MCB LED-AIDED TROUBLESHOOTING CHART
NO. | PROBLEM/RESULT | CORRECTIVE ACTION | ||
1 | No operation of | MCB or PCB | Verify connections, power switch, circuit | |
breaker and fuse | ||||
|
|
| ||
|
|
|
| |
2 | No operation of | MCB or PCB | Check fuse F1 | |
|
|
| ||
3 | PCB will not power up | Replace MCB | ||
|
|
|
| |
4 | PCB will power up but the MCB | Verify adequate line voltage. If line voltage is | ||
adequate, MCB is damaged and needs to be | ||||
will not operate |
| |||
|
|
| returned to manufacturer. | |
|
|
| Verify connections to motor and the motor | |
|
|
| itself. If the motor and its connections are | |
|
|
| good, the MCB should be replace. Return | |
|
|
| MCB to manufacture with information on | |
5 |
|
| location. Power level, how it was used when | |
Will not operate the motor | failure occurred etc. | |||
|
|
| The motor can be verified by disconnection | |
|
|
| the motor; connecting a | |
|
|
| VCD) to the motor leads; and spinning the | |
|
|
| tread and observing a voltage. If no voltage, | |
|
|
| Bad motor. | |
|
|
| A | |
6 |
|
| Resets console or cycle power to correct. | |
Will not operate the motor | Check treadmill for excessive wear or | |||
|
|
| mechanical defects. If problem persists, return | |
|
|
| MCB. | |
|
|
| The MCB is experiencing a discontinuous over | |
7 |
|
| current events. Check for mechanical wear | |
MCB in current limit mode | and/or defective motor. If on mechanical wear | |||
|
|
| and motor good, replace MCB and return | |
|
|
| defective MCB to manufacturer. | |
8 |
|
| Check and verify the J2 and J3 cables are | |
Will not operate the motor | good, replace the PCB. If the problem | |||
|
|
| persists, replace the MCB. | |
|
|
|
| |
9 | Incline does not move | Verify connections to the J3 & incline motor. If | ||
the connections look good, check F2. | ||||
|
|
| ||
10 | Incline does not move | Verify connections to the J3 & incline motor. If | ||
the connections look good, check F2. | ||||
|
|
|