Icom IC-R3 instruction manual Programming a skip frequency, Frequency skip function ON/OFF

Page 28

6 SCAN OPERATION

Frequency skip function

Programming a skip frequency

Unwanted frequencies can be skipped and programmed as skip channels when full scan, band scan or programmed scan is pausing.

qStart full scan, band scan or programmed scan. (p. 19) w While receiving an unwanted signal and scan pauses,

push [FUNC] + [(V/M) SKIP] for 2 sec. to program the re- ceived frequency as a skip frequency.

The receiver emits 3 beeps and the scan resumes.

Non-programmed memory channels (blank channels) are used for skip frequency programming in reverse sequence.

To scan the skip frequency after programming, cancel the skip information (p. 22) or clear the memory channel (p. 16).

FM

PSKIP

FM

PSKIP

 

2P

 

H49

370.475.000

370.475.000

TS

15.0

TS

15.0

S1

3

5

7 9

S1

3

 

5

7

9

RX

 

 

 

 

 

 

 

 

RX

 

 

 

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

 

 

 

 

 

 

FM

 

 

 

 

 

 

 

RX

 

 

P

 

RX

 

 

P

 

 

Indication while pausing

Indication while programming

Frequency skip function ON/OFF

The frequency skip function can be turned OFF. In this case, the frequencies will not be skipped even if skip information is programmed and “P SKIP” or “P ” does not appear.

qSelect VFO mode with [V/M].

wPush [FUNC] + [(V/M) SKIP] to toggle the frequency skip function ON or OFF.

• “PSKIP” or “P ” appears when the function is turned ON.

FM

 

 

 

 

 

 

FM

 

 

 

 

 

 

PSKIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

146.010.000

146.010.000

TS

 

 

 

15.0

TS

 

 

 

15.0

 

S1

3

5

7 9

S1

3

 

 

 

7

9

5

VOL

 

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

 

 

 

 

 

 

FM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

The frequency skip

The frequency skip

function is OFF.

function is ON.

 

24

Image 28 Icom IC-R3 instruction manual Programming a skip frequency, Frequency skip function ON/OFF
Contents IR3 You experience a ringing in your ears, reduce the volume Areas with temperatures below -10C +14F or aboveEven when the receiver power is OFF, a slight current still +60C +140FSupplied Accessories Accessories included with the receiver QtyTable of Contents Accessory Attachment Battery installationAntenna Belt clipPanel Description Panel descriptionVFO/MEMORY Switch V/M Skip Mode Switch Mode SETMonitor Switch SQL ATT External DC Power Jack DCFunction display Skip Scan Indicator pgs Battery Indicators2ATTENUATOR Indicator p Audio and video output jack informationDual LCD Frequency and Channel Setting What is VFO?VFO and memory channels Operating band selectionSetting a frequency Setting a tuning stepPush SQL ATT to exit the attenuator setting condition Selecting a memory channelAttenuator function Lock functionWhen a signal is received Basic OperationReceiving U.S.A. version automatically turns itself OFF whenSetting volume level Setting squelch levelWhile pushing SQL, rotate Dial to select the squelch levelReceive mode selection Monitor functionSetting the backlighting condition Push Func + Mode SET momentarily to enter set modeDisplay backlighting Rotate Dial until Light appearsMemory channel contents Memory ChannelsGeneral Programming during selectionTransferring memory contents to another memory Programming after selectionPush Func + V/M for 2 sec. to clear Memory bank selection Memory clearExample Clearing memory channel 3 memory bank a Rotate the tuning dial to select the desired character Memory namesScan Operation Scan typesFull Scan p Function pFull/band/programmed scan Release ↔ to start the scanMemory bank scan To stop the scan, push ↔ againSelecting scan edges Band rangesSkip channel setting Setting the scan pause timeScan resume condition Rotate Dial until Pause Scan or Pause appearsSetting the scan resume time Rotate Dial until Scan Resume or RESUmE appearsProgramming a skip frequency Frequency skip functionFrequency skip function ON/OFF Priority Watch Priority watch typesMemory Scan Watch p VFO Scan Watch pPush Mode SET to exit set mode and start the watch Priority watch operationMemory channel watch and memory scan Watch Rotate Dial to select Priority or PRIoVFO scan watch Setting subaudible tones for tone squelch Operation Subaudible Tone OperationTone squelch operation OperationRotate Dial until Tone Freq. or tonE appears Pocket beep operationAvailable subaudible tone frequencies Unit Hz Push SQL to stop the beeps and flashing Tone scanPush ↔ to stop the scan Duplex shift direction Duplex OperationRotate Dial until Duplex or dUP appears Offset frequency Rotate Dial until Offset Freq. or oFFSEt appearsBand Scope Range, if desiredSkip channel setting TV OperationTV operation TV channel receivingTV frequency AM TV receiving TV frequency AM TV memory channelPush ↔ one or more times to select the band above 30 MHz Push Func + one or more times to select the TV screenATV operation Sub carrier adjustmentATV memory channel Signal source Signal levelsDirection Finding Direction finding function exampleSet mode items Set modeOther Functions Dial select step Setting dial select stepRelease Func to exit the condition Auto power-off function Rotate Dial until A.Power OFF or AP oFF appearsBeep tones Rotate Dial until Beep Audio or bEEP appearsPower saver Monitor switch actionRotate Dial until Power Save or P Save appears Rotate Dial until Monitor or monI appearsDial speed acceleration Lock function effectRotate Dial until Dial Speedup or SPEEd appears Rotate Dial until Key Lock or LoCk appearsDisplay mode selection Color LCD can be automatically turned on when usingDisplay contrast Rotate Dial until Display or dISP appearsDisplay background color Display brightnessRotate Dial until Bright appears Partial reset Total resetPush Power for 2 sec. to turn power OFF Cloning functionBattery Charging Battery cautionsBattery charging Battery pack installationCP-18A/E fuse ReplacementCP-18A/E Turn power OFF CheckRegular charging Rapid charging with the BC-135Operation Flow Chart Memory mode VFO modeAuto power OFF p Confirmation beep p Backlighting p Power save pScan resume time p A. channels TV Frequency TableCcir channels Taiwan channels Australian channelsNew Zealand channels China channels Indonesian channelsItalian channels FOT channels General Specifications and OptionsReceiver Operating periods Approx OptionsTroubleshooting Problem Possible Cause SolutionQuick Reference Quick Reference Declaration of Conformity Kamihigashi, Hirano-ku, Osaka 547-0002 Japan