Icom IC-R3 Power saver, Monitor switch action, Rotate Dial until Power Save or P Save appears

Page 45

Power saver

The power saver function reduces the current drain to con- serve battery power.

qPush [FUNC] + [(MODE) SET] momentarily to enter set mode.

• Select a non-band scope screen in advance for color LCD.

wRotate [DIAL] until “Power Save” or “P SAVE” appears.

“P SAVE” disappears after 1 sec. and “PS” appears when color LCD is OFF.

ePush [] or rotate the tuning dial while pushing [FUNC] to turn the power saver ON (AUTO) or OFF.

rPush [(MODE) SET] to exit set mode.

Power Save

:

AUTO

Power Save

:

AUTO

 

Power Save

:

OFF

Monitor

:

PUSH

Monitor

:

PUSH

 

Monitor

:

PUSH

Dial Speedup:

ON

Dial Speedup:

ON

 

Dial Speedup:

ON

Key Lock

: NORMAL

Key Lock

: NORMAL

 

Key Lock

: NORMAL

Display

:

AUTO

Display

:

AUTO

 

Display

:

AUTO

Power save set

Power saver ON

Power saver OFF

mode

(AUTO)

 

OTHER FUNCTIONS 13

Monitor switch action

The monitor switch can be set as a ‘sticky’ switch. When set to the sticky condition, each push of [SQL] toggles the moni- tor function on and off.

qPush [FUNC] + [(MODE) SET] momentarily to enter set mode.

• Select a non-band scope screen in advance for color LCD.

wRotate [DIAL] until “Monitor” or “monI” appears.

“monI” disappears after 1 sec. and “mo” appears when color LCD is OFF.

ePush [] or rotate the tuning dial while pushing [FUNC] to set the monitor switch to sticky (HOLD) or normal (PUSH).

rPush [(MODE) SET] to exit set mode.

Power Save

:

AUTO

 

Power Save

:

AUTO

 

Power Save

:

AUTO

Monitor

:

PUSH

 

Monitor

:

HOLD

 

Monitor

:

PUSH

Dial Speedup:

ON

 

Dial Speedup:

ON

 

Dial Speedup:

ON

Key Lock

: NORMAL

 

Key Lock

: NORMAL

 

Key Lock

: NORMAL

Display

:

AUTO

 

Display

:

AUTO

 

Display

:

AUTO

Monitor switch

‘Sticky’ action

‘Normal’ action

function set mode

 

 

41

Image 45
Contents IR3 Areas with temperatures below -10C +14F or above You experience a ringing in your ears, reduce the volumeEven when the receiver power is OFF, a slight current still +60C +140FAccessories included with the receiver Qty Supplied AccessoriesTable of Contents Battery installation Accessory AttachmentAntenna Belt clipPanel description Panel DescriptionMode Switch Mode SET VFO/MEMORY Switch V/M SkipMonitor Switch SQL ATT External DC Power Jack DCFunction display Battery Indicators Skip Scan Indicator pgs2ATTENUATOR Indicator p Audio and video output jack informationDual LCD What is VFO? Frequency and Channel SettingVFO and memory channels Operating band selectionSetting a tuning step Setting a frequencySelecting a memory channel Push SQL ATT to exit the attenuator setting conditionAttenuator function Lock functionBasic Operation When a signal is receivedReceiving U.S.A. version automatically turns itself OFF whenSetting squelch level Setting volume levelWhile pushing SQL, rotate Dial to select the squelch levelMonitor function Receive mode selectionPush Func + Mode SET momentarily to enter set mode Setting the backlighting conditionDisplay backlighting Rotate Dial until Light appearsMemory Channels Memory channel contentsGeneral Programming during selectionProgramming after selection Transferring memory contents to another memoryMemory bank selection Memory clear Push Func + V/M for 2 sec. to clearExample Clearing memory channel 3 memory bank a Memory names Rotate the tuning dial to select the desired characterScan types Scan OperationFull Scan p Function pRelease ↔ to start the scan Full/band/programmed scanTo stop the scan, push ↔ again Memory bank scanBand ranges Selecting scan edgesSetting the scan pause time Skip channel settingScan resume condition Rotate Dial until Pause Scan or Pause appearsRotate Dial until Scan Resume or RESUmE appears Setting the scan resume timeFrequency skip function Programming a skip frequencyFrequency skip function ON/OFF Priority watch types Priority WatchMemory Scan Watch p VFO Scan Watch pPriority watch operation Push Mode SET to exit set mode and start the watchMemory channel watch and memory scan Watch Rotate Dial to select Priority or PRIoVFO scan watch Subaudible Tone Operation Setting subaudible tones for tone squelch OperationTone squelch operation OperationPocket beep operation Rotate Dial until Tone Freq. or tonE appearsAvailable subaudible tone frequencies Unit Hz Tone scan Push SQL to stop the beeps and flashingPush ↔ to stop the scan Duplex Operation Duplex shift directionRotate Dial until Duplex or dUP appears Rotate Dial until Offset Freq. or oFFSEt appears Offset frequencyRange, if desired Band ScopeTV Operation Skip channel settingTV operation TV channel receivingTV frequency AM TV memory channel TV frequency AM TV receivingPush ↔ one or more times to select the band above 30 MHz Push Func + one or more times to select the TV screenSub carrier adjustment ATV operationATV memory channel Signal levels Signal sourceDirection Finding Direction finding function exampleSet mode Set mode itemsOther Functions Setting dial select step Dial select stepRelease Func to exit the condition Rotate Dial until A.Power OFF or AP oFF appears Auto power-off functionBeep tones Rotate Dial until Beep Audio or bEEP appearsMonitor switch action Power saverRotate Dial until Power Save or P Save appears Rotate Dial until Monitor or monI appearsLock function effect Dial speed accelerationRotate Dial until Dial Speedup or SPEEd appears Rotate Dial until Key Lock or LoCk appearsColor LCD can be automatically turned on when using Display mode selectionDisplay contrast Rotate Dial until Display or dISP appearsDisplay brightness Display background colorRotate Dial until Bright appears Total reset Partial resetPush Power for 2 sec. to turn power OFF Cloning functionBattery cautions Battery ChargingBattery charging Battery pack installationTurn power OFF Check CP-18A/E fuse ReplacementCP-18A/ERegular charging Rapid charging with the BC-135Memory mode VFO mode Operation Flow ChartConfirmation beep p Backlighting p Power save p Auto power OFF pScan resume time p TV Frequency Table A. channelsCcir channels Australian channels Taiwan channelsNew Zealand channels Indonesian channels China channelsItalian channels FOT channels Specifications and Options GeneralReceiver Options Operating periods ApproxProblem Possible Cause Solution TroubleshootingQuick Reference Quick Reference Declaration of Conformity Kamihigashi, Hirano-ku, Osaka 547-0002 Japan