Panasonic WV-CS854B operating instructions RS485 Setup, Initial Camera Communication Parameters

Page 43

For WV-RM70, hold down the right and left switches simultaneously for 2 seconds or more.

For WV-CU360C/CJ and WV-CU161C, hold down the [4] and [6] keys simultaneously for 2 seconds or more.

Data Bit (DATA BIT)

Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory default setting is 8.

Parity Check (PARITY CHECK)

Specifies the parity check mode (NONE, ODD, EVEN). The factory default setting is NONE.

RS485 Setup

Initial Camera Communication Parameters

In an RS485 chain, the matrix switcher, PC, controllers and cameras should be set to the same protocol and parameters for communication. Confirm the system protocol and parameters prior to setting the communication parameters for the camera.

The initial communication parameters for WV-CS854B are shown on the RS485 setup menu below. Other than the on-screen setup parameters, the 4-bit DIP switch may be used to select 2-line (half duplex) or 4-line (full duplex) communication.

Changing the Camera Communication Parameters

You can remotely control this camera by using a specified extension unit such as a computer with a modem.

1.Display SET UP MENU. Move the cursor to RS485 SET UP and press the CAM (SET) key. The RS485 SET UP menu appears on the monitor.

** RS485 SET UP **

UNIT NUMBER

1

 

SUB ADDRESS

1

 

BAUD RATE

19200

DATA BIT

8

 

PARITY CHECK

NONE

STOP BIT

1

 

XON/XOFF

NOT USE

WAIT TIME

OFF

ALARM DATA

AUTO2

DELAY TIME

OFF

RET

 

 

2.Move the cursor to the item and select the parameter with the joystick.

Unit Number (UNIT NUMBER)

Displays the unit number set by the DIP switch. If the switch is set to 1-96, select a number with the joystick. In an RS485 chain each unit must have a unique number.

Factory default setting: 1. See INSTALLATION for DIP switch setting.

Sub Address (SUB ADDRESS)

Do not set.

Baud Rate (BAUD RATE)

Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communication. The factory default setting is 19 200.

Stop Bit (STOP BIT)

Specifies the number of stop bits (1 or 2 bits). The factory default setting is 1.

X ON/X OFF (X ON/X OFF)

Specifies whether to apply flow control or not (USE or NOT USE). The factory default setting is NOT USE.

Wait Time (WAIT TIME)

Specifies the time to wait until retrying after confirming that no data is received from the controller.

(OFF: no retry, 100, 200, 400, 1 000 ms).

Alarm Data (ALARM DATA)

Specifies the alarm transmission mode depending on the protocol selected by the 8-bit DIP switch.

POLLING: Transmits the alarm data in response to requests from the controller.

AUTO 1: Transmits the alarm data each time an alarm signal is received by the camera.

AUTO 2 (Default): Transmits alarm data at intervals of 5 seconds.

Delay Time (DELAY TIME)

Specifies the time to transmit the acknowledge request when communicating on a 2-line connection.

[----, 100 ms] Factory default setting: ---- (no set).

This menu appears only when a 2-line communication is used. Make sure to be 100 ms when connecting the camera with WJ-FS616 Video Multiplexer or Matrix Switcher WJ-SX350 in a 2-line communication system.

The settings become effective with the closing of SET UP MENU.

Note: Set the same parameters for the cameras, controllers and personal computers in an RS485 chain.

-43-

Image 43
Contents Color Cctv Camera English Version English Important Safety InstructionsPage Contents Preface FeaturesDigital Flip Operation Camera Cleaning PrecautionsPreset Data Uploading or Down Loading Prevention of blooming and smear ConsumablesDo not aim the camera at the same object for a long time Self-diagnosis FunctionConstruction Setup Menu SetupAUTO/ON/OFF P Prog SW Preset IDMON ESC CAM SET WV-CU161C WV-RM70Setup Menu Description Camera Important Notices Shutter Speed ShutterGain Control AGC Synchronization Sync11Self-diagnosis Function Auto Focus AF ModeRS485 Communication 10Special 2 Menu SPECIAL2Submenu Display Setting ProceduresSetup Menu Display Menu DisplayTo Set Panning/Tilting Positions Preset MenuPreset Menu Display Position Setting Position SETTo Set the Lens Zoom and Focus Positions Pan OffsetPreset Identification Setting Preset ID Dwell Time Dwell Time Light Control Setting ALC/MANUALScene File Setting Scene File To Return to the Preset Setting MenuTo Return to the Setup Menu Deleting Preset PositionsPreset Speed Setting Preset Speed To Return to the Preset Number Set MenuOFF SEQ Sort Auto PAN Patrol Home Position Setting HomeSelf Return Setting Self Auto Mode Selection AutoZoom →PUSH SET RET Digital Flip Setting Digital Flip Auto Pan Key Setting Auto PAN KEYSEQ Sort Patrol Password Verification New PasswordPrivacy Zone Privacy Zone Special 1 Menu Setting SpecialZoom ratio Settings for on NeswProportional Pan/Tilt PROPO. P/T Area Title Area TitleArea Title Editing Setting for on UserPAN/TILT/ZOOM/FOCUS Iris Shutter AGC Sens UP White Balance Patrol-learn and Patrol Play PatrolTo Quit Editing Patrol Learn with a Controller Having Patrol KeyPatrol Play with the Auto PAN Key Alarm Input/Output Alarm IN/OUTPatrol Play with a Controller Having the Patrol Key Patrol Play with a Controller not Having the Patrol KeyElectronic Zoom EL-ZOOM Cleaning CleaningCNT-CLS 1, 2 Output Image Hold Image Hold Preset Alarm Preset ALMTilt Angle Tilt Angle 0 /5 To Display the Camera Setting Menu Camera SettingCamera Identification Camera ID ALC Mode with SUPER-D2 on Gain Control AGC on LOW/ MID/ HIGH/OFF Shutter Speed Setting ShutterElectronic Sensitivity Enhancement Sens UP Synchronization Sync Line-lock Sync Mode LLAutomatic White Balance Control Mode AWC Auto-Tracing White Balance Mode ATW1/ ATW2White Balance White BAL Motion Detector Motion DET Auto S Auto M Auto L Manual L Manual M Manual S Auto Focus Setting AF ModeResolution Resolution Special 2 Menu SPECIAL2Burst BW Setting Black and White Mode BW ModeBW Setting PIX Sens UP SettingReset to the Factory Default Settings PIX OFF Setting PIX OFFCamera Resetting Camera Reset To Restore the Camera Default Position RefreshInitial Camera Communication Parameters RS485 SetupChanging the Camera Communication Parameters CNT-CLS OFF Coax ALM OUT Factory Default SettingMenu Setting Preset Menu Preset ID ALC/MANUAL SUPER-D2 OFF Dwell TimeRS485 Parameter Setup InstallationSetting the Switches PrecautionsUnit Number For Panasonic’s ProtocolUnit Assemble the Camera RS485 SettingSideway Cable Exit Hook the fall prevention wire on the camera mounting base Connections Accessory Connector InformationHow to Assemble the Cable with the Accessory Connector Connect this to 24 V AC Class 2 Power Supply onlyOUT Alarm in ConnectionsAlarm OUT Connections RS485 ConnectionSystem Connections WV-CS854B SpecificationsOptional Accessories AccessoriesWV-CS2SH Shortcuts AppendixImprimé au Japon