Icom IC-R3 instruction manual Full/band/programmed scan, Release ↔ to start the scan

Page 23

Full/band/programmed scan

Scanning searches for signals automatically and makes it easier to locate new stations for listening purposes, etc.

qSelect VFO mode with [V/M].

wMake sure the squelch is set to the threshold point.

Select automatic squelch (AUTO) or a level (1–9) where the noise is just muted. (p. 10)

ePush and hold [], then rotate [DIAL] to select desired scan edge.

“ALL” for full scan, “BAND” for band scan or “PROG(RAM) 0” – “PROG(RAM)24” for programmed scan. (see the next page)

FM

 

 

PSKIP

FM

 

 

PSKIP

FM

 

 

PSKIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

146.100.000

146.100.000

146.100.000

TS

15.0

TS

15.0

TS

15.0

PROGRAM 0

BAND

 

 

 

ALL

 

 

 

S1 3

 

 

7 9

S1 3

 

 

7 9

S1 3

 

 

7 9

5

5

5

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programmed scan 0

Band scan

Full scan

SCAN OPERATION 6

rRelease [] to start the scan.

Decimal point(s) flashes while scanning.

“PSKIP” appears when the frequency skip function is turned ON. (p. 19)

“0P”–“24P” flash to indicate which pair of scan edges is being scanned.

To change the scanning direction, rotate [DIAL].

If the pocket beep function is activated, the receiver automati- cally selects the tone squelch function when a scan starts.

tTo stop the scan, push [] again.

If the same frequencies are programmed into a pair of scan edges, programmed scan does not start.

For programmed scan, scan edges must be programmed

in advance. Program scan edges in the same manner of

programming a memory channel (p. 14) and select a scan edge. (p. 21)

A tone scan function is available to search for subaudible

tones (e.g. when you want to find a subaudible tone fre-

quency necessary to open a repeater or to open the tone squelch). See p. 30 for details.

19

Image 23 Icom IC-R3 instruction manual Full/band/programmed scan, Release ↔ to start the scan
Contents IR3 +60C +140F You experience a ringing in your ears, reduce the volumeAreas with temperatures below -10C +14F or above Even when the receiver power is OFF, a slight current stillAccessories included with the receiver Qty Supplied AccessoriesTable of Contents Belt clip Accessory AttachmentBattery installation AntennaPanel description Panel DescriptionExternal DC Power Jack DC VFO/MEMORY Switch V/M SkipMode Switch Mode SET Monitor Switch SQL ATTFunction display Audio and video output jack information Skip Scan Indicator pgsBattery Indicators 2ATTENUATOR Indicator pDual LCD Operating band selection Frequency and Channel SettingWhat is VFO? VFO and memory channelsSetting a tuning step Setting a frequencyLock function Push SQL ATT to exit the attenuator setting conditionSelecting a memory channel Attenuator functionU.S.A. version automatically turns itself OFF when When a signal is receivedBasic Operation ReceivingDial to select the squelch level Setting volume levelSetting squelch level While pushing SQL, rotateMonitor function Receive mode selectionRotate Dial until Light appears Setting the backlighting conditionPush Func + Mode SET momentarily to enter set mode Display backlightingProgramming during selection Memory channel contentsMemory Channels GeneralProgramming after selection Transferring memory contents to another memoryExample Clearing memory channel 3 memory bank a Memory bank selection Memory clearPush Func + V/M for 2 sec. to clear Memory names Rotate the tuning dial to select the desired characterFunction p Scan OperationScan types Full Scan pRelease ↔ to start the scan Full/band/programmed scanTo stop the scan, push ↔ again Memory bank scanBand ranges Selecting scan edgesRotate Dial until Pause Scan or Pause appears Skip channel settingSetting the scan pause time Scan resume conditionRotate Dial until Scan Resume or RESUmE appears Setting the scan resume timeFrequency skip function ON/OFF Frequency skip functionProgramming a skip frequency VFO Scan Watch p Priority WatchPriority watch types Memory Scan Watch pRotate Dial to select Priority or PRIo Push Mode SET to exit set mode and start the watchPriority watch operation Memory channel watch and memory scan WatchVFO scan watch Operation Setting subaudible tones for tone squelch OperationSubaudible Tone Operation Tone squelch operationAvailable subaudible tone frequencies Unit Hz Pocket beep operationRotate Dial until Tone Freq. or tonE appears Push ↔ to stop the scan Tone scanPush SQL to stop the beeps and flashing Rotate Dial until Duplex or dUP appears Duplex OperationDuplex shift direction Rotate Dial until Offset Freq. or oFFSEt appears Offset frequencyRange, if desired Band ScopeTV channel receiving Skip channel settingTV Operation TV operationPush Func + one or more times to select the TV screen TV frequency AM TV receivingTV frequency AM TV memory channel Push ↔ one or more times to select the band above 30 MHzATV memory channel Sub carrier adjustmentATV operation Direction finding function example Signal sourceSignal levels Direction FindingOther Functions Set modeSet mode items Release Func to exit the condition Setting dial select stepDial select step Rotate Dial until Beep Audio or bEEP appears Auto power-off functionRotate Dial until A.Power OFF or AP oFF appears Beep tonesRotate Dial until Monitor or monI appears Power saverMonitor switch action Rotate Dial until Power Save or P Save appearsRotate Dial until Key Lock or LoCk appears Dial speed accelerationLock function effect Rotate Dial until Dial Speedup or SPEEd appearsRotate Dial until Display or dISP appears Display mode selectionColor LCD can be automatically turned on when using Display contrastRotate Dial until Bright appears Display brightnessDisplay background color Cloning function Partial resetTotal reset Push Power for 2 sec. to turn power OFFBattery pack installation Battery ChargingBattery cautions Battery chargingRapid charging with the BC-135 CP-18A/E fuse ReplacementCP-18A/ETurn power OFF Check Regular chargingMemory mode VFO mode Operation Flow ChartScan resume time p Confirmation beep p Backlighting p Power save pAuto power OFF p Ccir channels TV Frequency TableA. channels New Zealand channels Australian channelsTaiwan channels Indonesian channels China channelsItalian channels FOT channels Receiver Specifications and OptionsGeneral Options Operating periods ApproxProblem Possible Cause Solution TroubleshootingQuick Reference Quick Reference Declaration of Conformity Kamihigashi, Hirano-ku, Osaka 547-0002 Japan