Suunto VYTEC DS manual Diving in Nitrox mode. The O2% is set to 32%

Page 34

m

MAX

O2%

NO DEC TIME

OLF

bar

DIVE TIME

Fig. 3.22. Diving in Nitrox mode. The O2% is set to 32%.

 

m

 

MAX

AIR TIME

NO DEC TIME

OLF

 

bar

DIVE TIME

Fig. 3.23. Diving in Nitrox mode. After air time is less than 30 minutes O2% is substituted by Air Time display.

m

PO2

O2%

NO DEC TIME

OLF

bar

DIVE TIME

Fig. 3.24. Oxygen partial pressure and OLF displays. There is an audible alarm as oxygen partial pressure is greater than 1.4 bar or set value, and/or the OLF has reached 80% limit.

label NITROX, is shown after activation. In Dive Planning mode the Nitrox display shows (Fig. 3.21.):

the oxygen percentage, labeled with

O2%, is shown in the left side of the center window

the set oxygen partial pressure limit,

labeled with PO2, is shown in the upper right display

the maximum allowed depth based on the set oxygen percentage and partial pressure limit

the current oxygen toxicity exposure shown with an Oxygen Limit Fraction (OLF) bar graph along the left side of the display (instead of the CBT).

In the Dive modes, the oxygen percentage la- beled with O2% and the current oxygen toxicity exposure shown with an Oxygen Limit Frac- tion (OLF) bar graph are shown (Fig. 3.22. and Fig. 3.23.). If the wireless transmission is enabled the O2% is shown until the remain- ing air time is less than 30 minutes. After this, the remaining air time is displayed in its place. During a dive, the oxygen partial pressure, la- beled with PO2, is also shown instead of the maximum depth in the upper right display, if the partial pressure is greater than 1.4 bar or the set value (Fig. 3.24.).

By pressing the TIME button during a nitrox dive, the alternative display appears, which includes (Fig. 3.25.):

current time

temperature

Consumed Bottom Time

maximum depth (during decom- pression stop dive).

remaining air time when remaining air time is over 30min

oxygen percentage when remaining air time less than 30 min

32

Image 34
Contents Suunto Vytec DS Guide Reference Quick Definition of WARNINGS, Cautions and Notes COPYRIGHT, Trademark and Patent NoticePrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Introduction Suunto RGBM/ Deep Stop AlgorithmSafety Precautions Emergency AscentsNitrox Getting AcquaintedDive Computer Limitations FunctionsMaking the Vytec personal Push ButtonsPress the Smart Mode button Water ContactsWireless Cylinder Pressure Transmission Installing the TransmitterPairing and Code Selection Transmission Data Fail Pressure Transmission Related DisplaysSetc LobtBefore Diving Diving with the VytecActivation and Prechecks Battery Indication Battery Power IndicatorBattery Power Indicator Lowbat +Dive Planning Plan Wireless Transmitter Battery IndicatorDive Numbering Shown During Dive Planning Safety Stops User Definable Functions and AlarmsRecommended Safety Stop Mandatory Safety Stop Diving display. Pres- ent depth is 19.3 mDeep Stops Diving in AIR ModeBasic Dive Data Bookmark Cylinder Pressure DataConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorSafety Stops and Deep Stops Decompression divesCEILING, Ceiling ZONE, Floor Decompression Range Display Above the Floor Display below the FloorDisplay AT the Ceiling Zone Diving in Nitrox Mode 3.4.1. Before Diving Display Above the CeilingDefault Nitrox Settings Oxygen Displays22. Diving in Nitrox mode. The O2% is set to 32% OLF Oxygen Limit FractionGas Change, Multiple Breathing Gas Mixes Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Dive Numbering Separated by a colon, tellingFlying After Diving Audible and Visual Alarms Three double beeps occur, whenOxygen Alarms in Nitrox Mode Set oxygen partial pressure limit is exceeded. The maximumPersonal Adjustment High Altitude Dives and Personal AdjustmentAltitude Adjustment Altitude Adjustment RangesPersonal Adjustment Ranges Rgbm Model Settings Error ConditionsOmitted Decompression Menu Based Modes USE of the Menu Based FunctionsExit / Quit List of the Menu Based ModesMemories and Data Transfer 1 Memory Logbook and Dive Profile Memory 1 LogbookI, main display Fig III Fig Dive History Memory 2 History Dive Profile Memory ProfData Transfer and PC-Interface 3 TR-PC Simulation Mode 2 Simul Dive Simulator 1 SimdiveDive Planning Simulator 2 Simplan SET Modes 3 SETDive Parameter Settings 1 SET Dive Maximum Depth Alarm Setting 3 MAX Dpth Dive Time Alarm Setting 2 d AlarmNitrox/Oxygen Settings 4 Nitrox Setting Time 2 SET Time Adjusting Time 1 AdJ TimeSetting Preferences 3 SET Pref Adjusting Date 2 AdJ DateAdjusting Daily Alarm 3 T Alarm Backlight Setting 1 LightProfile Sample Rate Setting 4 REC Dive Computer Units Setting 2 UnitsWireless Transmission Settings 3 HP Dive Computer Model Setting 5 ModelCare of Your Dive Computer Care and MaintenanceImportant Information Water Contacts and Push ButtonsMaintenance Water Resistance InspectionBattery Replacement 5.5.1. Computer battery Battery KITBattery Replacement Tools RequiredPage Wireless Transmitter Battery Replacement Opening of the securing ringTransmitter Battery Replacement Tools RequiredOperating Principles Technical DescriptionNO-DECOMPRESSION Limits Altitude Diving Suunto Reduced Gradient Bubble Model Rgbm Surface IntervalsOxygen Exposure Technical Specification TransmitterOther displays Battery Vytec Warranty SUUNTOSPORTS.COM System RequirementsMy Suunto CommunitiesSport Forums Getting StartedGlossary EAD EANNo DEC Time NitroxNoaa OLFRgbm PO2Surf Time Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08