MIN SPD

 

450

210~3900

P1

MAX SPD

 

2000

2000~3900

P2

No function

 

 

 

P3

No function

 

 

 

P4

ELV ZERO

 

30

1~255

P5

ELV MAX

 

245

1~255

P6

No function

 

 

 

P7

MAX TIME

 

99

5~99 min(Km/Mile

 

 

 

 

the same)

P8

WEIGHT

 

150LB(Mile)

35~400LB(Mile)

 

 

 

68kg (Km)

35~400kg(Km)

P9

OP HOURS (hr)

 

0

0~9999

P10

OP DIST

 

0

0~9999

 

(Mile/km)

 

 

 

Remarks:

1.If you want to the clean accumulate time and distance, please enter engineering mode select “ENG1” enter, please enter P9 (Accumulate Time) or P10 (Accumulate Distance) hold “ELEVATION DOWN and SPEED UP” for 3~5 sec.

Error code definition

 

 

 

Error

Definition

E2

Incline motor problem

3-10

Image 23
Contents Page Table of Contents Section Preventive Maintenance Schedule Drive Belt Running BeltProcedure Deck RE-WAXING ProcedureClean the Grooves Procedure Lubricating the AIR Shock Wiring Diagram Instruction T9700TM51D/E MCB Wiringfor 110V T9300 MCB Wiringfor 110V T9200/T9250 MCB Wiringfor 110V Console Engineering Mode Guide T9700TM51D/E Treadmills for Software Ver KEY Behale Function Remarks T9600HRTCOMFORT/T9600HRT/T9500HRT/T9450HRT Select SOU=SOURCES Parameter SCO=SCOPE Parameter 10MIL Remarks T9200/T9250 Treadmills for Software Ver. S706 Sources MCB LED Instructions MCB LED Indication MCB MCB LED Indication PWM MCB LED Chart MCB LED-AIDED Troubleshooting Chart Troubleshootings Possible causes No display on consoleRunning speed is not stable All or some of the keys on console do not work Treadmill starts to run by itselfFix Noises generated under motor coverTreadmill will not start Incline function does not work Heart-Rate-Control function does not work T9700 TM51D/E Error code definition Error Messages on the ConsoleTroubleshootings T9200/T9250 Error code definition Software Upgrade Procedure Vision Series Treadmill Software Upgrade SOP Steps