1.Select a suitable location for the HHM. Environmental specifications are listed on page 1-5. The location must have 115 VAC or 230 VAC power.

2.Cut an opening 3.75I(9.53cm) wide x 8I(20.32cm) high in the panel. Drill four mounting holes as shown below.

4.38in

(11.13cm)

3.75in

(9.53cm)

Cutout

1.00in (2.54cm)

6.00in

(15.24cm)

1.00in (2.54cm)

3. Attach the bracket to the HHM with the screws, washers, and lockwashers provided.

(4) holes for mounting on panel

(2) holes for mounting to back of Hand-held Monitor

4.Using appropriate hardware (not provided), mount the HHM and bracket in the cutout.

5.Connect the power cord to the HHM, and connect the signal cable to the connector.