Miele G 7824, G 7823 operating instructions Run the reactivation programme, Then

Page 18

Water softener softener (Optional)

Run the reactivation programme

￿Close the door.

￿Open the stopcocks.

￿Select the REACTIVATION programme.

The programme will run automatically.

Then:

￿Switch off the machine.

￿Carefully unscrew the salt container, making sure any water pressure still remaining can depressurise. Do not use force!

If the container will not come off manually please contact the Miele Service Department.

￿Replace the plastic cap.

￿Push the mobile unit back into the cabinet.

￿Turn off the stopcocks.

￿Empty the salt container. Do not empty it into the wash cabinet.

￿Rinse the salt container and filter insert with clean water.

The water pressure (flow pressure at the take off point) must be at least 100 kPa (1 bar).

If it is below100 kPa (1 bar) or if it fluctuates a lot, the water softener will not work properly. After reactivation, salt remains may still be found in the salt container.

To use up salt remains and to rinse out the water softener, the REACTIVATION programme must be carried out again.

18

Image 18
Contents Washer-disinfector G 7823 / G Contents Contents Correct application Page Page Using accessories Symbols on the appliance Disposing of your old machineIntended Use Examples of application areasUnclean side Guide to the machineGuide to the machine Clean side G 7824 only Controls DisplayCursor button right Moves the cursor to the right Door switch Start buttonService interface Programme selector Minus buttonSetting the water softener Water softener softener OptionalReactivation display Reactivating the water softener Water softener softener Optional Run the reactivation programme ThenAutomatic mobile unit recognition Optional Mobile unit coding Setting mobile unit coding Mobile unit coding stripSet the programme place coding Areas of application Protein testAt the end of each programme Loading the machine Preparing the loadUnloading instruments Surgical instruments OP Ophthalmology Anaesthetic instruments AN Baby bottles BC Loading in an EBottom level with 3 x E Frame Operating theatre shoes OS Transfer trolley for loading and unloading the machine Areas of application General notes Problem How to resolve it Chemical processes and technologyChemical agents Problem How to resolve it Chemical processes and technology Soiling Problem How to resolve it Chemical processes and technology Oxivario kit Dispensing liquid chemical agentsAdditional optional DOS modules Orthovario kitPreparing the DOS dispensers Fill the containers with the relevant agentDispensing liquid chemical agents External Dispensing systems Dispensing system maintenanceVenting the dispensing system Every 12-18 monthsOperation Operating levels Selecting or changing your own codeStarting a programme Fixed programmeFree programme selection Programme sequence AWK Automatic mobile unit recognitionSwitching off Cancelling a programmeOperating levels B or D Interrupting a programme Data transfer Maintenance Periodic checksProcess validation Routine checksCleaning the filters in the wash cabinet Cleaning the coarse filterCleaning the coarse, flat and micro-fine filters Cleaning the spray arms Cleaning the wash cabinet Cleaning the control panelCleaning the front of the machine Cleaning the door sealsMobile units, modules and inserts Printer optional Renewing the paper rollRenewing the colour cassette After sales service Converting the type of heating Electrical connection Plumbing Technical data Optional extras Optional extrasSpecial processes Oxivario and Orthovario Description of the machineAreas of application Connecting the H2O2 solution container Disposal of your old machine Page 0366