Maintenance

Cleaning the filters in the wash cabinet

The filters in the base of the wash cabinet are designed to prevent coarse soiling getting into the circulation system.

A build-up of coarse soiling can cause the filters to clog up. They should, therefore, be checked daily and cleaned if necessary.

￿This machine must not be used without all the filters in place.

￿Watch out for glass splinters, needles etc. which could cause injury.

Cleaning the coarse filter

￿Press the two lugs together, remove and clean the coarse filter.

￿Put the clean filter back in position and press until it clicks in place.

51

Image 51
Contents Washer-disinfector G 7823 / G Contents Contents Correct application Page Page Using accessories Disposing of your old machine Symbols on the applianceExamples of application areas Intended UseGuide to the machine Unclean sideGuide to the machine Clean side G 7824 only Display ControlsMinus button Door switch Start buttonService interface Programme selector Cursor button right Moves the cursor to the rightSetting the water softener Water softener softener OptionalReactivation display Reactivating the water softener Water softener softener Optional Then Run the reactivation programmeAutomatic mobile unit recognition Optional Mobile unit coding Mobile unit coding strip Setting mobile unit codingSet the programme place coding Areas of application Protein testAt the end of each programme Loading the machine Preparing the loadUnloading instruments Surgical instruments OP Ophthalmology Anaesthetic instruments AN Baby bottles BC Loading in an EBottom level with 3 x E Frame Operating theatre shoes OS Transfer trolley for loading and unloading the machine Areas of application Chemical processes and technology General notes Problem How to resolve itChemical agents Problem How to resolve it Chemical processes and technology Soiling Problem How to resolve it Chemical processes and technology Orthovario kit Dispensing liquid chemical agentsAdditional optional DOS modules Oxivario kitFill the containers with the relevant agent Preparing the DOS dispensersDispensing liquid chemical agents Every 12-18 months Dispensing system maintenanceVenting the dispensing system External Dispensing systemsOperation Selecting or changing your own code Operating levelsStarting a programme Fixed programmeFree programme selection AWK Automatic mobile unit recognition Programme sequenceSwitching off Cancelling a programmeOperating levels B or D Interrupting a programme Data transfer Periodic checks MaintenanceRoutine checks Process validationCleaning the coarse filter Cleaning the filters in the wash cabinetCleaning the coarse, flat and micro-fine filters Cleaning the spray arms Cleaning the door seals Cleaning the control panelCleaning the front of the machine Cleaning the wash cabinetMobile units, modules and inserts Printer optional Renewing the paper rollRenewing the colour cassette After sales service Converting the type of heating Electrical connection Plumbing Technical data Optional extras Optional extrasDescription of the machine Special processes Oxivario and OrthovarioAreas of application Connecting the H2O2 solution container Disposal of your old machine Page 0366