Suunto VYTEC DS manual AT the Surface 3.6.1. Surface Interval

Page 37

Tank pressure and ascent rate indicator are also displayed during the dive (Fig. 3.28.). Remaining Air Time, temperature and current time are shown in the alternative display when the TIME button is pressed.

NOTE! If you dive with the Gauge mode, it is not possible to change between the modes within 48 hours.

3.6. AT THE SURFACE 3.6.1. Surface Interval

An ascent to any depth shallower than 1.2 m [4 ft] will cause the DIVING display to be replaced by the SURFACE display, giving the following information (Fig. 3.29.):

maximum depth of last dive in me- ters [ft]

present depth in meters [ft]

no-flying warning indicated by an air- plane icon (Table 3.3)

Altitude Adjustment setting

Personal Adjustment setting

Diver attention symbol indicates attenuated RGBM model has been set

Flashing Diver attention symbol indicates surface interval time should be prolonged (Table 3.3)

STOP label for 5 min, if the Mandatory Safety Stop was violated

Er, if the decompression ceiling was violated (= Error Mode) (Fig. 3.32, Table 3.3)

Cylinder pressure in bars [psi] (if “on”, if “off” temperature is shown)

dive time of last dive in minutes, shown as DIVE TIME.

 

m

 

MAX

bar

DIVE TIME

Fig. 3.28. Diving in Gauge mode. Current dive time is 30 minutes 21 seconds.

 

m

 

MAX

NO

 

bar

DIVE TIME

Fig. 3.29. Surface dis- play. You have surfaced from a 18 minute dive, which maximum depth was 20.0 m [66 ft]. The present depth is 0.0 m [0 ft].Airplane symbol indicates that you should not fly and blinking Diver Attention Symbol indicates that you should prolong your surface interval time because of excess micro-bubbles.

35

Image 37
Contents Suunto Vytec DS Guide Reference Quick COPYRIGHT, Trademark and Patent Notice Definition of WARNINGS, Cautions and NotesPrEN Page Page Page Table of Contents AIR/NITROX/GAUGE Suunto RGBM/ Deep Stop Algorithm IntroductionEmergency Ascents Safety PrecautionsDive Computer Limitations Getting AcquaintedNitrox FunctionsPush Buttons Making the Vytec personalWater Contacts Press the Smart Mode buttonInstalling the Transmitter Wireless Cylinder Pressure TransmissionPairing and Code Selection Transmission Data Setc Pressure Transmission Related DisplaysFail LobtBefore Diving Diving with the VytecActivation and Prechecks Battery Power Indicator Battery IndicationLowbat + Battery Power IndicatorDive Planning Plan Wireless Transmitter Battery IndicatorDive Numbering Shown During Dive Planning Safety Stops User Definable Functions and AlarmsRecommended Safety Stop Diving display. Pres- ent depth is 19.3 m Mandatory Safety StopDeep Stops Diving in AIR ModeBasic Dive Data Cylinder Pressure Data BookmarkConsumed Bottom Time CBT Ascent Rate Indicator Ascent Rate IndicatorDecompression dives Safety Stops and Deep StopsCEILING, Ceiling ZONE, Floor Decompression Range Display Above the Floor Display below the FloorDisplay AT the Ceiling Zone Display Above the Ceiling Diving in Nitrox Mode 3.4.1. Before DivingOxygen Displays Default Nitrox Settings22. Diving in Nitrox mode. The O2% is set to 32% OLF Oxygen Limit FractionGas Change, Multiple Breathing Gas Mixes Diving in Gauge Mode AT the Surface 3.6.1. Surface Interval Separated by a colon, telling Dive NumberingFlying After Diving Three double beeps occur, when Audible and Visual AlarmsSet oxygen partial pressure limit is exceeded. The maximum Oxygen Alarms in Nitrox ModeAltitude Adjustment High Altitude Dives and Personal AdjustmentPersonal Adjustment Altitude Adjustment RangesPersonal Adjustment Ranges Rgbm Model Settings Error ConditionsOmitted Decompression USE of the Menu Based Functions Menu Based ModesList of the Menu Based Modes Exit / QuitLogbook and Dive Profile Memory 1 Logbook Memories and Data Transfer 1 MemoryI, main display Fig III Fig Dive Profile Memory Prof Dive History Memory 2 HistoryData Transfer and PC-Interface 3 TR-PC Dive Simulator 1 Simdive Simulation Mode 2 SimulSET Modes 3 SET Dive Planning Simulator 2 SimplanDive Parameter Settings 1 SET Dive Maximum Depth Alarm Setting 3 MAX Dpth Dive Time Alarm Setting 2 d AlarmNitrox/Oxygen Settings 4 Nitrox Adjusting Time 1 AdJ Time Setting Time 2 SET TimeAdjusting Daily Alarm 3 T Alarm Adjusting Date 2 AdJ DateSetting Preferences 3 SET Pref Backlight Setting 1 LightWireless Transmission Settings 3 HP Dive Computer Units Setting 2 UnitsProfile Sample Rate Setting 4 REC Dive Computer Model Setting 5 ModelImportant Information Care and MaintenanceCare of Your Dive Computer Water Contacts and Push ButtonsWater Resistance Inspection MaintenanceBattery KIT Battery Replacement 5.5.1. Computer batteryTools Required Battery ReplacementPage Opening of the securing ring Wireless Transmitter Battery ReplacementTools Required Transmitter Battery ReplacementOperating Principles Technical DescriptionNO-DECOMPRESSION Limits Altitude Diving Surface Intervals Suunto Reduced Gradient Bubble Model RgbmOxygen Exposure Transmitter Technical SpecificationOther displays Battery Vytec Warranty System Requirements SUUNTOSPORTS.COMCommunities My SuuntoGetting Started Sport ForumsGlossary EAN EADNoaa NitroxNo DEC Time OLFRgbm PO2Surf Time Tissue group Disposal of the Device TIME-KEEPING and STAND-BY Mode Page Page Made in Finland Suunto Oy 01 / 2004, 08