Suunto VYTEC DS manual Dive Planning Simulator 2 Simplan, SET Modes 3 SET

Page 53

multiple gas mixes are set they will be changed as soon as allowed maximum depth is reached upon ascent and in the order of: MIX1, MIX2 and MIX3

To enter the Dive Simulator mode select MODE- 2 SIMUL- 1 SIMDIVE (Fig. 4.17. and 4.18.).

4.2.2.Dive Planning Simulator [2 SIMPLAN]

The Dive Planning Simulator mode shows you the present no-decompression limits. In this mode, you are also able to add the desired surface interval increment to present surface interval time, which allows you to plan your dives in advance.

This mode is also used to add the desired surface intervals for dive simulations. Add the desired surface interval increment to present surface interval by pressing the arrow down (TIME) and arrow up (PLAN) buttons.

NOTE! This display is only shown for repeti- tive dives.

To enter the Dive Planning Simulator mode select MODE- 2 SIMUL- 2 SIMPLAN (Fig. 4.19.).

NOTE! The Dive Planning Simulator mode is disabled in Gauge mode and in Error mode (see section 3.9. ”Error Conditions”).

SURF

OK

TIME

Fig. 4.20. Selected Dive Planning Simulator mode. Add desired surface interval incre- ment (to present shown surface interval) by pressing TIME and PLAN buttons. This display is only shown

for repetitive dives.

DIVE

MAX

QUIT

NO DEC TIME

Fig. 4.21. Dive Planning Simulation.

4.3. SET MODES [3 SET]

The Set Modes (Fig. 4.22.) are divided into three submodes for setting the dive-related parameters, time-related parameters and your personal preferences.

QUIT

OPTIONS

Fig. 4.22. Setting Op- tions. [3 SET].

51

Image 53
Contents Suunto Vytec DS Guide Reference Quick COPYRIGHT, Trademark and Patent Notice Definition of WARNINGS, Cautions and NotesPrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Suunto RGBM/ Deep Stop Algorithm IntroductionEmergency Ascents Safety PrecautionsDive Computer Limitations Getting AcquaintedNitrox FunctionsPush Buttons Making the Vytec personalWater Contacts Press the Smart Mode buttonInstalling the Transmitter Wireless Cylinder Pressure TransmissionPairing and Code Selection Transmission Data Setc Pressure Transmission Related DisplaysFail LobtActivation and Prechecks Diving with the VytecBefore Diving Battery Power Indicator Battery IndicationLowbat + Battery Power IndicatorDive Numbering Shown During Dive Planning Wireless Transmitter Battery IndicatorDive Planning Plan Recommended Safety Stop User Definable Functions and AlarmsSafety Stops Diving display. Pres- ent depth is 19.3 m Mandatory Safety StopBasic Dive Data Diving in AIR ModeDeep Stops Cylinder Pressure Data BookmarkConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorDecompression dives Safety Stops and Deep StopsCEILING, Ceiling ZONE, Floor Decompression Range Display AT the Ceiling Zone Display below the FloorDisplay Above the Floor Display Above the Ceiling Diving in Nitrox Mode 3.4.1. Before DivingOxygen Displays Default Nitrox Settings22. Diving in Nitrox mode. The O2% is set to 32% Gas Change, Multiple Breathing Gas Mixes Oxygen Limit FractionOLF Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Separated by a colon, telling Dive NumberingFlying After Diving Three double beeps occur, when Audible and Visual AlarmsSet oxygen partial pressure limit is exceeded. The maximum Oxygen Alarms in Nitrox ModeAltitude Adjustment High Altitude Dives and Personal AdjustmentPersonal Adjustment Altitude Adjustment RangesPersonal Adjustment Ranges Omitted Decompression Error ConditionsRgbm Model Settings USE of the Menu Based Functions Menu Based ModesList of the Menu Based Modes Exit / QuitLogbook and Dive Profile Memory 1 Logbook Memories and Data Transfer 1 MemoryI, main display Fig III Fig Dive Profile Memory Prof Dive History Memory 2 HistoryData Transfer and PC-Interface 3 TR-PC Dive Simulator 1 Simdive Simulation Mode 2 SimulSET Modes 3 SET Dive Planning Simulator 2 SimplanDive Parameter Settings 1 SET Dive Nitrox/Oxygen Settings 4 Nitrox Dive Time Alarm Setting 2 d AlarmMaximum Depth Alarm Setting 3 MAX Dpth Adjusting Time 1 AdJ Time Setting Time 2 SET TimeAdjusting Daily Alarm 3 T Alarm Adjusting Date 2 AdJ DateSetting Preferences 3 SET Pref Backlight Setting 1 LightWireless Transmission Settings 3 HP Dive Computer Units Setting 2 UnitsProfile Sample Rate Setting 4 REC Dive Computer Model Setting 5 ModelImportant Information Care and MaintenanceCare of Your Dive Computer Water Contacts and Push ButtonsWater Resistance Inspection MaintenanceBattery KIT Battery Replacement 5.5.1. Computer batteryTools Required Battery ReplacementPage Opening of the securing ring Wireless Transmitter Battery ReplacementTools Required Transmitter Battery ReplacementNO-DECOMPRESSION Limits Technical DescriptionOperating Principles Altitude Diving Surface Intervals Suunto Reduced Gradient Bubble Model RgbmOxygen Exposure Transmitter Technical SpecificationOther displays Battery Vytec Warranty System Requirements SUUNTOSPORTS.COMCommunities My SuuntoGetting Started Sport ForumsGlossary EAN EADNoaa NitroxNo DEC Time OLFSurf Time PO2Rgbm Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08