Suunto VYTEC DS manual Wireless Cylinder Pressure Transmission, Installing the Transmitter

Page 15

2.4.WIRELESS CYLINDER PRESSURE TRANSMISSION

The Vytec can be used together with an optional wireless cylinder pressure transmitter that can easily be attached to the high-pres- sure port of the regulator (Fig. 2.5). By using the transmitter the diver can benefit from cylin- der pressure and remaining air time data.

In order to use the transmitter the wireless integration needs to be enabled in the Vytec’s settings. To enable or disable the wireless integration refer to chapter 4.3.3.3 Cylinder pressure settings.

2.4.1. Installing the Transmitter

Upon purchasing the Vytec, Suunto strongly recommends you have your dealer attach the transmitter to the first stage of your regulator.

If you decide to attach it yourself, follow the steps outlined below:

Remove the high pressure (HP) port plug on the first stage of your regulator using an appropriate tool.

Thread the high pressure transmitter of the Vy- tec into the HP port of your regulator with your fingers. DO NOT OVERTIGHTEN! Maximum torque 6 Nm (4.4 ftlbs or 53 inlbs). Sealing is based on a static o-ring, not force!

Attach the regulator to the scuba cylinder. Slowly open the valve. Check for leaks by submerging the regulator first stage in water. If leaks are detected, check the condition of the o-ring and sealing surfaces.

Fig. 2.4. Active water contacts are indicated by the text AC.

Fig. 2.5. Vytec’s optional wireless pressure trans- mitter.

13

Image 15
Contents Suunto Vytec DS Guide Reference Quick COPYRIGHT, Trademark and Patent Notice Definition of WARNINGS, Cautions and NotesPrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Suunto RGBM/ Deep Stop Algorithm IntroductionEmergency Ascents Safety PrecautionsFunctions Getting AcquaintedDive Computer Limitations NitroxPush Buttons Making the Vytec personalWater Contacts Press the Smart Mode buttonInstalling the Transmitter Wireless Cylinder Pressure TransmissionPairing and Code Selection Transmission Data Lobt Pressure Transmission Related DisplaysSetc FailDiving with the Vytec Before DivingActivation and Prechecks Battery Power Indicator Battery IndicationLowbat + Battery Power IndicatorWireless Transmitter Battery Indicator Dive Planning PlanDive Numbering Shown During Dive Planning User Definable Functions and Alarms Safety StopsRecommended Safety Stop Diving display. Pres- ent depth is 19.3 m Mandatory Safety StopDiving in AIR Mode Deep StopsBasic Dive Data Cylinder Pressure Data BookmarkConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorDecompression dives Safety Stops and Deep StopsCEILING, Ceiling ZONE, Floor Decompression Range Display below the Floor Display Above the FloorDisplay AT the Ceiling Zone Display Above the Ceiling Diving in Nitrox Mode 3.4.1. Before DivingOxygen Displays Default Nitrox Settings22. Diving in Nitrox mode. The O2% is set to 32% Oxygen Limit Fraction OLFGas Change, Multiple Breathing Gas Mixes Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Separated by a colon, telling Dive NumberingFlying After Diving Three double beeps occur, when Audible and Visual AlarmsSet oxygen partial pressure limit is exceeded. The maximum Oxygen Alarms in Nitrox ModeAltitude Adjustment Ranges High Altitude Dives and Personal AdjustmentAltitude Adjustment Personal AdjustmentPersonal Adjustment Ranges Error Conditions Rgbm Model SettingsOmitted Decompression USE of the Menu Based Functions Menu Based ModesList of the Menu Based Modes Exit / QuitLogbook and Dive Profile Memory 1 Logbook Memories and Data Transfer 1 MemoryI, main display Fig III Fig Dive Profile Memory Prof Dive History Memory 2 HistoryData Transfer and PC-Interface 3 TR-PC Dive Simulator 1 Simdive Simulation Mode 2 SimulSET Modes 3 SET Dive Planning Simulator 2 SimplanDive Parameter Settings 1 SET Dive Dive Time Alarm Setting 2 d Alarm Maximum Depth Alarm Setting 3 MAX DpthNitrox/Oxygen Settings 4 Nitrox Adjusting Time 1 AdJ Time Setting Time 2 SET TimeBacklight Setting 1 Light Adjusting Date 2 AdJ DateAdjusting Daily Alarm 3 T Alarm Setting Preferences 3 SET PrefDive Computer Model Setting 5 Model Dive Computer Units Setting 2 UnitsWireless Transmission Settings 3 HP Profile Sample Rate Setting 4 RECWater Contacts and Push Buttons Care and MaintenanceImportant Information Care of Your Dive ComputerWater Resistance Inspection MaintenanceBattery KIT Battery Replacement 5.5.1. Computer batteryTools Required Battery ReplacementPage Opening of the securing ring Wireless Transmitter Battery ReplacementTools Required Transmitter Battery ReplacementTechnical Description Operating PrinciplesNO-DECOMPRESSION Limits Altitude Diving Surface Intervals Suunto Reduced Gradient Bubble Model RgbmOxygen Exposure Transmitter Technical SpecificationOther displays Battery Vytec Warranty System Requirements SUUNTOSPORTS.COMCommunities My SuuntoGetting Started Sport ForumsGlossary EAN EADOLF NitroxNoaa No DEC TimePO2 RgbmSurf Time Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08