Suunto VYTEC DS manual PO2, Rgbm, Surf Time

Page 80

O2%

Oxygen percentage or oxygen fraction in

 

the breathing gas. Standard air has 21%

 

oxygen.

Oxygen partial pressure

Limits the maximum depth to which the

 

used Nitrox mixture can safely be used. The

 

maximum partial pressure limit for enriched

 

air diving is 1.4 bar. The contingency partial

 

pressure limit is 1.6 bar. Dives beyond this

 

limit have the risk for immediate oxygen

 

toxicity.

PO2

Abbreviation for oxygen partial pressure.

RGBM

Abbreviation for Reduced Gradient Bubble

 

Model.

Reduced Gradient Bubble Model

Modern algorithm for tracking both dissolved and free gas in divers.

Repetitive dive

Any dive whose decompression time limits

 

are affected by residual nitrogen absorbed

 

during previous dives.

Residual nitrogen

The amount of excess nitrogen remaining in

 

a diver after one or more dives.

SURF TIME

Abbreviation for surface interval time.

Surface interval time

Elapsed time between surfacing from a dive

 

and beginning a descent for the subsequent

 

repetitive dive.

78

Image 80
Contents Suunto Vytec DS Guide Reference Quick Definition of WARNINGS, Cautions and Notes COPYRIGHT, Trademark and Patent NoticePrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Introduction Suunto RGBM/ Deep Stop AlgorithmSafety Precautions Emergency AscentsGetting Acquainted Dive Computer LimitationsNitrox FunctionsMaking the Vytec personal Push ButtonsPress the Smart Mode button Water ContactsWireless Cylinder Pressure Transmission Installing the TransmitterPairing and Code Selection Transmission Data Pressure Transmission Related Displays SetcFail LobtActivation and Prechecks Diving with the VytecBefore Diving Battery Indication Battery Power IndicatorBattery Power Indicator Lowbat +Dive Numbering Shown During Dive Planning Wireless Transmitter Battery IndicatorDive Planning Plan Recommended Safety Stop User Definable Functions and AlarmsSafety Stops Mandatory Safety Stop Diving display. Pres- ent depth is 19.3 mBasic Dive Data Diving in AIR ModeDeep Stops Bookmark Cylinder Pressure DataConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorSafety Stops and Deep Stops Decompression divesCEILING, Ceiling ZONE, Floor Decompression Range Display AT the Ceiling Zone Display below the FloorDisplay Above the Floor Diving in Nitrox Mode 3.4.1. Before Diving Display Above the CeilingDefault Nitrox Settings Oxygen Displays22. Diving in Nitrox mode. The O2% is set to 32% Gas Change, Multiple Breathing Gas Mixes Oxygen Limit FractionOLF Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Dive Numbering Separated by a colon, tellingFlying After Diving Audible and Visual Alarms Three double beeps occur, whenOxygen Alarms in Nitrox Mode Set oxygen partial pressure limit is exceeded. The maximumHigh Altitude Dives and Personal Adjustment Altitude AdjustmentPersonal Adjustment Altitude Adjustment RangesPersonal Adjustment Ranges Omitted Decompression Error ConditionsRgbm Model Settings Menu Based Modes USE of the Menu Based FunctionsExit / Quit List of the Menu Based ModesMemories and Data Transfer 1 Memory Logbook and Dive Profile Memory 1 LogbookI, main display Fig III Fig Dive History Memory 2 History Dive Profile Memory ProfData Transfer and PC-Interface 3 TR-PC Simulation Mode 2 Simul Dive Simulator 1 SimdiveDive Planning Simulator 2 Simplan SET Modes 3 SETDive Parameter Settings 1 SET Dive Nitrox/Oxygen Settings 4 Nitrox Dive Time Alarm Setting 2 d AlarmMaximum Depth Alarm Setting 3 MAX Dpth Setting Time 2 SET Time Adjusting Time 1 AdJ TimeAdjusting Date 2 AdJ Date Adjusting Daily Alarm 3 T AlarmSetting Preferences 3 SET Pref Backlight Setting 1 LightDive Computer Units Setting 2 Units Wireless Transmission Settings 3 HPProfile Sample Rate Setting 4 REC Dive Computer Model Setting 5 ModelCare and Maintenance Important InformationCare of Your Dive Computer Water Contacts and Push ButtonsMaintenance Water Resistance InspectionBattery Replacement 5.5.1. Computer battery Battery KITBattery Replacement Tools RequiredPage Wireless Transmitter Battery Replacement Opening of the securing ringTransmitter Battery Replacement Tools RequiredNO-DECOMPRESSION Limits Technical DescriptionOperating Principles Altitude Diving Suunto Reduced Gradient Bubble Model Rgbm Surface IntervalsOxygen Exposure Technical Specification TransmitterOther displays Battery Vytec Warranty SUUNTOSPORTS.COM System RequirementsMy Suunto CommunitiesSport Forums Getting StartedGlossary EAD EANNitrox NoaaNo DEC Time OLFSurf Time PO2Rgbm Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08