Cateye EC-C400 instruction manual Replace the battery, Replace the electrode belt

Page 47

Maintenance of the chest-belt heart rate sensor

Warning

After removing the battery from the sensor, dispose of it properly. Be sure to keep it out of the reach of small children. If through some accident it is swallowed, contact a physician immediately.

Replace the battery.

Battery life: approx. 2 years (if used for 1 hour per day)

* The battery life shown in this manual is not definitive and it var- ies depending on the use environment.

Caution: • The chest-belt heart rate sensor continues to consume battery while being attached to your body. When you are not measuring heart rate, remove it from your chest to save the battery life.

• The battery cover seal is critical for maintaining its watertight capacity. Check the battery cover for proper fit and positioning closing.

When the factory loaded battery has worn out, replace it with a new one according to the following instruction:

1.Remove the battery cover on the back of the transmitter with a coin.

2.Remove the battery and insert a new lithium battery (CR2032). Insert as shown in the picture, so that the + side is visible.

3.Close the battery cover tightly.

Replace the electrode belt.

The electrode belt will deteriorate after a long time of use. If there are cracks in the outer surface, or if measurement errors occur, follow the procedure below to change the electrode belt.

1.Loosen the 4 screws at the back of the transmitter.

2.Remove the spacers. Separate the transmitter from the electrode belt.

3.Wipe any dirt off of the two conducting parts of the transmitter, then insert it into a new electrode belt.

Caution: If there is dirt on the conducting parts, the heart rate sensor fail to detect the heart rate.

4.Fit the spacers on the right and left sides of the transmitter, and securely tighten the 4 screws.

Reference: When replacing the electrode belt, also check the transmitter’s battery life.

Battery cover

Lithium battery (CR2032)

Chest-belt heart rate sensor

Screws

Spacers

Spacers

Electrode belt

Transmitter

Conducting

part

Conducting part

Maintenance of the chest-belt heart rate sensor

For daily maintenance of the sensor:

If the chest-belt heart rate sensor is dirty, wash with water, or wipe with a diluted neutral detergent and a soft cloth. Then wipe it dry. Do not use organic solvents such as benzene and alcohol, which will damage the surface.

The attachment belt will become particularly soaked with sweat. This can be unhygienic if left as is. Clean the belt with a neutral detergent.

47

Image 47
Contents UPRIGHTEC-C4OOBIKE Contents HOW to USE this ManualIntroduction Main body Control unit Part NamesLCD Start Guide Starting with Assembly Mount the saddle Attach the front legAttach the rear leg Mount the handlebar postAttach the pedals Install the control unitAdjust the handlebar angle 2HOW to Adjust Each PartAdjust the saddle height Adjust the handlebar heightAdjust the saddle angle Use pulse earlobe sensor during exercise Adapting the Pulse SensorConnect the pulse sensor Handling of sensor cableCheck the screen display Turn on power and attach earlobe sensorTrying OUT the EC-C400FOR the First Time Insert the start card the red card providedLCD Press the Start button to startFinish your training Bring up the calories display by pressing Mode buttonHill training training by cycling up mountains 6 Kinds of ProgramsFitness Test physical fitness test HR control training training at a constant pulse rateQuick start training at any desired pedal resistance Interval training exercise + relief periodsSelect a training program Using the EC-C400WITHOUT a Data CardTurn on the power supply Input training conditions Finish your exercise Start your exerciseCheck your exercise record by scrolling the screen Operation Guide Page Training goals 1TRAINING GoalsTarget Pulse Rate Maximum Heart RateDifference between heart rate and pulse rate Pulse LimitHill training 2YOUR Strength Level and Training IndexHR control training Constant wattage control trainingQuick start training Interval trainingStart the program 3FITNESS TestSelect the Fitness test program Input the conditionsEnd the program Test result display and cool downFinish the Fitness test Maximum Physical Work Capacity PWC max 4FITNESS TestPhysical Fitness Level PFL Maximum Oxygen Uptake MOUMale≥ Test ProtocolStart the warm-up 5HR Control TrainingSelect the HR control training program Finish your exercise Continue the training, maintaining the target pulseSelect the Constant wattage control training program 6CONSTANT Wattage Control TrainingIbly, and the pedal resistance drops to the minimum Continue the training, maintaining the wattageStart the training 7HILL TrainingSelect the Hill training program Input training conditionsContinue the training Select the Interval training program 8INTERVAL TrainingContinue the training by repeating exercise and rest Select the Quick start program 9QUICK StartCool-down display or the end display Specify exercise time 10HOW to Make a Data CardSpecify program Specify ageSample data cards Specify training targetReference Guide Page Before putting on the chest-belt heart rate sensor Use the wireless chest-belt heart rate sensorCHEST-BELT Heart Rate Sensor Function of the chest-belt heart rate sensorReplace the electrode belt Replace the batteryChange the units of resistance of pedaling Change the units of weightOther Useful Functions Troubleshooting TroubleshootingAdditional Parts Daily Maintenance Repair Service WARRANTY/ADDITIONAL PartsAbout the repair service warranty Accessories/Consumable PartsProduct Specifications 066660051 E