Suunto VYTEC DS manual Mandatory Safety Stop, Diving display. Pres- ent depth is 19.3 m

Page 24

 

 

m

 

 

MAX

 

 

NO DEC TIME

C

 

 

B

 

 

T

bar

DIVE TIME

Fig. 3.7. Dive has just begun and no air time is shown. First estimate of remaining air time will be shown after 30-60 seconds.

 

 

m

 

 

MAX

 

AIR TIME

NO DEC TIME

C

 

 

B

 

 

T

bar

DIVE TIME

Fig. 3.8. Diving display. Pres- ent depth is 19.3 m

[63 ft] and no-decompression stop time limit is 23 minutes in A0/P1 mode. Maximum depth during this dive was

19.8m [65 ft], elapsed dive time is 16 minutes.

 

 

m

 

 

MAX

 

AIR TIME

NO DEC TIME

C

 

 

B

 

 

T

bar

DIVE TIME

°C

 

TIME

3.2.2. Mandatory Safety Stop

When the ascent rate exceeds 12 meters/min [40 ft] momentarily or 10 meters/min [33ft] con- tinuously the micro-bubble build-up is predicted to be more than allowed for in the decompres- sion model. The Suunto RGBM calculation model responds to this by adding a Mandatory Safety Stop to the dive. The time of this Manda- tory Safety Stop will depend on the severity of the ascent rate excess.

The STOP sign will appear in the display and when you reach the depth zone between 6 m to 3 m [20 ft to 10] also the CEILING label, ceiling depth and the calculated Safety Stop time appear in the display. You should wait until the Mandatory Safety Stop warning disappears (Fig. 3.14.).

The Mandatory Safety Stop time always in- cludes the three minute Recommended Safety Stop time. The total length of the Mandatory Safety Stop time depends on the seriousness of the ascent rate violation.

You must not ascend shallower than 3 m [10 ft] with the Mandatory Safety Stop warning on. If you ascend above the Mandatory Safety Stop ceiling, a downward pointing arrow will appear and a continuous beeping starts (Fig. 3.15.). You should immediately descend to, or below, the Mandatory Safety Stop ceiling depth. If you correct this situation at any time during that dive, there are no affects on the decompression cal- culations for future dives.

If you continue to violate the Mandatory Safety Stop, the tissue calculation model is affected and the dive computer shortens the available no-decompression time for your next dive. In this situation, it is recommended to prolong your surface interval time before your next dive.

Fig. 3.9. Diving display. Present cylinder pressure is 210 bar [3045 psi] and remaining air time 41 minutes. Alternative display of current time and temperature is shown for 5 seconds after pressing TIME button.

22

Image 24
Contents Suunto Vytec DS Guide Reference Quick Definition of WARNINGS, Cautions and Notes COPYRIGHT, Trademark and Patent NoticePrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Introduction Suunto RGBM/ Deep Stop AlgorithmSafety Precautions Emergency AscentsGetting Acquainted Dive Computer LimitationsNitrox FunctionsMaking the Vytec personal Push ButtonsPress the Smart Mode button Water ContactsWireless Cylinder Pressure Transmission Installing the TransmitterPairing and Code Selection Transmission Data Pressure Transmission Related Displays SetcFail LobtDiving with the Vytec Before DivingActivation and Prechecks Battery Indication Battery Power Indicator Battery Power Indicator Lowbat +Wireless Transmitter Battery Indicator Dive Planning PlanDive Numbering Shown During Dive Planning User Definable Functions and Alarms Safety StopsRecommended Safety Stop Mandatory Safety Stop Diving display. Pres- ent depth is 19.3 mDiving in AIR Mode Deep StopsBasic Dive Data Bookmark Cylinder Pressure DataConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorSafety Stops and Deep Stops Decompression divesCEILING, Ceiling ZONE, Floor Decompression Range Display below the Floor Display Above the FloorDisplay AT the Ceiling Zone Diving in Nitrox Mode 3.4.1. Before Diving Display Above the CeilingDefault Nitrox Settings Oxygen Displays22. Diving in Nitrox mode. The O2% is set to 32% Oxygen Limit Fraction OLFGas Change, Multiple Breathing Gas Mixes Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Dive Numbering Separated by a colon, tellingFlying After Diving Audible and Visual Alarms Three double beeps occur, whenOxygen Alarms in Nitrox Mode Set oxygen partial pressure limit is exceeded. The maximumHigh Altitude Dives and Personal Adjustment Altitude AdjustmentPersonal Adjustment Altitude Adjustment RangesPersonal Adjustment Ranges Error Conditions Rgbm Model SettingsOmitted Decompression Menu Based Modes USE of the Menu Based FunctionsExit / Quit List of the Menu Based ModesMemories and Data Transfer 1 Memory Logbook and Dive Profile Memory 1 LogbookI, main display Fig III Fig Dive History Memory 2 History Dive Profile Memory ProfData Transfer and PC-Interface 3 TR-PC Simulation Mode 2 Simul Dive Simulator 1 SimdiveDive Planning Simulator 2 Simplan SET Modes 3 SETDive Parameter Settings 1 SET Dive Dive Time Alarm Setting 2 d Alarm Maximum Depth Alarm Setting 3 MAX DpthNitrox/Oxygen Settings 4 Nitrox Setting Time 2 SET Time Adjusting Time 1 AdJ TimeAdjusting Date 2 AdJ Date Adjusting Daily Alarm 3 T AlarmSetting Preferences 3 SET Pref Backlight Setting 1 LightDive Computer Units Setting 2 Units Wireless Transmission Settings 3 HPProfile Sample Rate Setting 4 REC Dive Computer Model Setting 5 ModelCare and Maintenance Important InformationCare of Your Dive Computer Water Contacts and Push ButtonsMaintenance Water Resistance InspectionBattery Replacement 5.5.1. Computer battery Battery KITBattery Replacement Tools RequiredPage Wireless Transmitter Battery Replacement Opening of the securing ringTransmitter Battery Replacement Tools RequiredTechnical Description Operating PrinciplesNO-DECOMPRESSION Limits Altitude Diving Suunto Reduced Gradient Bubble Model Rgbm Surface IntervalsOxygen Exposure Technical Specification TransmitterOther displays Battery Vytec Warranty SUUNTOSPORTS.COM System RequirementsMy Suunto CommunitiesSport Forums Getting StartedGlossary EAD EANNitrox NoaaNo DEC Time OLFPO2 RgbmSurf Time Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08