MAINTENANCE AND TROUBLESHOOTING

Inspect and tighten all parts of the exercise bike regu- larly. Replace any worn parts immediately.

To clean the exercise bike, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight.

CONSOLE TROUBLESHOOTING

If the console display becomes dim, replace all the batteries at the same time. See assembly step 6 on page 8 for replacement instructions.

If the console does not display your heart rate when you use the handgrip pulse sensor, see step 5 on page 15.

HOW TO ADJUST THE REED SWITCH

If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, you must first remove the left pedal, the left disc cover, and the left pedal disc (see the instructions below).

Using an adjustable wrench, turn the left pedal clock-

wise and remove it.

 

 

 

Next, rotate the

 

 

 

Left Crank Arm

 

 

 

(20) to a vertical

 

 

 

position with the

 

 

 

end of the Left

 

 

 

Crank Arm point-

20

 

18

ing downward.

 

Using a flat

 

Tab

Tab

screwdriver,

 

release the tabs

 

 

 

on each point of

 

 

 

the left Disc

 

 

 

Cover (18). Carefully work the left Disc Cover over the

Left Crank Arm (20) and remove the left Disc Cover.

Next, rotate the Left

 

 

Crank Arm (20) to a

20

 

vertical position with

 

the end of the Left

 

 

Crank Arm pointing

 

 

upward. Rotate the

 

11

left Pedal Disc (17)

17

clockwise to release

 

it from the Left Shield

 

 

(11). Then, work the

 

 

left Pedal Disc upward and remove it from the Left

Crank Arm (20).

 

 

Locate the Reed Switch (57). Loosen, but do not remove, the two M4 x 12.7mm Flange Screws (63).

55

57

20

 

63

 

Next, rotate the Left Crank Arm (20) until a Magnet (55) is aligned with the Reed Switch (57). Slide the Reed Switch slightly toward or away from the Magnet. Then, retighten the M4 x 12.7mm Flange Screws (63). Rotate the Left Crank Arm (20) for a moment. Repeat these actions until the console displays correct feed- back.

When the reed switch is correctly adjusted, reattach the left pedal disc, the left disc cover, and the left pedal.

19

Image 19
Contents Model No. PFEVEX74010.0 Serial No QUESTIONS?Table of Contents Important Precautions Before YOU Begin Wrench A rubber mallet AssemblyPage Page Important If the Console has been Avoid pinching Extension WireAvoid pinching Wires Adjustment Knob is engaged in one of the adjustment holesStrap HOW to Adjust the Pedal Straps HOW to USE the Exercise BikeHOW to Adjust the Height of the Seat HOW to Adjust the Horizontal PositionPage Features of the Console Console DiagramFollow your progress with the display HOW to USE the Manual ModeSelect the manual mode Change the resistance of the pedals as desiredAvoid moving your hands or gripping the con Measure your heart rate if desiredTacts tightly Select a preset workout HOW to USE a Preset WorkoutBegin pedaling to start the workout Insert an iFit card and select a workout HOW to USE AN Ifit WorkoutWhen you are finished exercising, remove the iFit card HOW to USE the Sound SystemSelect a backlight option if desired HOW to Change the Console SettingsEnter the display settings mode Exit the display settings modeConsole Troubleshooting Maintenance and TroubleshootingHOW to Adjust the Reed Switch HOW to Adjust the Drive Belt Exercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesQty Description R0910AExploded DRAWING-Model No. PFEVEX74010.0 Recycling Information Ordering Replacement Parts