If the battery symbol is displayed in the Surface mode or if the display is faded or weak, the battery may be too low to operate the dive computer and battery replacement is recommended.

NOTE! For safety reasons the backlight cannot be activated when the low battery warning is indicated by the battery symbol.

3.1.2.2. Wireless Transmitter Battery Indicator

The pressure transmitter sends out a lowbat (LOBT) warning when its battery voltage is getting low. This is shown intermittently instead of the pressure reading (see chapter 2.4.3, Fig 2.6). When you get this warning the pressure transmitter battery needs to be replaced.

3.1.3. Dive Planning [PLAN]

To enter Planning Mode, press the PLAN button at any time during Sur- face Mode. After showing the text “PLAN” (Fig. 3.6.), the display will show the no-decompression limit for the depth of 9 m [30 ft]. By pressing the down arrow (t) (TIME) button, the dive computer will calculate and show the next deeper no-decompression limits in 3 m [10 ft] increments ending at 45 m [150 ft]. By pressing the up arrow (s) (PLAN) button, the next shallower depth will be shown again.

The Planning Mode is canceled by pressing the SMART (QUIT) button.

NOTE! The Planning mode is disabled in Gauge mode and in Error mode (see section 3.9. ”Error Conditions”). The planning mode calculates no dec times for MIX1 only. If additional mixes are enabled in the Nitrox mode they do not affect the calculations in PLAN mode.

Higher Altitude and conservative Personal Adjustment Modes will shorten the no-decompression time limits. These limits at different Altitude and Personal Adjustment Mode selections are shown in Table 6.1 and 6.2 in section 6.1. ”Operating Principles”.

The Planning mode also accounts for the following information from pre- vious dives:

any calculated residual nitrogen

all dive history for the past four days

oxygen toxicity (Nitrox mode)

The no-decompression times given for different depths will therefore be shorter than before your first “fresh” dive.

DIVE NUMBERING SHOWN DURING DIVE PLANNING

Dives belong to the same repetitive dive series, if the instrument was still counting down the no-fly time at the beginning of the dive.

20

Image 22
Contents Suunto Vytec DS Guide Reference Quick Definition of WARNINGS, Cautions and Notes COPYRIGHT, Trademark and Patent NoticePrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Introduction Suunto RGBM/ Deep Stop AlgorithmSafety Precautions Emergency AscentsNitrox Getting AcquaintedDive Computer Limitations FunctionsMaking the Vytec personal Push ButtonsPress the Smart Mode button Water ContactsWireless Cylinder Pressure Transmission Installing the TransmitterPairing and Code Selection Transmission Data Fail Pressure Transmission Related DisplaysSetc LobtBefore Diving Diving with the VytecActivation and Prechecks Battery Indication Battery Power IndicatorBattery Power Indicator Lowbat +Dive Planning Plan Wireless Transmitter Battery IndicatorDive Numbering Shown During Dive Planning Safety Stops User Definable Functions and AlarmsRecommended Safety Stop Mandatory Safety Stop Diving display. Pres- ent depth is 19.3 mDeep Stops Diving in AIR ModeBasic Dive Data Bookmark Cylinder Pressure DataConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorSafety Stops and Deep Stops Decompression divesCEILING, Ceiling ZONE, Floor Decompression Range Display Above the Floor Display below the FloorDisplay AT the Ceiling Zone Diving in Nitrox Mode 3.4.1. Before Diving Display Above the CeilingDefault Nitrox Settings Oxygen Displays22. Diving in Nitrox mode. The O2% is set to 32% OLF Oxygen Limit FractionGas Change, Multiple Breathing Gas Mixes Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Dive Numbering Separated by a colon, tellingFlying After Diving Audible and Visual Alarms Three double beeps occur, whenOxygen Alarms in Nitrox Mode Set oxygen partial pressure limit is exceeded. The maximumPersonal Adjustment High Altitude Dives and Personal AdjustmentAltitude Adjustment Altitude Adjustment RangesPersonal Adjustment Ranges Rgbm Model Settings Error ConditionsOmitted Decompression Menu Based Modes USE of the Menu Based FunctionsExit / Quit List of the Menu Based ModesMemories and Data Transfer 1 Memory Logbook and Dive Profile Memory 1 LogbookI, main display Fig III Fig Dive History Memory 2 History Dive Profile Memory ProfData Transfer and PC-Interface 3 TR-PC Simulation Mode 2 Simul Dive Simulator 1 SimdiveDive Planning Simulator 2 Simplan SET Modes 3 SETDive Parameter Settings 1 SET Dive Maximum Depth Alarm Setting 3 MAX Dpth Dive Time Alarm Setting 2 d AlarmNitrox/Oxygen Settings 4 Nitrox Setting Time 2 SET Time Adjusting Time 1 AdJ TimeSetting Preferences 3 SET Pref Adjusting Date 2 AdJ DateAdjusting Daily Alarm 3 T Alarm Backlight Setting 1 LightProfile Sample Rate Setting 4 REC Dive Computer Units Setting 2 UnitsWireless Transmission Settings 3 HP Dive Computer Model Setting 5 ModelCare of Your Dive Computer Care and MaintenanceImportant Information Water Contacts and Push ButtonsMaintenance Water Resistance InspectionBattery Replacement 5.5.1. Computer battery Battery KITBattery Replacement Tools RequiredPage Wireless Transmitter Battery Replacement Opening of the securing ringTransmitter Battery Replacement Tools RequiredOperating Principles Technical DescriptionNO-DECOMPRESSION Limits Altitude Diving Suunto Reduced Gradient Bubble Model Rgbm Surface IntervalsOxygen Exposure Technical Specification TransmitterOther displays Battery Vytec Warranty SUUNTOSPORTS.COM System RequirementsMy Suunto CommunitiesSport Forums Getting StartedGlossary EAD EANNo DEC Time NitroxNoaa OLFRgbm PO2Surf Time Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08