SpectraLink 8002 Wireless Telephones Configuration and Administration (SIP)
Message | Description |
| Action |
|
|
|
|
|
DO NOT POWER | The handset is in a critical section |
| None. Do not remove the Battery Pack or | |||||
OFF | of the software update. |
| attempt to power off the phone while this is | |||||
|
|
| displayed. Doing so may render the | |||||
|
|
| handset inoperable. |
|
|
| ||
Duplicate IP | The handset has detected another |
| If using DHCP, check that the DHCP | |||||
| device with its same IP address. |
| server is properly configured to avoid | |||||
|
|
| duplicate addresses. |
|
|
| ||
|
|
| If using Static IP, check that the handset | |||||
|
|
| was assigned a unique address. |
|
| |||
Erase Failed | Download process failed to erase |
| Operation will retry but may eventually | |||||
| the memory in the handset. |
| report the error "int. error: 0F" Power cycle | |||||
|
|
| the handset. |
|
|
|
| |
Erasing Memory | Handset has determined that a |
| None. When the progress bar fills the | |||||
| download should occur and is |
| display line the erase operation is | |||||
| erasing the current software from |
| complete. |
|
|
|
|
|
| memory. |
| Do not remove the Battery Pack or attempt | |||||
|
|
| ||||||
|
|
| to turn the handset off during this | |||||
|
|
| operation. |
|
|
|
|
|
Files Too Big | Handset software download files |
| Download new software per Software | |||||
| are incorrect or corrupted. |
| Maintenance. |
|
|
|
| |
Flash Config Error | Handset internal configuration is |
| Perform "Restore Defaults" operation via | |||||
| corrupt. |
| administrator menus (or | |||||
|
|
| Configuration Cradle). |
|
|
| ||
Initializing … | The handset is performing power- |
| None. This is informational only. |
|
| |||
| on initialization. |
|
|
|
|
|
|
|
Internal Err. # # | The handset has detected a fault |
| Record the error code so it can be | |||||
| from which it cannot recover. |
| reported. |
|
|
|
|
|
|
|
| Turn the | handset off | then | on | again. | |
|
|
| If error persists, try registering a different | |||||
|
|
| handset | to | this | telephone | port. | |
|
|
| If error still persists, contact Polycom | |||||
|
|
| Technical Support and report the error. | |||||
Must Upgrade SW! | Handset software is incompatible |
| Download new software from the | |||||
| with hardware. |
| SpectraLink | website | per | Software | ||
|
|
| Maintenance. |
|
|
|
| |
No DHCP Server | Handset is unable to contact the |
| Check that your DHCP server is | |||||
| DHCP server. |
| operational and connected to WLAN or use | |||||
|
|
| Static IP configuration in the handset. | |||||
No ESSID | Attempted to run Site Survey |
| Statically configure an ESSID in the Admin | |||||
| application without an ESSID set. |
| menu. |
|
|
|
|
|
No Func Code | Handset software is incorrect or |
| Reconfigure the handset to gain access to | |||||
| corrupted. |
| the WLAN and download new handset | |||||
|
|
| software. |
|
|
|
|
|
92 | PN: |
VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299