Suunto VYTEC DS manual Personal Adjustment Ranges

Page 43

cold exposure - water temperature less than 20 °C [68 °F]

the diver is below average physical fitness level

diver fatigue

diver dehydration

previous history of DCI

stress

obesity

The Personal Adjustment Mode is indicated by a diver symbol and plus signs (P0 = a diver, P1 = diver +, or P2 = diver ++). Section 4.3.1.1. ”Al- titude Adjustment and Personal Adjustment Setting” describes how the Personal Mode is adjusted.

This feature should be used to adjust the computer to be more conserva- tive, according to personal preference, by entering the suitable Personal Adjustment Mode with the help of Table 3.5. In ideal conditions, retain the default setting, P0. If conditions are more difficult or other mentioned factors which tend to increase the possibility of DCI exist, select P1 or even the most conservative P2. As a result the dive computer adjusts its mathematical model according to the entered Personal Adjustment Mode, giving shorter no-decompression times (see section 6.1. ”Operat- ing Principles”, Table 6.1 and 6.2).

TABLE 3.5. PERSONAL ADJUSTMENT RANGES

The Vytec also allows experienced divers who are willing to accept a greater level of risk to adjust the RGBM model. The default setting is RGB100 which gives full (100%) RGBM effect. Suunto strongly advises to use full RGBM effect. Statistically very experienced divers have less incidents with DCI. The reason for this is unknown, but it is possible that some level of physiological and or psychological accommodation can take place when you are very experienced as a diver. Thus for certain divers and diving conditions you may want to set attenuated (50%) RGBM

41

Image 43
Contents Suunto Vytec DS Guide Reference Quick COPYRIGHT, Trademark and Patent Notice Definition of WARNINGS, Cautions and NotesPrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Suunto RGBM/ Deep Stop Algorithm IntroductionEmergency Ascents Safety PrecautionsFunctions Getting AcquaintedDive Computer Limitations NitroxPush Buttons Making the Vytec personalWater Contacts Press the Smart Mode buttonInstalling the Transmitter Wireless Cylinder Pressure TransmissionPairing and Code Selection Transmission Data Lobt Pressure Transmission Related DisplaysSetc FailBefore Diving Diving with the VytecActivation and Prechecks Battery Power Indicator Battery IndicationLowbat + Battery Power IndicatorDive Planning Plan Wireless Transmitter Battery IndicatorDive Numbering Shown During Dive Planning Safety Stops User Definable Functions and AlarmsRecommended Safety Stop Diving display. Pres- ent depth is 19.3 m Mandatory Safety StopDeep Stops Diving in AIR ModeBasic Dive Data Cylinder Pressure Data BookmarkConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorDecompression dives Safety Stops and Deep StopsCEILING, Ceiling ZONE, Floor Decompression Range Display Above the Floor Display below the FloorDisplay AT the Ceiling Zone Display Above the Ceiling Diving in Nitrox Mode 3.4.1. Before DivingOxygen Displays Default Nitrox Settings22. Diving in Nitrox mode. The O2% is set to 32% OLF Oxygen Limit FractionGas Change, Multiple Breathing Gas Mixes Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Separated by a colon, telling Dive NumberingFlying After Diving Three double beeps occur, when Audible and Visual AlarmsSet oxygen partial pressure limit is exceeded. The maximum Oxygen Alarms in Nitrox ModeAltitude Adjustment Ranges High Altitude Dives and Personal AdjustmentAltitude Adjustment Personal AdjustmentPersonal Adjustment Ranges Rgbm Model Settings Error ConditionsOmitted Decompression USE of the Menu Based Functions Menu Based ModesList of the Menu Based Modes Exit / QuitLogbook and Dive Profile Memory 1 Logbook Memories and Data Transfer 1 MemoryI, main display Fig III Fig Dive Profile Memory Prof Dive History Memory 2 HistoryData Transfer and PC-Interface 3 TR-PC Dive Simulator 1 Simdive Simulation Mode 2 SimulSET Modes 3 SET Dive Planning Simulator 2 SimplanDive Parameter Settings 1 SET Dive Maximum Depth Alarm Setting 3 MAX Dpth Dive Time Alarm Setting 2 d AlarmNitrox/Oxygen Settings 4 Nitrox Adjusting Time 1 AdJ Time Setting Time 2 SET TimeBacklight Setting 1 Light Adjusting Date 2 AdJ DateAdjusting Daily Alarm 3 T Alarm Setting Preferences 3 SET PrefDive Computer Model Setting 5 Model Dive Computer Units Setting 2 UnitsWireless Transmission Settings 3 HP Profile Sample Rate Setting 4 RECWater Contacts and Push Buttons Care and MaintenanceImportant Information Care of Your Dive ComputerWater Resistance Inspection MaintenanceBattery KIT Battery Replacement 5.5.1. Computer batteryTools Required Battery ReplacementPage Opening of the securing ring Wireless Transmitter Battery ReplacementTools Required Transmitter Battery ReplacementOperating Principles Technical DescriptionNO-DECOMPRESSION Limits Altitude Diving Surface Intervals Suunto Reduced Gradient Bubble Model RgbmOxygen Exposure Transmitter Technical SpecificationOther displays Battery Vytec Warranty System Requirements SUUNTOSPORTS.COMCommunities My SuuntoGetting Started Sport ForumsGlossary EAN EADOLF NitroxNoaa No DEC TimeRgbm PO2Surf Time Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08