2

Permanent Installation

If the Hand-held Monitor is to be installed using the metal bracket provided, follow the instructions below. Do not install the HHM yet if it will be used to configure I/O blocks.

The mounting bracket provided can be used to install the Hand-held Monitor behind a panel. You will need to make a cutout in the panel for the HHM (see next page).

You will also need to install a connector for the Hand-held Monitor within reach of the HHM's cable. The extra D-shell connector provided with the Hand-held Monitor requires a panel cutout, with the bus cable and Hand-held Monitor located on the opposite sides of the panel (see page 2-8).

An optional panel-mountable or DIN rail-mountable connector is also available. It does not require a cutout. See page 2-9 for details.

Back of HHM

Bracket

To Power Source

Behind Panel

Optional HHM

Connector

Bus In

Bus Out

Configuring a Permanently-installed HHM

Ordinarily, a Hand-held Monitor installed on a panel serves as an operator station. Its configuration may be different from that of a portable HHM.

HIts Device Number must be changed from 0 to some other number.

HAutomatic shutoff may be disabled.

HI/O block configuration and other features may also be disabled.

After the HHM is configured, its keyswitch should be placed in MON position, and the key removed.