Miele G 7824, G 7823 operating instructions Correct application

Page 4

Warning and safety instructions

This appliance complies with all relevant legal safety requirements. Please note that incorrect use can lead to personal injury and damage to property.

To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before starting to use it. Keep these instructions in a safe place for reference, and pass them on to any future user.

Correct application

￿This washer-disinfector is designed for use with the applications described in these Operating Instructions only.

Alterations or conversions to the machine, or using it for purposes other than those for which it was designed, are not permitted and could be dangerous.

This machine must only be used for cleaning and disinfecting instruments or medical devices if the manufacturer has stated that they are suitable for machine processing. Manufacturer's cleaning and maintenance instructions for instruments etc. must also be observed.

Miele cannot be held liable for damage caused by improper or incorrect use or operation of the machine.

￿This machine is intended for indoor use only.

￿This machine is not designed for use in mobile installations unless a risk assessment of the installation has been carried out by a suitably qualified engineer.

Please pay attention to the following notes to avoid injury and damage.

￿This machine should be commissioned and then maintained by a Miele authorised and trained service technician only. A Miele service contract is recommended to ensure compliance with GLP Guidelines and the Medical Devices Directive. Unauthorised repairs could be dangerous, for which the manufacturer cannot be held liable.

￿Do not install the machine in an area where there is any danger of explosion or of freezing conditions.

￿The electrical safety of this machine can only be guaranteed if connected to a correctly installed earthing system on site. It is most important that this basic safety requirement is present and tested regularly, and where there is any doubt the on-site electrical system should be inspected by a qualified electrician.

The manufacturer cannot be held liable for damage or injury caused by the lack of or inadequacy of an effective earthing system (e.g. electric shock).

￿A damaged or leaking machine

could be dangerous and compromise your safety. Disconnect the machine from the mains immediately and call the Miele Service Department.

￿Personnel operating the appliance should be trained regularly. Untrained personnel must not be allowed access to the machine or its controls.

4

Image 4
Contents Washer-disinfector G 7823 / G Contents Contents Correct application Page Page Using accessories Symbols on the appliance Disposing of your old machineIntended Use Examples of application areasUnclean side Guide to the machineGuide to the machine Clean side G 7824 only Controls DisplayDoor switch Start button Service interface Programme selectorCursor button right Moves the cursor to the right Minus buttonWater softener softener Optional Setting the water softenerReactivation display Reactivating the water softener Water softener softener Optional Run the reactivation programme ThenAutomatic mobile unit recognition Optional Mobile unit coding Setting mobile unit coding Mobile unit coding stripSet the programme place coding Protein test Areas of applicationAt the end of each programme Preparing the load Loading the machineUnloading instruments Surgical instruments OP Ophthalmology Anaesthetic instruments AN Loading in an E Baby bottles BCBottom level with 3 x E Frame Operating theatre shoes OS Transfer trolley for loading and unloading the machine Areas of application General notes Problem How to resolve it Chemical processes and technologyChemical agents Problem How to resolve it Chemical processes and technology Soiling Problem How to resolve it Chemical processes and technology Dispensing liquid chemical agents Additional optional DOS modulesOxivario kit Orthovario kitPreparing the DOS dispensers Fill the containers with the relevant agentDispensing liquid chemical agents Dispensing system maintenance Venting the dispensing systemExternal Dispensing systems Every 12-18 monthsOperation Operating levels Selecting or changing your own codeFixed programme Starting a programmeFree programme selection Programme sequence AWK Automatic mobile unit recognitionCancelling a programme Switching offOperating levels B or D Interrupting a programme Data transfer Maintenance Periodic checksProcess validation Routine checksCleaning the filters in the wash cabinet Cleaning the coarse filterCleaning the coarse, flat and micro-fine filters Cleaning the spray arms Cleaning the control panel Cleaning the front of the machineCleaning the wash cabinet Cleaning the door sealsMobile units, modules and inserts Renewing the paper roll Printer optionalRenewing the colour cassette After sales service Converting the type of heating Electrical connection Plumbing Technical data Optional extras Optional extrasSpecial processes Oxivario and Orthovario Description of the machineAreas of application Connecting the H2O2 solution container Disposal of your old machine Page 0366