Suunto VYTEC DS Memories and Data Transfer 1 Memory, Logbook and Dive Profile Memory 1 Logbook

Page 47

4.1.MEMORIES AND DATA TRANSFER [1 MEMORY]

The memory options (Fig. 4.5.) for this dive computer include the combined Logbook and Dive Profile Memory (Fig. 4.6. – 4.12.), Dive History Memory (Fig. 4.13. – 4.14.) and the Data Transfer and PC-Interface functions (Fig. 4.15.).

The dive entry time and date is registered in the Logbook memory. Always check before diving that the time and date are correctly set, especially after traveling between different time zones.

QUIT

OPTIONS

Fig. 4.5. Memory options. [3 MEMORY].

4.1.1.Logbook and Dive Profile Memory [1 LOGBOOK]

This instrument has a very sophisticated high capacity Logbook and Profile Memory, with a default data recording interval of 20 seconds. Dives shorter than the recording interval are not registered. You have the possibility to set the recording interval to 10, 20, 30 or 60 sec- onds (See Setting Preferences).

To enter the Logbook Memory Mode select MODE- 1 MEMORY- 1 LOGBOOK.

For each dive there are four pages of logbook dive information. Use the scroll buttons to scroll the display between Logbook pages I, II, III and IV. The data of the most recent dive is shown first.

The logbook dives can be scrolled through displaying only the first page of each dive, or scrolling through the 4 different pages of a dive.

When at the first page of a dive use the MODE button to change the scroll sequence. When the arrow icon is next to the Mode button the scroll button will scroll through the first page only of each dive.

SELECT

Fig. 4.6. Logbook option. [1 LOGBOOK].

page 1

DIVE

SELECT

TIME

Fig. 4.7. Logbook, page I. Scroll different pages of specific dive.

45

Image 47
Contents Suunto Vytec DS Guide Reference Quick COPYRIGHT, Trademark and Patent Notice Definition of WARNINGS, Cautions and NotesPrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Suunto RGBM/ Deep Stop Algorithm IntroductionEmergency Ascents Safety PrecautionsFunctions Getting AcquaintedDive Computer Limitations NitroxPush Buttons Making the Vytec personalWater Contacts Press the Smart Mode buttonInstalling the Transmitter Wireless Cylinder Pressure TransmissionPairing and Code Selection Transmission Data Lobt Pressure Transmission Related DisplaysSetc FailActivation and Prechecks Diving with the VytecBefore Diving Battery Power Indicator Battery IndicationLowbat + Battery Power IndicatorDive Numbering Shown During Dive Planning Wireless Transmitter Battery IndicatorDive Planning Plan Recommended Safety Stop User Definable Functions and AlarmsSafety Stops Diving display. Pres- ent depth is 19.3 m Mandatory Safety StopBasic Dive Data Diving in AIR ModeDeep Stops Cylinder Pressure Data BookmarkConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorDecompression dives Safety Stops and Deep StopsCEILING, Ceiling ZONE, Floor Decompression Range Display AT the Ceiling Zone Display below the FloorDisplay Above the Floor Display Above the Ceiling Diving in Nitrox Mode 3.4.1. Before DivingOxygen Displays Default Nitrox Settings22. Diving in Nitrox mode. The O2% is set to 32% Gas Change, Multiple Breathing Gas Mixes Oxygen Limit FractionOLF Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Separated by a colon, telling Dive NumberingFlying After Diving Three double beeps occur, when Audible and Visual AlarmsSet oxygen partial pressure limit is exceeded. The maximum Oxygen Alarms in Nitrox ModeAltitude Adjustment Ranges High Altitude Dives and Personal AdjustmentAltitude Adjustment Personal AdjustmentPersonal Adjustment Ranges Omitted Decompression Error Conditions Rgbm Model Settings USE of the Menu Based Functions Menu Based ModesList of the Menu Based Modes Exit / QuitLogbook and Dive Profile Memory 1 Logbook Memories and Data Transfer 1 MemoryI, main display Fig III Fig Dive Profile Memory Prof Dive History Memory 2 HistoryData Transfer and PC-Interface 3 TR-PC Dive Simulator 1 Simdive Simulation Mode 2 SimulSET Modes 3 SET Dive Planning Simulator 2 SimplanDive Parameter Settings 1 SET Dive Nitrox/Oxygen Settings 4 Nitrox Dive Time Alarm Setting 2 d AlarmMaximum Depth Alarm Setting 3 MAX Dpth Adjusting Time 1 AdJ Time Setting Time 2 SET TimeBacklight Setting 1 Light Adjusting Date 2 AdJ DateAdjusting Daily Alarm 3 T Alarm Setting Preferences 3 SET PrefDive Computer Model Setting 5 Model Dive Computer Units Setting 2 UnitsWireless Transmission Settings 3 HP Profile Sample Rate Setting 4 RECWater Contacts and Push Buttons Care and MaintenanceImportant Information Care of Your Dive ComputerWater Resistance Inspection MaintenanceBattery KIT Battery Replacement 5.5.1. Computer batteryTools Required Battery ReplacementPage Opening of the securing ring Wireless Transmitter Battery ReplacementTools Required Transmitter Battery ReplacementNO-DECOMPRESSION Limits Technical DescriptionOperating Principles Altitude Diving Surface Intervals Suunto Reduced Gradient Bubble Model RgbmOxygen Exposure Transmitter Technical SpecificationOther displays Battery Vytec Warranty System Requirements SUUNTOSPORTS.COMCommunities My SuuntoGetting Started Sport ForumsGlossary EAN EADOLF NitroxNoaa No DEC TimeSurf Time PO2Rgbm Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08