Miele G 7823, G 7824 Preparing the DOS dispensers, Fill the containers with the relevant agent

Page 39

Dispensing liquid chemical agents

Preparing the DOS dispensers

The agents can be filled into 5 l plastic containers, which are colour coded for the relevant dispensing system.

When first commissioning, or when the message FILL DOS 1 CONTAINER and/or FILL DOS 2, 3 or 4 CONTAINER flashes in the display after switching on or at the end of a programme, replace the storage containers with new ones, or refill them with the relevant agent.

If the message CHECK DISPENSING SYSTEM 1 and/or CHECK DISPENSING SYSTEM 2, 3 or 4 flashes in the display, check the storage containers, dispensing tubes and hoses. Then replace the storage containers with new ones, or refill them with the relevant agent.

The programme will stop automatically.

When first commissioning or when the message CHECK DISPENSING SYSTEM... appears, start the DOS-FILL Programme to vent the dispensing system (see "Venting the dispensing system").

￿Take great care when handling liquid agents and additives. These may contain irritant or corrosive ingredients.

Please follow the manufacturer’s safety instructions.

Wear protective gloves and goggles.

Fill the containers with the relevant agent

￿Switch the machine off using the master switch.

￿Lift the service panel up and then drop it forwards and release it from its lower brackets.

￿Pull open the drawer to the right of the service panel to access the liquid supply containers.

￿Take the storage containers out, open them and fill with the agent required, (observe the colour code).

￿Set the service panel onto the lower bracket and then raise it upwards and pressing against the washer-disinfector lower it into position.

39

Image 39
Contents Washer-disinfector G 7823 / G Contents Contents Correct application Page Page Using accessories Disposing of your old machine Symbols on the applianceExamples of application areas Intended UseGuide to the machine Unclean sideGuide to the machine Clean side G 7824 only Display ControlsMinus button Door switch Start buttonService interface Programme selector Cursor button right Moves the cursor to the rightSetting the water softener Water softener softener OptionalReactivation display Reactivating the water softener Water softener softener Optional Then Run the reactivation programmeAutomatic mobile unit recognition Optional Mobile unit coding Mobile unit coding strip Setting mobile unit codingSet the programme place coding Areas of application Protein testAt the end of each programme Loading the machine Preparing the loadUnloading instruments Surgical instruments OP Ophthalmology Anaesthetic instruments AN Baby bottles BC Loading in an EBottom level with 3 x E Frame Operating theatre shoes OS Transfer trolley for loading and unloading the machine Areas of application Chemical processes and technology General notes Problem How to resolve itChemical agents Problem How to resolve it Chemical processes and technology Soiling Problem How to resolve it Chemical processes and technology Orthovario kit Dispensing liquid chemical agentsAdditional optional DOS modules Oxivario kitFill the containers with the relevant agent Preparing the DOS dispensersDispensing liquid chemical agents Every 12-18 months Dispensing system maintenanceVenting the dispensing system External Dispensing systemsOperation Selecting or changing your own code Operating levelsStarting a programme Fixed programmeFree programme selection AWK Automatic mobile unit recognition Programme sequenceSwitching off Cancelling a programmeOperating levels B or D Interrupting a programme Data transfer Periodic checks MaintenanceRoutine checks Process validationCleaning the coarse filter Cleaning the filters in the wash cabinetCleaning the coarse, flat and micro-fine filters Cleaning the spray arms Cleaning the door seals Cleaning the control panelCleaning the front of the machine Cleaning the wash cabinetMobile units, modules and inserts Printer optional Renewing the paper rollRenewing the colour cassette After sales service Converting the type of heating Electrical connection Plumbing Technical data Optional extras Optional extrasDescription of the machine Special processes Oxivario and OrthovarioAreas of application Connecting the H2O2 solution container Disposal of your old machine Page 0366