Suunto VYTEC DS manual User Definable Functions and Alarms, Safety Stops, Recommended Safety Stop

Page 23

The surface interval must be at least 5 minutes for a dive to be considered a repetitive dive. Otherwise, it is considered a continuation of the same dive. The dive number will not change and the dive time will continue, where it left off (see also section 3.6.2. “Dive Numbering”).

3.1.4. User Definable Functions and Alarms

This Vytec has several User Definable Functions and depth and time related alarms that you can set according to your personal preference.

The dive computer model, unit of measurement and backlight prefer- ences can be set in the MODE- SET- SET PREF submode. The dive time and the depth alarms can be set in the MODE- SET- SET DIVE submode and the alarm clock can be set in the MODE- SET- SET TIME submode. Setting of the user definable functions and alarms are explained in detail in section 4.3. “Set Modes”.

3.2. SAFETY STOPS

Safety stops are widely considered “good diving practice” and are an integral part of most dive tables. Reasons to perform a safety stop include a reduction in sub clinical DCI, microbubble reduction, ascent control, and orientation before surfacing.

The Vytec displays two different types of safety stops: Recommended Safety Stop and Mandatory Safety Stop.

The Safety Stops are indicated by:

-STOP label, when in the depth range 3 m – 6 m [10 ft - 20 ft] = Recommended Safety Stop Countdown

-STOP+ CEILING label, when in the depth range 3 m – 6 m [10 ft - 20 ft] = Mandatory Safety Stop Time display

-STOP label, when deeper than 6 m = Mandatory Safety Stop scheduled

3.2.1. Recommended Safety Stop

With every dive over 10 meters the instrument has a three minute count- down for the recommended safety stop, to be taken in the 3 - 6 meter [10 ft - 20 ft] range. This is shown with the STOP sign and a three-minute countdown in the center window instead of the no-decompression time (Fig. 3.11.).

The Recommended Safety Stop, as the name implies, is recommended. If it is ignored, there is no penalty applied to the following surface inter- vals and dives.

21

Image 23
Contents Suunto Vytec DS Guide Reference Quick COPYRIGHT, Trademark and Patent Notice Definition of WARNINGS, Cautions and NotesPrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Suunto RGBM/ Deep Stop Algorithm IntroductionEmergency Ascents Safety PrecautionsFunctions Getting AcquaintedDive Computer Limitations NitroxPush Buttons Making the Vytec personalWater Contacts Press the Smart Mode buttonInstalling the Transmitter Wireless Cylinder Pressure TransmissionPairing and Code Selection Transmission Data Lobt Pressure Transmission Related DisplaysSetc FailActivation and Prechecks Diving with the VytecBefore Diving Battery Power Indicator Battery IndicationLowbat + Battery Power IndicatorDive Numbering Shown During Dive Planning Wireless Transmitter Battery IndicatorDive Planning Plan Recommended Safety Stop User Definable Functions and AlarmsSafety Stops Diving display. Pres- ent depth is 19.3 m Mandatory Safety StopBasic Dive Data Diving in AIR ModeDeep Stops Cylinder Pressure Data BookmarkConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorDecompression dives Safety Stops and Deep StopsCEILING, Ceiling ZONE, Floor Decompression Range Display AT the Ceiling Zone Display below the FloorDisplay Above the Floor Display Above the Ceiling Diving in Nitrox Mode 3.4.1. Before DivingOxygen Displays Default Nitrox Settings22. Diving in Nitrox mode. The O2% is set to 32% Gas Change, Multiple Breathing Gas Mixes Oxygen Limit FractionOLF Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Separated by a colon, telling Dive NumberingFlying After Diving Three double beeps occur, when Audible and Visual AlarmsSet oxygen partial pressure limit is exceeded. The maximum Oxygen Alarms in Nitrox ModeAltitude Adjustment Ranges High Altitude Dives and Personal AdjustmentAltitude Adjustment Personal AdjustmentPersonal Adjustment Ranges Omitted Decompression Error ConditionsRgbm Model Settings USE of the Menu Based Functions Menu Based ModesList of the Menu Based Modes Exit / QuitLogbook and Dive Profile Memory 1 Logbook Memories and Data Transfer 1 MemoryI, main display Fig III Fig Dive Profile Memory Prof Dive History Memory 2 HistoryData Transfer and PC-Interface 3 TR-PC Dive Simulator 1 Simdive Simulation Mode 2 SimulSET Modes 3 SET Dive Planning Simulator 2 SimplanDive Parameter Settings 1 SET Dive Nitrox/Oxygen Settings 4 Nitrox Dive Time Alarm Setting 2 d AlarmMaximum Depth Alarm Setting 3 MAX Dpth Adjusting Time 1 AdJ Time Setting Time 2 SET TimeBacklight Setting 1 Light Adjusting Date 2 AdJ DateAdjusting Daily Alarm 3 T Alarm Setting Preferences 3 SET PrefDive Computer Model Setting 5 Model Dive Computer Units Setting 2 UnitsWireless Transmission Settings 3 HP Profile Sample Rate Setting 4 RECWater Contacts and Push Buttons Care and MaintenanceImportant Information Care of Your Dive ComputerWater Resistance Inspection MaintenanceBattery KIT Battery Replacement 5.5.1. Computer batteryTools Required Battery ReplacementPage Opening of the securing ring Wireless Transmitter Battery ReplacementTools Required Transmitter Battery ReplacementNO-DECOMPRESSION Limits Technical DescriptionOperating Principles Altitude Diving Surface Intervals Suunto Reduced Gradient Bubble Model RgbmOxygen Exposure Transmitter Technical SpecificationOther displays Battery Vytec Warranty System Requirements SUUNTOSPORTS.COMCommunities My SuuntoGetting Started Sport ForumsGlossary EAN EADOLF NitroxNoaa No DEC TimeSurf Time PO2Rgbm Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08