Vision Fitness T9200, T9600, T9500, T9450, T9700, T9300, T9350 manual Mcb

Page 26

MCB LED Indication

Note:

over 26 Amps when lit

Note:

a control command from the PCB to the

MCB

MTR Light- When lit, indicates the High Power Direct Current supply for the motor

(B+) is online. This light will remain lit for a period of time after power has been removed from the MCB. While the MTR light remains lit, anyone handling the MCB should use caution since there is still a hazardous potential present. When the MTR light is off, B+ is not present and the motor controller will not operate. If the MTR and I-limit lights are off, verify motor connections and proper motor operation. If the MTR light is off and the I-limit light is on, the MCB shut off due to an extended current limit condition. In this case, resetting the PCB or cycling power will eliminate the problem. However, the treadmill should be thoroughly examined for wear or damaged components which might have lead to the extended current limit condition. If this problem persists, return the board to JMI.

4- limit Light- When lit, indicates the current to the motor has reached the peak

current trip point of 26 Amps. The MCB will limit the current when the current limit point has been reached. If the current limit continues for roughly 5 seconds, the MCB shuts down and the I-Limit light will remain on. To reset the I-Limit, turn the treadmill off at the power switch wait about 30 seconds then turn the power back on. PWM Light- Indicates the control PWM

from the PCB is present. It will blink at the control frequency used by the PCB when the PCB commands speed. If the control signal should exceed 95 percent duty cycle, the PWM light shuts off and sets the MCB to a safe shutdown mode. In the event this should occur, the power to the treadmill should be removed, the cabling checked for shorts and the PCB replaced. If this problem persists, replace the MCB.

4-2

Image 26
Contents Page Table of Contents Section Preventive Maintenance Schedule Running Belt Drive BeltDeck RE-WAXING Procedure ProcedureClean the Grooves Procedure Lubricating the AIR Shock Wiring Diagram Instruction T9700TM51D/E MCB Wiringfor 110V T9300 MCB Wiringfor 110V T9200/T9250 MCB Wiringfor 110V Console Engineering Mode Guide T9700TM51D/E Treadmills for Software Ver KEY Behale Function Remarks T9600HRTCOMFORT/T9600HRT/T9500HRT/T9450HRT Select SOU=SOURCES Parameter SCO=SCOPE Parameter 10MIL Remarks T9200/T9250 Treadmills for Software Ver. S706 Sources MCB LED Instructions MCB LED Indication MCB MCB LED Indication PWM MCB LED Chart MCB LED-AIDED Troubleshooting Chart Troubleshootings No display on console Possible causesRunning speed is not stable Treadmill starts to run by itself All or some of the keys on console do not workNoises generated under motor cover FixTreadmill will not start Incline function does not work Heart-Rate-Control function does not work Error Messages on the Console T9700 TM51D/E Error code definitionTroubleshootings T9200/T9250 Error code definition Software Upgrade Procedure Vision Series Treadmill Software Upgrade SOP Steps