy ZoneSettings for on Nesw Proportional Pan/Tilt PROPO. P/TArea Title Area Title Zoom ratioSetting for on User Area Title EditingPatrol-learn and Patrol Play Patrol To Quit EditingPatrol Learn with a Controller Having Patrol Key PAN/TILT/ZOOM/FOCUS Iris Shutter AGC Sens UP White BalanceAlarm Input/Output Alarm IN/OUT Patrol Play with a Controller Having the Patrol KeyPatrol Play with a Controller not Having the Patrol Key Patrol Play with the Auto PAN KeyCleaning Cleaning Electronic Zoom EL-ZOOMCNT-CLS 1, 2 Output Preset Alarm Preset ALM Image Hold Image HoldTilt Angle Tilt Angle 0 /5 Camera Setting To Display the Camera Setting MenuCamera Identification Camera ID ALC Mode with SUPER-D2 on Shutter Speed Setting Shutter Gain Control AGC on LOW/ MID/ HIGH/OFFElectronic Sensitivity Enhancement Sens UP Line-lock Sync Mode LL Synchronization SyncAuto-Tracing White Balance Mode ATW1/ ATW2 Automatic White Balance Control Mode AWCWhite Balance White BAL Motion Detector Motion DET Auto Focus Setting AF Mode Resolution ResolutionSpecial 2 Menu SPECIAL2 Auto S Auto M Auto L Manual L Manual M Manual SBlack and White Mode BW Mode BW SettingPIX Sens UP Setting Burst BW SettingPIX OFF Setting PIX OFF Camera Resetting Camera ResetTo Restore the Camera Default Position Refresh Reset to the Factory Default SettingsRS485 Setup Initial Camera Communication ParametersChanging the Camera Communication Parameters Factory Default Setting Menu SettingPreset Menu Preset ID ALC/MANUAL SUPER-D2 OFF Dwell Time CNT-CLS OFF Coax ALM OUTInstallation Setting the SwitchesPrecautions RS485 Parameter SetupFor Panasonic’s Protocol Unit NumberUnit RS485 Setting Assemble the CameraSideway Cable Exit Hook the fall prevention wire on the camera mounting base Accessory Connector Information How to Assemble the Cable with the Accessory ConnectorConnect this to 24 V AC Class 2 Power Supply only ConnectionsAlarm in Connections Alarm OUT ConnectionsRS485 Connection OUTSystem Connections Specifications WV-CS854BAccessories Optional AccessoriesWV-CS2SH Appendix ShortcutsImprimé au Japon