Icom IC-R3 Selecting a memory channel, Attenuator function, Lock function, Tion on and OFF

Page 13

Selecting a memory channel

q Push [V/M] to select memory

FM

mode.

 

• “X” or “M:” appears when a mem-

P

ory channel is selected.

 

FREQUENCY AND CHANNEL SETTING 3

Attenuator function

The attenuator prevents a desired signal from distorting when very strong signals are near the desired frequency or when very strong electric fields, such as from a broadcasting sta- tion, are near your location.

wRotate [DIAL] to change the indi- cated memory channel.

Only programmed memory chan- nels can be selected.

Rotate [DIAL] while pushing [FUNC] to change the memory bank.

[DIAL] changes the memory channel.

FM

P

While pushing [FUNC], [DIAL] changes the memory bank.

The receiver has 4 attenuation levels for various operating conditions. The attenuator functions when the operating fre- quency is 1149.995 MHz or below.

qPush [FUNC] + [(SQL) ATT] to enter the attenuator setting condition.

w Rotate [DIAL] to set the attenuation level 1–4 or turn the

attenuator function OFF.

• “ATT1” – “ATT4” appears in the color LCD when the color LCD is

Lock function

The lock function prevents accidental frequency changes and accidental function access.

Push [FUNC] + [MODE] for 2 sec. to toggle the lock func-

ON; “ATT” appears in the sub display when the color LCD is

OFF.

ePush [(SQL) ATT] to exit the attenuator setting condition.

Shows when the attenuator

(level 4) is in use.

tion ON and OFF.

[POWER], [(VOL)] and [SQL] can still be accessed while the lock function is ON (default).

Accessible switches can be set to 1 of 4 groups in set mode. See p. 42 for details.

FM

L ” appears when the lock function is in use.

FM

FM

 

 

 

 

ATT4

 

 

 

 

 

 

 

 

 

 

 

 

 

145.000.000

ATT

TS

 

 

 

15.0

 

Shows when the attenuator

S1

3

5

7

9

 

 

 

 

 

 

 

 

 

is in use.

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Image 13 Icom IC-R3 instruction manual Selecting a memory channel, Attenuator function, Lock function, Tion on and OFF
Contents IR3 Areas with temperatures below -10C +14F or above You experience a ringing in your ears, reduce the volumeEven when the receiver power is OFF, a slight current still +60C +140FAccessories included with the receiver Qty Supplied AccessoriesTable of Contents Battery installation Accessory AttachmentAntenna Belt clipPanel description Panel DescriptionMode Switch Mode SET VFO/MEMORY Switch V/M SkipMonitor Switch SQL ATT External DC Power Jack DCFunction display Battery Indicators Skip Scan Indicator pgs2ATTENUATOR Indicator p Audio and video output jack informationDual LCD What is VFO? Frequency and Channel SettingVFO and memory channels Operating band selectionSetting a tuning step Setting a frequencySelecting a memory channel Push SQL ATT to exit the attenuator setting conditionAttenuator function Lock functionBasic Operation When a signal is receivedReceiving U.S.A. version automatically turns itself OFF whenSetting squelch level Setting volume levelWhile pushing SQL, rotate Dial to select the squelch levelMonitor function Receive mode selectionPush Func + Mode SET momentarily to enter set mode Setting the backlighting conditionDisplay backlighting Rotate Dial until Light appearsMemory Channels Memory channel contentsGeneral Programming during selectionProgramming after selection Transferring memory contents to another memoryPush Func + V/M for 2 sec. to clear Memory bank selection Memory clearExample Clearing memory channel 3 memory bank a Memory names Rotate the tuning dial to select the desired characterScan types Scan OperationFull Scan p Function pRelease ↔ to start the scan Full/band/programmed scanTo stop the scan, push ↔ again Memory bank scanBand ranges Selecting scan edgesSetting the scan pause time Skip channel settingScan resume condition Rotate Dial until Pause Scan or Pause appearsRotate Dial until Scan Resume or RESUmE appears Setting the scan resume timeProgramming a skip frequency Frequency skip functionFrequency skip function ON/OFF Priority watch types Priority WatchMemory Scan Watch p VFO Scan Watch pPriority watch operation Push Mode SET to exit set mode and start the watchMemory channel watch and memory scan Watch Rotate Dial to select Priority or PRIoVFO scan watch Subaudible Tone Operation Setting subaudible tones for tone squelch OperationTone squelch operation OperationRotate Dial until Tone Freq. or tonE appears Pocket beep operationAvailable subaudible tone frequencies Unit Hz Push SQL to stop the beeps and flashing Tone scanPush ↔ to stop the scan Duplex shift direction Duplex OperationRotate Dial until Duplex or dUP appears Rotate Dial until Offset Freq. or oFFSEt appears Offset frequencyRange, if desired Band ScopeTV Operation Skip channel settingTV operation TV channel receivingTV frequency AM TV memory channel TV frequency AM TV receivingPush ↔ one or more times to select the band above 30 MHz Push Func + one or more times to select the TV screenATV operation Sub carrier adjustmentATV memory channel Signal levels Signal sourceDirection Finding Direction finding function exampleSet mode items Set modeOther Functions Dial select step Setting dial select stepRelease Func to exit the condition Rotate Dial until A.Power OFF or AP oFF appears Auto power-off functionBeep tones Rotate Dial until Beep Audio or bEEP appearsMonitor switch action Power saverRotate Dial until Power Save or P Save appears Rotate Dial until Monitor or monI appearsLock function effect Dial speed accelerationRotate Dial until Dial Speedup or SPEEd appears Rotate Dial until Key Lock or LoCk appearsColor LCD can be automatically turned on when using Display mode selectionDisplay contrast Rotate Dial until Display or dISP appearsDisplay background color Display brightnessRotate Dial until Bright appears Total reset Partial resetPush Power for 2 sec. to turn power OFF Cloning functionBattery cautions Battery ChargingBattery charging Battery pack installationTurn power OFF Check CP-18A/E fuse ReplacementCP-18A/ERegular charging Rapid charging with the BC-135Memory mode VFO mode Operation Flow ChartAuto power OFF p Confirmation beep p Backlighting p Power save pScan resume time p A. channels TV Frequency TableCcir channels Taiwan channels Australian channelsNew Zealand channels Indonesian channels China channelsItalian channels FOT channels General Specifications and OptionsReceiver Options Operating periods ApproxProblem Possible Cause Solution TroubleshootingQuick Reference Quick Reference Declaration of Conformity Kamihigashi, Hirano-ku, Osaka 547-0002 Japan