Vision Fitness T9450, T9600, T9500, T9700, T9300, T9200 Heart-Rate-Control function does not work

Page 37

Heart-Rate-Control function does not work

Possible causes:

1.Transmitter does not contact with user's chest very well.

2.Transmitter(Polar-belt) is at low battery status.

3.Transmitter(Polar-belt) is damaged.

4.Heart-rate-control board is damaged.

5.PCB is damaged.

Fix:

1.Center the transmitter on your chest below the pectoral muscle(breast) as shown, then check again.

2.Remove the battery cover of the transmitter. Replace a new battery and check again.

￿Actually, as moisture may activate the transmitter, please dry transmitter after use.

3.OR Transmitter is damaged. Replace the Transmitter.

4.OR Heart-rate-control board is damaged. Replace the HR-control board.

5.OR PCB is damaged. Replace the PCB.

5-7

Image 37
Contents Page Table of Contents Section Preventive Maintenance Schedule Drive Belt Running BeltProcedure Deck RE-WAXING ProcedureClean the Grooves Procedure Lubricating the AIR Shock Wiring Diagram Instruction T9700TM51D/E MCB Wiringfor 110V T9300 MCB Wiringfor 110V T9200/T9250 MCB Wiringfor 110V Console Engineering Mode Guide T9700TM51D/E Treadmills for Software Ver KEY Behale Function Remarks T9600HRTCOMFORT/T9600HRT/T9500HRT/T9450HRT Select SOU=SOURCES Parameter SCO=SCOPE Parameter 10MIL Remarks T9200/T9250 Treadmills for Software Ver. S706 Sources MCB LED Instructions MCB LED Indication MCB MCB LED Indication PWM MCB LED Chart MCB LED-AIDED Troubleshooting Chart Troubleshootings Possible causes No display on consoleRunning speed is not stable All or some of the keys on console do not work Treadmill starts to run by itselfFix Noises generated under motor coverTreadmill will not start Incline function does not work Heart-Rate-Control function does not work T9700 TM51D/E Error code definition Error Messages on the ConsoleTroubleshootings T9200/T9250 Error code definition Software Upgrade Procedure Vision Series Treadmill Software Upgrade SOP Steps